MEASUREMENT & METHODS

Thermochemical calories per centimeter second Celsius degree (cal th/(cm·s·°C)): thermal conductivity unit guide

cal th/(cm·s·°C) uses thermochemical energy per length, time and temperature difference.

Measurement basis

The reference factor is 418.4 W/(m·K).

Definition conventions

Temperature denominators are intervals. Conductivity depends on material and conditions.

Conversion method

Multiply by 418.4, preserving the thermochemical calorie and difference-temperature conventions.

Reference equivalent of cal th/(cm·s·°C)

1 cal th/(cm·s·°C) = approximately 418.4 W/(m·K).

Recorded scale factors: 418.4 for cal th/(cm·s·°C); 1 for W/(m·K).

Worked example

Known input: 10 cal th/(cm·s·°C). Reference equivalent: 4184 W/(m·K). The return conversion gives approximately 10 cal th/(cm·s·°C).

The example converts all compound-unit components together.

Common reference values

Input (cal th/(cm·s·°C))Reference equivalent (W/(m·K))
1418.4
52092
104184
2510460
5020920
10041840

Compare one cal th/(cm·s·°C) with other units

Target unitEquivalent of 1 cal th/(cm·s·°C)Definition guide
Watts per meter kelvin (W/(m·K))418.4Read definition
Milliwatts per meter kelvin (mW/(m·K))418400Read definition
Watts per centimeter kelvin (W/(cm·K))4.184Read definition

A conductivity unit from the centimeter-gram-second era

Thermal conductivity says how readily heat flows through a material. The unit cal th/(cm·s·°C) states it as calories per second crossing a one-centimeter cube across a temperature difference of one degree Celsius between opposite faces. Handbooks and journal articles written before the SI took hold used this form constantly, because the centimeter-gram-second system was standard in physics and chemistry. The SI version is W/(m·K). Anyone reading older literature on rocks, metals, glass or soils will meet it. The unit name looks long, but each piece has a job: calories supply the energy, centimeter and second set the geometry and time, and the Celsius degree is a temperature interval that equals a kelvin.

The factor of 418.4

The conversion follows from the definitions of the calorie, the centimeter and the Celsius interval. One thermochemical calorie is 4.184 J. A cal per second is therefore 4.184 W. Dividing by a centimeter, which is 0.01 m, multiplies the number by 100, so 1 cal th/(cm·s·°C) equals 418.4 W/(m·K). The converter uses 418.4 in that direction and 0.00239005736 in the other. In milliwatts, 1 cal th/(cm·s·°C) is 418,400 mW/(m·K), and in W/(cm·K) it is 4.184. Because the calorie is defined exactly, so is this factor. A reported value of 0.0025 in the older unit is 1.046 W/(m·K), the sort of number you expect for window glass.

Where real materials sit

Typical values, approximate and dependent on purity and temperature, give a feel for the magnitude. Copper is about 401 W/(m·K), which is 0.958 cal th/(cm·s·°C). Aluminum is near 237 W/(m·K), or 0.567. Water at room temperature is about 0.6 W/(m·K), or 0.00143. Dry air is roughly 0.026 W/(m·K), which is only 0.0000621 in the older unit, a reminder that the numbers get awkwardly small for insulators. The older literature often shows exponents such as 6 × 10⁻⁵ for that reason. For rocks, 2 to 3 W/(m·K) is a common range, equal to 0.0048 to 0.0072. A spread of four orders of magnitude between copper and air is what makes insulation worthwhile.

Why the exponents run negative

The calorie is a small energy and the centimeter is a small length, so for most everyday materials the numerical value in this unit comes out below one, and for good insulators far below. A foam board with a conductivity of 0.03 W/(m·K) becomes 0.0000717 in cal th/(cm·s·°C). Texts therefore write such values in scientific notation, like 7.2 × 10⁻⁵, and an easy mistake is to drop or shift an exponent while converting. A useful check is the direction: going from SI to this unit shrinks the number by 418.4, going the other way grows it. If a foam appears more conductive than copper after a conversion, a factor was inverted. Writing both versions side by side catches slips.

A worked heat-flow example

Conduction through a slab follows Q = k × A × ΔT / L. For glass with k of 0.0025 cal th/(cm·s·°C), take a pane of 100 cm by 100 cm, 0.4 cm thick, with a 20 °C difference across it. The heat rate is 0.0025 × 10,000 × 20 / 0.4 = 1,250 cal/s, which is 5,230 W. That large figure for such a pane is a conduction-only estimate with fixed surface temperatures. Real windows have boundary air layers that cut the flow drastically, so actual losses are much smaller. The example shows how the unit combines with centimeters and seconds, and why a mixed set of units, such as centimeters in the slab and meters in a room, needs conversion before multiplication.

Interval degrees, not readings

The Celsius degree in the denominator is a temperature difference. One degree Celsius of interval equals one kelvin, so there is no scale offset between cal th/(cm·s·°C) and a unit written with K in the denominator. A 20 °C difference across a slab equals 20 K. Converting a Celsius reading such as 25 °C to 298.15 K does not belong in this unit conversion. The same logic applies to Fahrenheit-based conductivities, where the interval is 5/9 of a kelvin. Keep conductivity separate from thermal resistance and heat capacity, which use different combinations of the same base quantities. The conductivity converter family on this site is labeled to keep those quantities from being mixed in one table.

Conductivity depends on the material state

A tabulated conductivity is a property of a particular sample under stated conditions. Temperature, moisture, density, grain direction, purity and pressure all change it. Wet soil conducts better than dry soil, compressed insulation conducts better than fluffed insulation, and many metals drop in conductivity as alloying elements are added. The unit conversion keeps the number the same physical size, so it cannot make a value more reliable. A figure copied from an older table inherits that table's method and its reference conditions. When two sources disagree by a few percent after conversion, differences in samples or measurement are more likely culprits than the factor 418.4, which is an exact definition.

Related units and where to look next

Other conductivity units in common use include W/(cm·K), where 1 W/(cm·K) is 100 W/(m·K), and mW/(m·K), used for insulation, where 1 W/(m·K) is 1,000 mW/(m·K). Imperial work uses BTU·in/(h·ft²·°F), a different grouping that incorporates thickness. The R-value of a building product is a separate quantity, a thermal resistance per area, and equals thickness divided by conductivity. Converting between those needs more information than a single factor. For a quick scale check, remember that 1 cal th/(cm·s·°C) is a very conductive material by everyday standards, slightly above the conductivity of copper, and typical building materials are in the range of 10⁻⁴ to 10⁻².

Soil and rock in the older literature

Geophysics and soil science kept the calorie-based unit longer than most fields, and many heat-flow tables in geology still list conductivity in units of 10⁻³ cal per centimeter second degree. Terrestrial heat flow is the classic case: the average continental value is about 65 mW/m², and the older shorthand 1 heat-flow unit, abbreviated HFU, equals 10⁻⁶ cal th/(cm²·s), which is 41.84 mW/m². A reading of 1.5 HFU is therefore 62.8 mW/m². Conductivity enters through the geothermal gradient: flux equals conductivity times gradient, so rock at 2.5 W/(m·K) with a 25 K/km gradient carries 62.5 mW/m². Converting both units before combining them avoids mixing a calorie factor with a kilometer factor.

Precision and checking

  • Retain source conductivity precision.
  • Keep th and the full denominator.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →