Handbook centimeters against datasheet millimeters

Older handbooks print diffusivity in cm²/s, and modern laser-flash reports and many materials databases use mm²/s, because it puts ordinary solids between roughly 0.1 and 100. Someone filling a comparison table, or checking whether a new sample agrees with a reference value, needs both on one scale. This page multiplies cm²/s by 100. Aluminum at 0.97 cm²/s is 97 mm²/s, and a ceramic at 0.12 cm²/s is 12 mm²/s. The numbers in mm²/s are easier to read in a table than decimals such as 0.0012, which is why the unit is popular in instrument output. When the two sources differ by exactly a factor of 100, a unit mismatch is the first suspect. A value near 97 mm²/s is quicker to read and compare than 0.97 cm²/s, and rows of such numbers line up in a table.

Why the factor is 100

One centimeter is 10 mm, and the length in diffusivity is squared, so 1 cm² is 100 mm². The second stays in the denominator on both sides, which keeps the formula at mm²/s = cm²/s × 100. NIST SP 811 and the SI Brochure define the prefixes. A common slip is to multiply by 10, the linear factor, and get a result a tenth of the true size. A second check by units is to picture a square 1 cm on a side. Its area is 10 mm by 10 mm, which is 100 mm², and the time part has not changed, so the factor is the area ratio.

Ten cm²/s as a test value

The default of 10 cm²/s returns 1,000 mm²/s, about nine times the diffusivity of copper, so it is a demonstration. Try values that look like real materials. Copper at 1.11 gives 111 mm²/s, carbon steel at 0.12 gives 12, stainless steel at 0.04 gives 4, and a polymer at 0.001 gives 0.1. If one of these answers is not 100 times the input, the source and target were probably swapped. Because the factor is a power of ten, the digits of the answer match those of the input and only the decimal position moves. That makes a visual check quick: 0.12 and 12 share the digits 1 and 2, and a result such as 1.2 or 120 would point to a slip.

A laser-flash example

In a laser-flash test a thin disc is heated on one face and the rise on the other face is recorded. The half-rise method gives diffusivity as 0.1388 times the squared thickness divided by the time to reach half the maximum rise. For a 2 mm disc with a half-rise time of 10 ms, that is 0.1388 × 4 / 0.01 = 55.52 mm²/s, which equals 0.5552 cm²/s. Reports typically give the mm²/s figure, and a handbook may want the cm²/s one. The unit conversion is the last step. Corrections for heat loss and finite pulse length belong to the instrument software, and the report should state the temperature of the test, since the same sample gives a different value at another temperature.

Reading a table of metals

Suppose a handbook lists copper 1.11, aluminum 0.97, brass 0.34, carbon steel 0.12 and stainless steel 0.04, all in cm²/s. Converting the column gives 111, 97, 34, 12 and 4 mm²/s. In that form, the spread between copper and stainless steel is easy to see, a factor of about 28. This is useful when you decide which material will even out a temperature quickly, for example in a fixture or a mold plate. Values depend on temperature and on alloy details, so use the temperature stated in the table and do not assume a figure holds elsewhere.

Polymers and insulation

Plastics and foams have low diffusivities, usually in the range of 0.05 to 0.2 mm²/s for common polymers, which is 0.0005 to 0.002 cm²/s. A value of 0.001 cm²/s becomes 0.1 mm²/s. In a molding or 3D printing context, this slow diffusion is why a thick part keeps its core hot long after the surface has cooled, and a time scale of thickness squared over diffusivity shows it. For a 5 mm wall with 0.1 mm²/s, that is 25 / 0.1 = 250 seconds, about 4 minutes. The figure is an order of magnitude only and ignores the mold and cooling conditions.

Cleaning a data file column by column

To go from mm²/s to cm²/s, select mm²/s as the source and cm²/s as the target, and the page divides by 100. A value of 4 mm²/s is 0.04 cm²/s, and 111 mm²/s is 1.11 cm²/s. If you are cleaning a data file, convert one known row first and compare it with the table. Keep the unit in the column header, and avoid editing numbers by hand across many rows, since one slip of a decimal point goes unnoticed. The page shows the full unit label on screen for each selection so that the direction is clear before you copy the value.

Choosing which unit to keep in a database

If you maintain a table of materials, pick one unit for storage. Many groups store mm²/s because the values are readable and ordinary solids fall between 0.01 and 150. Others store m²/s to avoid conversions in code. Whatever you choose, convert each incoming value once and keep the original in a separate column, with the source and temperature. A script that reads centimeters in one file and millimeters in another is a typical source of a factor-of-100 error. A test row with 1 cm²/s expected to equal 100 mm²/s, run each time the data is loaded, catches that mistake before it reaches a report.

Reported uncertainty stays with the source

The converter does not measure diffusivity, correct for temperature or judge a material for a job. It also does not distinguish between the thermal quantity and other quantities with the same dimensions, so you must supply the right one. The measured value in a report carries its own uncertainty, often several percent, and the converter adds none and removes none. Cite the original unit and the converted one together when you publish a table, so a reader can check your step.