Insulation data sheets use milliwatts, metal tables use watts

Foam boards, aerogel blankets and vacuum panels are often rated in mW/(m·K), because their values sit in the tens. A product listed at 18 mW/(m·K) has a conductivity of 0.018 W/(m·K). Mineral wool and wood fiber boards are more often listed as 0.035 to 0.040 W/(m·K), and metals are quoted in the hundreds of W/(m·K). A builder comparing an aerogel quote with a wool batt, or a student reading a handbook next to a manufacturer sheet, has to restate one figure in the other unit before the comparison means anything. This page multiplies or divides by 1,000 for that case, and it also handles centimeter-based and calorie-based units that older tables still print.

Four units, one base

The page stores W/(m·K) as the base. Milliwatts per meter kelvin is 0.001 of it, and watts per centimeter kelvin is 100 times larger, because a centimeter is a hundredth of a meter and the length sits in the denominator. The thermochemical calorie is 4.184 J, so one cal/(cm·s·°C) equals 418.4 W/(m·K). The formula shown for the default is mW/(m·K) = W/(m·K) × 1000. Conductivity uses a temperature difference, so kelvin and degree Celsius are the same size here, and no offset is applied. NIST SP 811 gives the calorie and the SI prefixes behind these factors, and the converter applies them to the supplied number in one step.

Ten watts per meter kelvin on the page

The default of 10 W/(m·K) returns 10,000 mW/(m·K). The value is a demonstration. Stainless steel is usually listed at roughly 15 W/(m·K), glass near 1, water near 0.6 and still air near 0.026 at room temperature, so 10 sits in the range of poor metals and some ceramics. Setting the page to a real material is a better test of the unit choice. Entering 0.026 with W/(m·K) as the source gives 26 mW/(m·K) in the target, a figure that matches how air is usually described in insulation work. If the result looks wrong by a factor of 1,000, check that the source and target were not swapped.

Comparing an aerogel quote with a wool batt

Take an aerogel blanket listed at 18 mW/(m·K) and mineral wool at 0.035 W/(m·K). In one unit the blanket is 0.018 W/(m·K) and the wool is 35 mW/(m·K), so the blanket conducts about half as much heat for the same thickness. For a one square meter wall layer 0.1 m thick with a 20 K difference across it, heat flow is conductivity times area times temperature difference divided by thickness. With wool that is 0.035 × 1 × 20 / 0.1, or 7 W. With the aerogel it is 3.6 W. These are illustrative numbers. Real assemblies include air films, framing and moisture, so the page gives a material figure and not a wall rating.

Thermal paste and heat spreaders

Thermal interface pastes are advertised in W/(m·K), and claims of 4 to 12 are common. A paste marketed at 8 W/(m·K) is 0.08 W/(cm·K) in a table that uses centimeters, and 8,000 mW/(m·K) in one that uses milliwatts. Copper is about 385 to 400 W/(m·K), which is 3.85 to 4.0 W/(cm·K), so the metal still conducts far better than the paste. What limits cooling in practice is the thin layer of paste and the contact surfaces. A bulk conductivity figure does not capture contact resistance, and independent measurements of pastes often differ from the label. The page converts the unit and does not predict a temperature at a processor.

Calorie units in older handbooks

Handbooks from the CGS era list conductivity in cal/(cm·s·°C), and the values look small: copper appears near 0.94 and water near 0.0014. With the factor of 418.4, 0.94 becomes about 393 W/(m·K), and 1 cal/(cm·s·°C) is exactly 418.4 W/(m·K) when the thermochemical calorie is used. Some tables use the international table calorie, which differs slightly at the fourth digit, so confirm which calorie a source means. The page applies the thermochemical definition. For an engineering estimate the difference is negligible, but for a published comparison of tabulated values it can explain a small gap between two sources.

Conductivity varies with temperature and moisture

A single figure on a data sheet belongs to one temperature, often 10 or 23 degrees Celsius, and one moisture state. Insulation that becomes damp conducts more heat, and metals and gases change with temperature. Foam can also age as gas leaves its cells, so a declared value and an in-service value may differ. The converter changes the unit of the number you give it, and it does not adjust that number for conditions. If a design needs a value at a particular temperature, take it from a measurement or table at that temperature and convert afterward. Note the temperature and test method beside each value in your records.

Heat sinks and aluminum versus copper

Heat sink makers list aluminum alloys with conductivities between roughly 150 and 235 W/(m·K), and copper near 390. In W/(cm·K) those are about 1.5 to 2.35 and 3.9. A designer comparing a copper base plate with an aluminum one needs the numbers in one unit before asking how much temperature rise the swap would remove. A plate 5 mm thick has a conduction resistance per square meter of thickness divided by conductivity, which is 0.005 / 390, about 1.3 × 10^-5 m²·K/W for copper, and 0.005 / 200, 2.5 × 10^-5 for aluminum. Those are small against a paste layer or an air gap, which is why spreading, not bulk conduction, usually decides the outcome.

Conductivity, not resistance

Conductivity is a property of a material, and a higher number means more heat flow. R-value and thermal resistance describe a layer of a given thickness, and a higher number means less heat flow. Do not feed an R-value into this page expecting a conductivity. To go from conductivity to resistance of a layer, divide the thickness in meters by the conductivity in W/(m·K), so 0.1 m of 0.035 W/(m·K) wool gives about 2.86 m²·K/W. This page stops at the unit change, and it does not check code requirements or certify a product for any use.