Metric lab values meeting US tables
A lab report on a metal sample or a ceramic tile gives diffusivity in cm²/s or mm²/s. A heat-transfer handbook from a US publisher may list the same materials in ft²/h, and a process engineer who works in feet and hours needs the lab figure in those units. This page multiplies the cm²/s value by about 3.87500775002. The result is a thermal diffusivity in ft²/h, and the physical meaning stays the same. Copper at about 1.11 cm²/s becomes 4.3013 ft²/h, which is easy to recognize in an older US table. The page serves that bridge and nothing more, so the material, the temperature and the source stay your responsibility. Keep the original cm²/s value in a neighboring column, because a later reviewer will want to see it.
Why 3.875 comes out of the arithmetic
Start from the definitions. One cm² is 0.0001 m². One ft² is 0.09290304 m², since a foot is exactly 0.3048 m. One hour is 3,600 s. A quantity of 1 cm²/s therefore covers 0.0001 / 0.09290304 = 0.0010764 ft² each second, and in an hour it covers 3,600 times as much, which is 3.875 ft². The page shows the default formula as ft²/h = cm²/s × 3.87500775002. The foot, the hour and the prefixes are all defined, so the factor is a defined ratio and the 12-digit display is its limit. Moving from per second to per hour makes numbers larger, while moving from square centimeters to square feet makes them smaller, and the second effect is the weaker one.
Ten cm²/s as a demonstration
The page opens with 10 cm²/s and returns about 38.75 ft²/h. No ordinary solid has a diffusivity near 10 cm²/s, since copper is near 1.1 and most metals sit well below it. Use real values to check the unit: 0.2 cm²/s gives 0.775 ft²/h, and 1.11 gives 4.3013. Entering the value of a polymer or a wall material, near 0.0014 cm²/s, returns 0.005425 ft²/h, and the small result signals a material in which heat moves slowly. If your answer is larger than the input, the direction is right, because the hourly time scale raises the number more than the square-foot area lowers it. If it is smaller, you probably selected ft²/h as the source by mistake.
Heat-soak time in US units
A common use of diffusivity is a time scale for heat to cross a slab, roughly thickness squared divided by diffusivity. In US units, take a 6 in slab, which is 0.5 ft, with a diffusivity of 0.02 ft²/h. The time is 0.25 / 0.02 = 12.5 hours. Converting the property to the metric side gives about 0.00516 cm²/s, and a 15.24 cm thickness squared is 232.26 cm², so the same time is 232.26 / 0.00516 = about 45,000 seconds, or 12.5 hours. The agreement shows that the conversion preserves the physics. It is a scale estimate only, because real slabs have boundary conditions and layers.
Checking the reverse direction
To verify a conversion, convert it back. Select ft²/h as the source and cm²/s as the target: 5 ft²/h gives 1.29032 cm²/s, and 1 ft²/h gives 0.258064 cm²/s. If you start with 10 cm²/s and the reverse step returns 10, the pair of factors is consistent. A small difference in the last digits comes from rounding in the display and not from an error in the factor. A useful anchor is the pair 1 cm²/s and 3.875 ft²/h, which many people remember after using this page a few times. Keep the unrounded value in a spreadsheet when you chain conversions, and round only for the final report. Two or three significant digits are enough for a material property that has a spread of several percent between sources. When the numbers come from a scanned table, read the time unit twice, because a table in ft²/s would need another factor of 3,600.
Diffusivity moves with temperature
A table entry applies at a stated temperature, and the value for metals usually falls as the temperature rises, while for many insulating solids it changes more slowly. If a US handbook and a lab report give different numbers for the same material, check the temperature, the purity or composition and the direction of heat flow before blaming the conversion. Anisotropic materials such as wood and composites have different values along different axes. The converter changes the unit of one number. It cannot reconcile two sources that measured different things, and it does not interpolate between temperatures.
Not the same as viscosity
Kinematic viscosity shares the dimensions of length squared over time, and a fluid property table might show it in cm²/s as stokes. Do not use a viscosity value here. The two quantities describe different transport processes, heat in one case and momentum in the other, and a conversion of the unit never turns one into the other. Their ratio is the Prandtl number, which for water near room temperature is about 7. If a column header only says cm²/s, look for the word diffusivity or thermal before entering the figure.
Reading a table of common materials
A US handbook may list copper near 4.3 ft²/h, aluminum near 3.8, carbon steel near 0.46, stainless steel near 0.15, concrete near 0.02 and water near 0.0055. Converted to cm²/s, those are about 1.11, 0.98, 0.12, 0.04, 0.005 and 0.0014. The spread across the list is about three orders of magnitude, which is the practical message: metals even out a temperature in seconds, and concrete takes hours. When you transcribe a table, convert one row, compare it with a value you know from a metric source, and then do the remainder. The values are rounded and illustrative, and a specific alloy or mix will differ.
Limits of the conversion
The page does not compute diffusivity from conductivity, density and specific heat, and it does not model transient heat flow. It also does not judge whether a number suits an application. After converting, write the unit with the result, for example 4.3013 ft²/h, so a reader sees both the number and the unit. For design calculations that affect safety or code compliance, use the source document of the property and the method that applies.