Ground, rock and buried pipes

Soil and rock have diffusivities near 1 mm²/s, with sandy and dry soils often a little lower and solid rock a little higher. Geotechnical and ground-source heat references may give the value in mm²/s, in m²/s or in cm²/s, and a person comparing sources has to line them up. This page divides the mm²/s value by 100. A ground value of 1 mm²/s becomes 0.01 cm²/s, and 0.5 mm²/s becomes 0.005 cm²/s. The numbers are small in any unit, which says that heat moves slowly through the ground, and that fact is why a pipe or cable buried a meter or so down feels little of the daily temperature swing. A trench dug for a water line shows the same thing: the soil a meter below the surface stays cool on a hot afternoon.

Why the factor is 100

A centimeter is 10 mm, and the area carries the square, so one cm² is 100 mm². Both units use seconds, so no time factor enters: cm²/s = mm²/s × 0.01. The prefixes are defined in the SI Brochure and in NIST SP 811. The page opens with 10 mm²/s and returns 0.1 cm²/s. Dividing by 10 instead of 100 is a frequent slip, and it makes a ground temperature wave seem to travel about 3 times deeper than it does, since depth scales with the square root of diffusivity.

How deep a temperature swing goes

The depth at which a periodic surface temperature swing falls to about 1/e of its surface amplitude is the square root of diffusivity times the period divided by pi. For 1 mm²/s, which is 10^-6 m²/s, and a period of one day, 86,400 seconds, the depth is the square root of 10^-6 × 86,400 / 3.1416, about 0.166 m. For a one-year period of about 3.156 × 10^7 seconds, it is about 3.17 m. These are illustrative figures for a uniform soil. They explain why frost depth and buried pipe depth are specified in tens of centimeters to a meter or more, and why a basement stays near the annual mean temperature.

Value of the cm²/s form

Handbooks from the CGS era and some building-physics notes give diffusivity in cm²/s, where concrete is about 0.005 and rock about 0.01. A reader who compares a table in cm²/s with a field report in mm²/s has to divide or multiply by 100 for each row, and doing it for twenty rows by hand is where slips occur. The page does this and keeps the unit labels visible, so a number such as 0.01 cm²/s cannot be confused with 0.01 mm²/s, which would be a hundred times smaller. When a source omits the unit, the magnitude helps: a soil value of 1 suggests mm²/s, and a value of 0.01 suggests cm²/s.

Metals and the same conversion

The same division applies to metals. Copper at 111 mm²/s is 1.11 cm²/s, aluminum at 97 mm²/s is 0.97, and stainless steel at 4 mm²/s is 0.04. A designer who gets a laser-flash report in mm²/s and a legacy table in cm²/s can place both on one scale. A result near 55.5 mm²/s from a sample report becomes 0.555 cm²/s, which falls between steel and aluminum. Always record the temperature of a measured value, because metals change with temperature, and a room-temperature table value does not apply to a hot part. If a report gives a curve against temperature, convert the points you need and keep the temperature next to each.

Small values and exponent entry

Soils and insulation produce numbers like 0.4 or 0.0008 in mm²/s. Enter them as decimals or in exponent form, and check that the answer has the expected magnitude: 0.4 mm²/s becomes 0.004 cm²/s. Spreadsheets may drop a trailing digit when a cell is formatted with too few decimals, so format results in scientific notation if values are small. Keep the full precision in the calculation and show only two or three significant digits in a report, since measured diffusivities of soil vary by tens of percent with moisture and compaction.

Moisture changes the number

Soil diffusivity depends strongly on moisture. Dry sand has a lower value than wet sand, and the difference can be large because water increases both conductivity and heat capacity. A single figure from a table is therefore a rough value for a stated state, and design guides usually give ranges. When you convert a range, convert both ends, for example 0.4 to 1.0 mm²/s becomes 0.004 to 0.01 cm²/s, and keep both in your notes. A single converted value hides the spread that matters for a buried pipe or a ground loop. Local test data or a geotechnical report should take priority over a general table.

Small CGS decimals scaled up by 100

Select cm²/s as the source and mm²/s as the target to multiply by 100, which turns the small decimals of a CGS table into numbers of a readable size. A value of 0.005 cm²/s returns 0.5 mm²/s, and 1.11 returns 111. A round trip of 10 mm²/s to 0.1 cm²/s and back should return 10, and the page displays up to twelve significant digits, so a difference in the last digit is a display effect, and the unit labels on the page make the direction easy to confirm. Labels on the page show the unit names beside the number, which helps you confirm the direction before you copy the result into a report.

Buried lines and local frost rules

The converter restates a number you supply. It does not estimate ground temperatures, size a pipe depth or look up a soil property, and it does not tell thermal diffusivity apart from other quantities that share its dimensions. Use a local source for design values, apply the method of the governing guideline and have significant designs reviewed by a qualified person. For a household project such as a shallow buried line, local frost depth rules and the advice of the installer matter more than any diffusivity figure. The converted number is only as good as the value you started from.