Measurement basis
Its stored reference factor is 0.0000258064 m²/s.
Definition conventions
Preserve the thermal meaning when comparing values with the same-looking dimensions.
Conversion method
Multiply ft²/h by the complete recorded factor.
Reference equivalent of ft²/h
1 ft²/h = approximately 0.0000258064 m²/s.
Recorded scale factors: 0.0000258064 for ft²/h; 1 for m²/s.
Worked example
Known input: 10 ft²/h. Reference equivalent: 0.000258064 m²/s. The return conversion gives approximately 10 ft²/h.
The calculation includes squared length and the hour denominator.
Common reference values
| Input (ft²/h) | Reference equivalent (m²/s) |
|---|---|
| 1 | 0.0000258064 |
| 5 | 0.000129032 |
| 10 | 0.000258064 |
| 25 | 0.00064516 |
| 50 | 0.00129032 |
| 100 | 0.00258064 |
Compare one ft²/h with other units
| Target unit | Equivalent of 1 ft²/h | Definition guide |
|---|---|---|
| Square meters per second (m²/s) | 0.0000258064 | Read definition |
| Square millimeters per second (mm²/s) | 25.8064 | Read definition |
| Square centimeters per second (cm²/s) | 0.258064 | Read definition |
The foot-and-hour unit of heat transfer handbooks
Square feet per hour is the thermal diffusivity unit of the US customary system, written ft²/h. It results from the way imperial heat transfer data are laid out, with conductivity in Btu per hour per foot per degree Fahrenheit, density in pounds per cubic foot and specific heat in Btu per pound per degree Fahrenheit. In those units the diffusivity alpha = k / (rho c_p) comes out directly in ft²/h with no conversion step. That is why American mechanical engineering texts and older HVAC and boiler references list diffusivity this way. The unit looks odd to a metric reader, but it keeps the arithmetic of imperial handbooks consistent from start to finish.
The exact factors
The foot is defined as exactly 0.3048 m, so a square foot is exactly 0.09290304 m². Dividing by 3,600 seconds per hour gives exactly 1 ft²/h = 2.58064 x 10^-5 m²/s. In smaller metric units that is 25.8064 mm²/s and 0.258064 cm²/s. The site converters use these factors and run in both directions. The reverse factors are not exact decimals: 1 m²/s is about 38,750.0775 ft²/h, and 1 mm²/s is about 0.03875008 ft²/h. Because the area factor is squared, a common mistake is to use 0.3048 rather than 0.09290304 for the length part. That mistake would give a value about 3.3 times too large.
Typical values in ft²/h
Rounded values show what to expect. Copper is about 4.5 ft²/h, aluminum about 3.8 ft²/h, and carbon steel in the range of roughly 0.4 to 0.5 ft²/h. Stainless steel is about 0.15 ft²/h, concrete and brick fall near 0.02 to 0.04, and water at room temperature is about 0.0056 ft²/h. Air near room temperature is around 0.85 ft²/h. All of these depend on temperature, composition and condition, and they are meant only for scale. The spread from air or copper to water shows why a thick insulation layer or a still liquid heats slowly while a metal bar equalizes quickly.
A worked imperial example
The units cancel neatly in an imperial calculation. Take an illustrative material with k = 10 Btu/(h ft F), density 500 lb/ft³ and specific heat 0.1 Btu/(lb F). Then alpha = 10 / (500 x 0.1) = 0.2 ft²/h. The same value is 5.16128 mm²/s, or 5.16128 x 10^-6 m²/s. A 0.25 ft thick wall of this material responds on a time scale of L² / alpha = 0.0625 / 0.2, about 0.31 hours, or 19 minutes. The numbers are invented for illustration, but the method applies to real tabulated properties, and the consistency check against the metric version is useful when a source mixes systems.
Converting to and from metric diffusivities
To go from ft²/h to m²/s, multiply by 2.58064 x 10^-5. To reach mm²/s, multiply by 25.8064, and to reach cm²/s multiply by 0.258064. A handbook value of 3.76 ft²/h becomes 97.0 mm²/s, which is the figure for aluminum in metric tables. A metric value of 1.1 x 10^-4 m²/s becomes 4.26 ft²/h. The site converters list square feet per hour against square meters, centimeters and millimeters per second in both directions. The time part of the unit is what trips people up, since a factor that handles only the square foot would leave the value per hour instead of per second.
Why the hour appears
The hour reflects how heating and cooling processes were measured in industrial practice. Boiler, kiln, furnace and building loads were quoted per hour, and so were heat flows in Btu/h. Keeping the same time base in diffusivity meant that quantities from different tables could be combined directly. A diffusivity expressed per second is easier for laboratory work, where events last seconds. Mixing the two scales unknowingly leaves an error of 3,600 in a result. If a computed time looks 3,600 times too long or short, check whether a per-hour value was used where a per-second one was assumed, or the reverse.
Relationship to similar-looking quantities
Square feet per hour has the same dimensions as kinematic viscosity expressed in ft²/h and as a diffusion coefficient for mass. The physics differs, and so do the usual sources. Kinematic viscosity of oils is often quoted in centistokes (mm²/s) or in Saybolt seconds, and gas diffusion coefficients usually appear in cm²/s. The ft²/h unit is rare outside thermal work, which helps, but a table titled only with a unit symbol should be checked against its property name. The Prandtl number, kinematic viscosity divided by thermal diffusivity, is dimensionless as long as both are in the same unit, which is a useful test for mixed tables.
Conditions, rounding and what the conversion keeps
The value in a table is tied to a temperature and a material state. Moving it into another unit leaves those details unchanged, and the conversion will not adjust it for a different temperature. Keep the reference temperature, the data source and the number of significant figures with the converted value. Because the factors are exact for the metric units, a rounding mismatch usually comes from the source, not from the conversion. Carry extra digits through multi-step calculations and round only the result, since the squared foot factor makes early rounding more damaging than in a simple length conversion.
Time lag in a masonry wall
Building science gives a practical use of ft²/h. Using an illustrative diffusivity of 0.025 ft²/h for dense concrete or masonry, a wall 1 ft thick has a diffusion time L² / alpha of 1 / 0.025 = 40 hours. A 4 inch brick leaf, 0.333 ft thick, comes to 0.111 / 0.025, about 4.4 hours. The longer time explains why thick masonry smooths out daily temperature swings, delaying and flattening the heat that reaches the inside. The estimate is only a scale, because real walls have layers, air films and moisture, and the actual lag also depends on the surface heat transfer. It shows how the squared thickness drives the result, which matters more than small differences in the diffusivity value itself. Rerunning the 4 inch case with a diffusivity 20 percent higher, 0.03 ft²/h, shortens the time only to 3.7 hours, while doubling the thickness to 8 inches would raise it to about 17.8 hours.
Precision and checking
- Retain source diffusivity precision.
- Keep ft²/h as a complete label.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Thermal diffusivity converter
- Square feet per hour to Square meters per second converter (thermal diffusivity)
- Square feet per hour to Square millimeters per second converter (thermal diffusivity)
- Square feet per hour to Square centimeters per second converter (thermal diffusivity)
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.