Datasheet figures in mm²/s, handbook figures in ft²/h
Modern instrument reports and materials databases list diffusivity in mm²/s, since the values for ordinary solids run from about 0.1 to 150 and read easily. US handbooks and some industry tables still use ft²/h. A person checking a measured value against a published reference, or building a comparison table from both kinds of source, has to bring them together. Doing so with a calculator invites slips, because the foot, the hour and the square all enter. This page multiplies the ft²/h figure by 25.8064. A rough rule is that 1 ft²/h is about 26 mm²/s, so 4.3 ft²/h for copper is 110.97 mm²/s, close to the 111 mm²/s printed in many metric tables.
Building the factor from the definitions
A foot is 304.8 mm, so a square foot is 92,903.04 mm². Dividing by the 3,600 seconds in an hour gives 25.8064 mm²/s. The formula on the page is mm²/s = ft²/h × 25.8064. The arithmetic mixes an area ratio that increases the number and a time ratio that decreases it, and the area effect wins by a factor of about 26. The ratio is defined, with NIST SP 811 as the reference for the foot, so the 12-digit display never hides rounding of the factor itself. The page computes the result from the stored source and target factors and rounds only for display, so a long chain of conversions does not pile up errors. If you see a result below the input, the source and target are in the wrong order. For a table with many rows, the same factor applies to every row, so one confirmed conversion validates the rest.
Ten ft²/h as a check value
The default of 10 ft²/h returns 258.064 mm²/s. That is high next to everyday solids, since copper sits near 111 mm²/s, so the default shows the arithmetic and little more. Use rows from your own table instead. Carbon steel at 0.465 ft²/h comes out at 12 mm²/s, concrete at 0.02 ft²/h at 0.516 mm²/s, and water at 0.00554 ft²/h at 0.143 mm²/s. This list covers three orders of magnitude, so it also helps you feel which materials respond to a temperature change quickly and which slowly. If you convert a whole table, keep the order of the rows, then sort by the new column to see the ranking.
Ranking materials by speed of heating
Diffusivity indicates how fast a temperature disturbance spreads, and in mm²/s the comparison is easy to read. Copper at about 111 mm²/s moves heat roughly nine times faster than steel at 12, and steel is about 23 times faster than concrete at 0.5. The time to even out a temperature across a thickness scales with the square of the thickness divided by diffusivity, so a 10 mm steel plate needs about 100 / 12 = 8.3 seconds, and a 10 mm concrete slab 100 / 0.516 = 194 seconds, in an illustrative estimate. Real parts have surface resistance, so the numbers set a scale and not a prediction.
Reading small numbers
Water-like materials come out as small values in mm²/s, such as 0.143, and polymers fall near 0.1. Water-like materials and polymers sit at the low end of the scale, and metals at the high end. Because the page shows up to twelve significant digits, a result like 0.142967 may appear when you convert 0.00554 ft²/h. Round it to the precision of your source, which is usually two or three digits. Reporting 0.143 mm²/s is honest, while 0.142967 suggests precision that the original table did not have. In a spreadsheet, keep the full value in the calculation and format the displayed cell to three significant digits. The same rule applies to every value in this family: show only the digits that the source supports.
Going back to ft²/h
Choose mm²/s as the source and ft²/h as the target to return to US units. A value of 111 mm²/s gives 4.30126 ft²/h, and 0.143 mm²/s gives about 0.005541 ft²/h. The reverse factor is 0.0387500775, which is the inverse of 25.8064, and a value of 1 mm²/s is therefore a little under four hundredths of a square foot per hour. A convenient test of any script is that 25.8064 mm²/s returns exactly 1 ft²/h to the displayed digits. If the reverse result differs by more than rounding, check whether a time conversion, 3,600, or a length conversion, 304.8, was applied twice or not at all.
Temperature dependence
Table values for diffusivity carry a temperature, commonly room temperature. For metals, the value usually decreases as the metal gets hotter, and for some polymers it changes with crystallinity and moisture. A handbook value at 68 °F and a laser-flash value at 300 °C are not directly comparable, whatever the unit. The converter changes the unit and leaves the number's conditions as they are. Record the temperature and the material grade next to each converted value, because they explain most disagreements between two sources.
Metals in a mold or fixture
Tooling engineers who choose between aluminum and steel for a mold or a fixture often compare diffusivity, since it governs how fast the tool surface recovers after contact with a hot part. Aluminum near 3.8 ft²/h is about 98 mm²/s, and tool steel near 0.3 ft²/h is about 7.7 mm²/s. The ratio is about 12 to 13, and the page makes that comparison direct when one table is in ft²/h and the other in mm²/s. Conductivity, thickness and cooling channels also matter, so diffusivity gives only part of the picture. Treat it as a first screen before a more detailed model, and keep the unit of the original table in your notes.
A restated measurement, not a design review
The page does not estimate diffusivity from conductivity, density and specific heat, does not identify the material and does not assess a design. It also treats the entered number as thermal diffusivity, not as kinematic viscosity, which has the same dimensions. Treat the answer as a restatement of one measurement in another unit. For work that affects safety or compliance, take the property from the document that governs the application and have the calculation reviewed by a qualified person.