Cookware cores and plate thickness

Pan makers combine layers because metals differ in how fast they spread heat. Aluminum near 97 mm²/s evens out a hot spot in a fraction of a second across a few millimeters, while stainless steel near 4 mm²/s needs several seconds. A US handbook may list the same metals in ft²/h, and a buyer or engineer who has the metric datasheet needs a conversion. The same need appears for baking sheets, griddles and any product sold with a metric technical sheet in a US market. This page multiplies mm²/s by 0.0387500775. Aluminum becomes 3.7588 ft²/h and stainless steel becomes 0.155 ft²/h. The result is the same property in a different unit, with no change in meaning. Buyers comparing a European pan with a US specification sheet can use the page for exactly this step.

Where 0.03875 comes from

One mm² is 10^-6 m², and a square foot is 0.09290304 m², so one mm² is 1.0764 × 10^-5 ft². Multiplying by 3,600 seconds per hour gives 0.0387500775 ft²/h for each mm²/s. The formula on the page is ft²/h = mm²/s × 0.0387500775002. Because the foot, the hour and the prefix are defined, the factor has no measurement error. NIST SP 811 documents the foot. The factor is below one, so the number shrinks when you go from mm²/s to ft²/h, and a result larger than the input would point to the wrong direction.

Ten mm²/s on the page

The default of 10 mm²/s returns about 0.3875 ft²/h. That sits between steel and concrete in the middle of the range of common solids, so unlike many defaults it is a plausible value, for example for a high-alloy steel or a dense ceramic. Try a few rows to see the scale: 111 mm²/s gives 4.30126 ft²/h, 12 gives 0.465, 0.5 gives 0.019375 and 0.143 gives 0.00554. The span from about 0.005 to about 4.3 covers most solids and liquids, so a result outside it deserves a second look at the input. Foams and gases lie outside this band, since air is near 0.85 and some light foams are near 0.05.

A pan base as a worked comparison

Take an illustrative 5 mm thick pan base. The time for heat to cross it is roughly the squared thickness divided by diffusivity. With aluminum at 97 mm²/s that is 25 / 97 = 0.26 seconds. With stainless steel at 4 mm²/s it is 25 / 4 = 6.25 seconds. In ft²/h the same data read 3.7588 and 0.155, and with the thickness 0.0164 ft the squared value is 0.000269 ft², giving 0.000269 / 0.155 = 0.00174 hours, which is 6.25 seconds again. The agreement confirms the conversion. The estimate ignores the food, the burner and the pan walls, so it only explains why layered bases exist.

Ranking by speed

Placing several materials on the same scale shows the spread, and a conversion table makes it easy to see which sources use which unit. Copper at 111 mm²/s is about nine times faster than steel at 12 mm²/s and about 28 times faster than stainless steel at 4. Concrete at about 0.5 mm²/s is 8 times slower than stainless steel. In ft²/h that spread is 4.3, 0.465, 0.155 and 0.019, and the ratios are unchanged because both columns come from the same factor. This helps when one source is in each unit: you can verify a conversion by checking that the ratios between rows match, not only the individual values.

Precision and rounding

The page shows up to twelve significant digits, such as 0.0554128 for 1.43 mm²/s. Material data seldom deserves more than three digits, and the value usually varies by a few percent between sources and with temperature. Round to the precision of your input when reporting. Keep the full value in a spreadsheet while computing, and format only the displayed cell. If a published table lists 0.0055 for water in ft²/h and the page returns 0.00554 for 0.143 mm²/s, that agreement to two digits is a good result for a property of this kind. Do not chase a match in the fourth digit between sources that measured different samples.

A script check with 0.3875 ft²/h

Select ft²/h as the source and mm²/s as the target to go back. One ft²/h is 25.8064 mm²/s, and 0.155 ft²/h returns about 4 mm²/s. Round trips are the best check of a script: 10 mm²/s to 0.3875 ft²/h and back should return 10 to the displayed digits. If your result is off from expectations by a factor near 3,600 or near 10.76, think about the time unit and the square foot area, which are the two parts of this conversion. The labels on the page repeat the unit names so you can confirm the direction.

Explaining a small gap between two tables

Suppose a US handbook lists stainless steel at 0.15 ft²/h and a supplier sheet gives 4 mm²/s, which the page converts to 0.155 ft²/h. The gap is about 3 percent, and it is well within what different alloys, temperatures and test methods produce. A gap of a factor of 3,600 or 10.76 would be a unit error, while a gap of a few percent usually is not. Applying this rule saves time when you reconcile tables. Convert the supplier value, compare it with the handbook value, and ask whether the difference matches the usual spread for that material. If it does, keep both sources in your notes and use the one that states the grade and temperature.

Naming material grade and temperature with the result

The conversion does not provide a diffusivity for a material, correct for temperature or alloy, or check whether a figure comes from a measurement. Kinematic viscosity shares the dimensions of area over time, so confirm that the value you entered is thermal. For safety-related uses, apply the standard that governs the application, and have the calculations reviewed by a qualified person. The result restates one number in another unit and carries over every uncertainty of the source. When you share the converted value, name the original unit, the temperature and the material grade, so that a reader can retrace the step and compare it with their own table.