Measurement basis
One unit corresponds to 0.0001 m²/s.
Definition conventions
Preserve the thermal meaning when comparing values with the same-looking dimensions.
Conversion method
Multiply cm²/s by 0.0001 for the reference.
Reference equivalent of cm²/s
1 cm²/s = approximately 0.0001 m²/s.
Recorded scale factors: 0.0001 for cm²/s; 1 for m²/s.
Worked example
Known input: 10 cm²/s. Reference equivalent: 0.001 m²/s. The return conversion gives approximately 10 cm²/s.
The calculation applies the squared centimeter factor.
Common reference values
| Input (cm²/s) | Reference equivalent (m²/s) |
|---|---|
| 1 | 0.0001 |
| 5 | 0.0005 |
| 10 | 0.001 |
| 25 | 0.0025 |
| 50 | 0.005 |
| 100 | 0.01 |
Compare one cm²/s with other units
| Target unit | Equivalent of 1 cm²/s | Definition guide |
|---|---|---|
| Square meters per second (m²/s) | 0.0001 | Read definition |
| Square millimeters per second (mm²/s) | 100 | Read definition |
| Square feet per hour (ft²/h) | 3.87500775002 | Read definition |
What a diffusivity of one cm²/s means
Thermal diffusivity, written alpha, tells how fast a temperature change spreads through a material. It equals thermal conductivity divided by the product of density and specific heat capacity, alpha = k / (rho c_p). One square centimeter per second is exactly 10^-4 m²/s and 100 mm²/s. The centimeter-gram-second system used it for decades, and many handbooks and older measurement reports still list diffusivities this way. Copper sits near 1.1 cm²/s, which is among the highest values of common metals. Water at room temperature is near 0.0014 cm²/s, about 800 times lower. The unit is attractive because ordinary solids fall between 0.001 and a few cm²/s.
Where cm²/s values come from
Many diffusivities are measured directly rather than computed from conductivity. The laser flash method, introduced by Parker, Jenkins, Butler and Abbott in 1961, heats the front face of a thin disc with a short pulse and records the temperature rise on the back face. For an idealized adiabatic sample, alpha = 0.1388 L² / t_half, where L is the thickness and t_half is the time to reach half the maximum rise. With L in centimeters and time in seconds the answer is in cm²/s. A 0.2 cm aluminum disc whose rear face reaches half rise in 5.7 ms gives about 0.97 cm²/s. Real instruments add corrections for heat loss and finite pulse length.
Typical magnitudes at about room temperature
Approximate values show the range. Aluminum is about 0.97 cm²/s and copper about 1.1 cm²/s. Stainless steel is near 0.04 cm²/s, and glass is about 0.005 cm²/s. Dry air near 20 C is about 0.2 cm²/s, higher than many solids because its volumetric heat capacity is tiny. Water is about 0.0014 cm²/s. These figures are rounded and drift with temperature and composition, so use a dated source for design work. Diffusivity depends on conductivity and on volumetric heat capacity together, which means a material can have low conductivity and still change temperature quickly if it stores little heat per unit volume.
Conversions to other thermal diffusivity units
The site converters take this unit to square meters per second (multiply by 0.0001), square millimeters per second (multiply by 100) and square feet per hour. The last needs both an area factor and a time factor. One cm²/s multiplied by 3,600 seconds per hour is 3,600 cm²/h, and dividing by the 929.0304 cm² in a square foot gives 3.875008 ft²/h. Taking the aluminum figure of 0.97 cm²/s as an example, it equals 97 mm²/s, 9.7 x 10^-5 m²/s and about 3.759 ft²/h. Going the other way, a handbook value of 0.0143 cm²/s is 1.43 x 10^-6 m²/s. Because the factor is a power of ten for the metric units, the main risk is shifting the decimal the wrong way.
The stokes link and a look-alike quantity
One square centimeter per second is also the stokes, the CGS unit of kinematic viscosity, which describes how fast momentum diffuses in a fluid. Diffusion of heat and diffusion of momentum share the same dimensions, but they are different physical properties. Their ratio is the dimensionless Prandtl number, about 0.7 for air at room temperature and about 7 for water. A table that lists 0.15 cm²/s for a gas could be giving thermal diffusivity, kinematic viscosity or a mass diffusion coefficient. Read the property name in the source before assigning the number to a calculation, because matching units do not prove that the quantities match.
Using alpha to estimate time
Diffusivity turns directly into time estimates. The characteristic time for heat to cross a thickness L is of the order of L² / alpha. For a 1 cm slab of copper with alpha near 1.1 cm²/s this is under a second. A 1 cm stainless steel plate at 0.04 cm²/s needs about 25 seconds, and a 1 cm layer of water, which conducts only by diffusion when it is still, needs about 700 seconds. The estimate scales with the square of thickness, so doubling the wall quadruples the time. These are order-of-magnitude figures that ignore boundary resistance, convection and the exact shape, and detailed work uses the Fourier number or a numerical model.
Where you see the unit in practice
Square centimeters per second appears in materials science papers on ceramics, metals and rocks, in geophysics tables of rock and soil properties, and in older heat transfer tabulations. Newer publications tend to prefer m²/s or mm²/s, and the same property can appear in all three within a single field. A reader combining data from several decades often has to convert. Because the numbers are used as inputs to heat flow models, a conversion error shows up as a factor of 100 or 10,000, which is easy to spot in the results once you know the expected order of magnitude.
Preserving the conditions of a measurement
Diffusivity changes with temperature, pressure, moisture and crystal or fiber direction. A conversion does not move a value to a different temperature, so a diffusivity quoted at 300 K stays a 300 K figure in any unit. Keep the temperature, the sample state and the method with the number, and carry the stated uncertainty through unchanged apart from the factor. When two sources disagree, compare their conditions before suspecting an error in conversion. A sheet that lists 0.97 cm²/s for aluminum at room temperature and another listing a lower figure at 500 K may both be right for their own conditions.
Cooling of a rock body as a cm²/s problem
Geoscience offers a tidy use of the unit. Crustal rocks have diffusivities near 0.01 cm²/s, about 10^-6 m²/s. A sheet-like body of magma 1 m across loses its heat on a time scale of L² / alpha, which with L = 100 cm is 10,000 / 0.01 = 1,000,000 seconds, or about 12 days. A body 10 m across takes 100 times longer, close to 3 years, and one 100 m across takes about three centuries. These are order-of-magnitude figures that ignore latent heat, fluid flow and the temperature of the surrounding rock, but they show why thin dikes freeze quickly and large intrusions stay hot for geological periods. The same arithmetic with L in meters and alpha in m²/s gives identical times.
Precision and checking
- Keep source diffusivity precision.
- Retain measurement conditions.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Thermal diffusivity converter
- Square centimeters per second to Square meters per second converter (thermal diffusivity)
- Square centimeters per second to Square millimeters per second converter (thermal diffusivity)
- Square centimeters per second to Square feet per hour converter (thermal diffusivity)
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.