Model inputs and lab reports in four units
Simulation and finite-element software normally expects SI, so m²/s. Laser-flash reports and many materials databases give mm²/s, because the values for ordinary solids land between 0.1 and 100. Older handbooks print cm²/s, and US customary tables use ft²/h. Someone pulling a diffusivity from a lab report to feed a model, or from a US table to check a metric calculation, has to move between these units without slipping a factor in the squared length or the time. This page does that in one step and keeps the full unit label on screen. The common slip is applying a linear factor, 1,000 for millimeters to meters, to a quantity that carries the length squared.
Squared length and per-time factors
Thermal diffusivity is length squared over time, so the length factor is squared. One meter is 1,000 mm, so 1 m²/s is 10^6 mm²/s, and one meter is 100 cm, so 1 m²/s is 10^4 cm²/s. One foot is exactly 0.3048 m, so one square foot is 0.09290304 m², and an hour is 3,600 s, which gives 1 ft²/h = 0.09290304 / 3,600 = 2.58064 × 10^-5 m²/s. The formula for the default is mm²/s = m²/s × 1,000,000. NIST SP 811 lists the foot and the prefixes. All of these factors are defined, and the page adds no rounding before it shows up to twelve significant digits.
A default far above real materials
The page starts with 10 m²/s and returns 10,000,000 mm²/s. No solid has a diffusivity near 10 m²/s. Copper is around 1.1 × 10^-4 m²/s, aluminum near 9.7 × 10^-5, carbon steel in the range of 1.2 × 10^-5 to 1.8 × 10^-5, and water is about 1.4 × 10^-7. So the default checks the arithmetic, and real values need the exponent. Enter 1.11e-4 with m²/s as the source and mm²/s as the target and the answer is 111 mm²/s. If the entry field does not accept e-notation in your browser, type the decimal form 0.000111 instead. Both give the same result.
Water as a worked case
Diffusivity equals conductivity divided by density times specific heat. For water, take 0.6 W/(m·K), 1,000 kg/m³ and 4,180 J/(kg·K), which are round illustrative values. The result is 1.435 × 10^-7 m²/s. In millimeters squared per second that is 0.1435 mm²/s, and in cm²/s it is 0.001435. The same value in US units is 0.00556 ft²/h. A quick time scale for heat to cross a layer is thickness squared over diffusivity. For a 10 mm layer of still water that is 0.0001 divided by 1.435 × 10^-7, which is about 697 seconds, or close to 12 minutes. This is an order-of-magnitude estimate for a still layer, and real water convects.
Metals in a laser-flash report
A laser-flash apparatus measures how fast a pulse of heat crosses a thin disc, and the report prints diffusivity in mm²/s or cm²/s. Aluminum near 97 mm²/s is 0.97 cm²/s, and copper near 111 mm²/s is 1.11 cm²/s. Stainless steel, around 4 mm²/s, becomes 0.04 cm²/s. A technician preparing a comparison table in handbook units can paste the lab values and use the converter for each row. Diffusivity depends on temperature, so a table value labeled 25 °C and a report value measured at 300 °C are different numbers even when the units agree. Record the temperature with each figure before converting it.
Feet per hour in US references
US heat-transfer references and some HVAC and process-engineering tables give diffusivity in ft²/h. A value of 1 ft²/h equals 25.8064 mm²/s, 0.258064 cm²/s and 2.58064 × 10^-5 m²/s. Steel at 0.465 ft²/h therefore corresponds to 12 mm²/s, and air at 0.85 ft²/h is about 21.94 mm²/s. If a table lists ft²/s by mistake or a text prints per day, the conversion changes, and the page covers per hour only. Always read the time unit on a column heading, because the factor between per hour and per second is 3,600 and an unnoticed difference spoils the answer.
Diffusivity is not viscosity
Kinematic viscosity has the same dimensions, length squared over time, and a table of stokes values for fluids uses cm²/s as well. Water has a kinematic viscosity near 1 mm²/s at 20 °C, while its thermal diffusivity is about 0.14 mm²/s, and the ratio of the two, about 7, is the Prandtl number. The page treats the number you enter as thermal diffusivity and keeps the label on the result. It does not convert viscosity, and it does not turn a viscosity into a diffusivity. When a column in a spreadsheet mixes the two, a clear header prevents a physical mistake that no unit conversion can repair.
Choosing the unit for a model or a table
When a team shares a material database, one unit should be chosen for the column and written in its header. For a model in SI, use m²/s and keep exponents, so 1.43e-7 is clear. For a lab sheet, mm²/s keeps values in a readable range. For a US reference, ft²/h matches the printed tables. Convert each source value once and note the original unit beside it, which lets a reviewer check the step. Avoid converting back and forth through several units, since each pass is another chance to mistype a factor. A quick check with a known pair, such as 1 ft²/h equal to 25.8064 mm²/s, confirms that a script or spreadsheet uses the right factor. Spreadsheets also help here: put the factor in its own labeled cell, such as 2.58064E-5 for feet squared per hour to square meters per second, and reference that cell, so a reviewer can see the number and trace it to this page or to a handbook.
Limits when using the result
The page restates a diffusivity you already know. It does not compute the property from conductivity, density and heat capacity, it does not adjust for temperature, and it says nothing about anisotropy, moisture or porosity, which matter for wood, soil, composites and insulation. For a transient heat-flow calculation, take the diffusivity from a source that states the conditions, convert it once, and keep the same unit through the calculation. The result shows twelve significant digits at most, and a measured diffusivity rarely deserves more than three.