What thermal conductivity describes

Thermal conductivity is a property of a material that says how readily heat flows through it by conduction. Fourier's law gives the heat flow per unit area as q = −k × dT/dx, where k is the conductivity and dT/dx is the temperature gradient. For a flat layer of thickness L with a temperature difference ΔT across it, the heat flux is q = k × ΔT / L. The SI unit is watt per meter kelvin, W/(m·K), which in base units is kg·m·s⁻³·K⁻¹. A material with k = 0.04 W/(m·K) passing heat through a 0.1 m layer with a 20 K difference carries 0.04 × 20 / 0.1 = 8 watts through each square meter. The kelvin in the denominator is a temperature interval, so a difference of 20 K is also a difference of 20 °C.

Typical values across materials

Conductivities span about five orders of magnitude, and a few anchor values help to judge a number. Silver is near 429 W/(m·K) and copper near 400. Aluminum is around 237 for the pure metal, while carbon steels sit around 45 to 55 and stainless steels around 15. Window glass is roughly 1 W/(m·K), and concrete is in the range of about 1 to 2. Liquid water is near 0.6 at room temperature. Dry wood across the grain is about 0.1 to 0.2, and still air at room temperature is about 0.026. Insulating foams and wools run from about 0.02 to 0.045. Aerogel blankets reach 0.015 or so, and vacuum insulation panels are lower still, around 0.004 to 0.008. These values are approximate and depend on temperature, density and moisture, so a datasheet or a published table with its conditions is the source for any design number.

Units in common use and how they relate

Thermal conductivity appears in SI form and in US customary form. The SI forms are W/(m·K) and the milliwatt version, mW/(m·K), which differ by a factor of 1,000. The US customary forms are BTU per hour per foot per degree Fahrenheit, BTU/(h·ft·°F), and the form common in insulation, BTU·in/(h·ft²·°F), which has the thickness in inches. Using the International Table BTU, 1 BTU/(h·ft·°F) is 1.730735 W/(m·K), and 1 BTU·in/(h·ft²·°F) is 1.730735 / 12 = 0.1442279 W/(m·K). The reverse is that 1 W/(m·K) equals about 6.9335 BTU·in/(h·ft²·°F). Each compound unit carries a power term, a length term and a temperature-interval term, and a correct conversion applies a factor to each one. The Fahrenheit degree in the denominator is an interval of 5/9 K, not a point on a temperature scale, so no offset is added.

Worked conversion into US units

Take mineral wool with a conductivity of 0.038 W/(m·K). In BTU·in/(h·ft²·°F) the value is 0.038 × 6.9335, about 0.2635. The thermal resistance of one inch of that material, in US units, is the reciprocal, 1 / 0.2635 = 3.80, so the R-value per inch is about 3.8 °F·ft²·h/BTU. A product with k of 0.040 W/(m·K) gives 0.040 × 6.9335 = 0.2773 and R of 3.61 per inch. In SI terms, a layer of thickness 0.1 m and k of 0.04 has a resistance L/k = 2.5 m²·K/W, or RSI 2.5. To convert RSI to US R-value, multiply by 5.678263, which gives 14.2 for this layer. The numbers are illustrative values for generic insulation and are not product specifications. Keep the full unit when you copy such figures, since a bare 0.26 could be either system.

Conductivity is not the whole assembly

A material's conductivity does not determine the thermal behavior of a wall, roof or window. The assembly resistance adds the resistances of every layer, L/k for each, plus surface film resistances on the inside and outside. Thermal bridges, such as studs, fasteners and metal frames, carry heat around the insulation, and air movement can bypass it. The U-value of the assembly is the reciprocal of the total resistance, in W/(m²·K), and building regulations and energy codes set limits on it. A layer of foam with k of 0.03 W/(m·K) and a thickness of 0.15 m has a resistance of 5 m²·K/W, but if the wall behind it has a steel stud grid that bridges the layer, the effective result can be much lower. Conductivity feeds these calculations as an input and cannot replace them. A unit conversion changes only the scale of the material property.

How conductivity is measured

Standard test methods exist for measuring conductivity of solids and insulation. The guarded hot plate method, described in ASTM C177 and ISO 8302, places a specimen between a heated and a cooled plate, with a guard ring that limits edge losses, and computes k from the steady-state heat flow and temperature difference. The heat flow meter method, in ASTM C518 and ISO 8301, uses a calibrated heat flux transducer and is faster for routine testing. Transient techniques, such as the hot-wire and hot-disk methods, heat a probe and record the temperature rise over time, and they suit fluids, powders and small samples. The laser flash method measures thermal diffusivity, which combines with density and specific heat to give conductivity through k = α × ρ × cp. Because each method has its own uncertainty, a stated conductivity should come with the method, the mean test temperature and the specimen condition.

Temperature, moisture and aging

Conductivity changes with conditions. Insulation values are normally quoted at a mean temperature of 10 °C or 24 °C, depending on the standard, and rise as the mean temperature increases, since gas conduction and radiation inside the pores both grow with temperature. Moisture raises conductivity sharply, because water conducts heat about twenty times better than still air. A wet insulation layer performs worse than its dry rating, and the loss is not recovered unless it dries. Some closed-cell foams contain blowing agents that slowly diffuse out and are replaced by air, raising the conductivity over the first years. Standards address this with aged or design values. In the European system, a declared value λD is given for a stated fractile of production and aging allowance. Comparing values at different temperatures or after different aging gives a misleading ranking, so match the conditions first.

Material properties that look similar

Several related quantities are easy to confuse with conductivity. Thermal diffusivity, in m²/s, describes how fast a temperature change spreads and equals k divided by density times specific heat. Thermal resistance in m²·K/W depends on thickness, and thermal conductance, also called the C-factor, is the reciprocal of resistance for a given piece of material, in W/(m²·K). Thermal effusivity describes how a surface feels to the touch, and explains why a metal handle feels colder than wood at the same temperature. Heat transfer coefficient h describes convection or the combined film at a surface. Conductivity is also not the same as electrical conductivity, though in metals the two are linked by the Wiedemann-Franz law. Each of these has a different unit, so the right conversion starts by identifying the quantity before choosing a factor.

Notation across regions

Different fields use different symbols. In physics and North American engineering the symbol is k. In European building standards the symbol is λ (lambda), and a product declares a value like λ = 0.032 W/(m·K). Some older texts use κ. The unit is written W/(m·K) with the parentheses, because W/m·K could be read as watts per meter, multiplied by kelvin. The parentheses are the clear form recommended in SI practice. The dot between m and K is a multiplication sign, and some documents use a space or write W·m⁻¹·K⁻¹ instead. In the US the unit is spelled BTU·in/(h·ft²·°F) in insulation literature, and some tables use the shortened form of k as BTU·in/hr·ft²·°F. When reading a table, read all terms in the denominator, because dropping the inch or the foot changes the value by a factor of 12.

Choosing the right unit for the job

The best unit depends on the audience and the material. For metals and structural materials, W/(m·K) gives numbers from about 1 to 400 that are easy to read. For insulation and gases, values in W/(m·K) are small decimals, so the milliwatt form puts them in whole numbers, such as 32 mW/(m·K) instead of 0.032 W/(m·K). Manufacturers of insulating glass gas fills, vacuum panels and aerogels often use that form. US building practice uses BTU·in/(h·ft²·°F) so that the R-value of a layer is its thickness in inches divided by k. A conversion should be made once, at the start of a calculation, and the result kept in the form used by the downstream formula. Carry enough digits in intermediate steps, since the factor 6.9335 turns a three-digit conductivity into a figure whose last digit is not reliable if the original was rounded.

What a unit rewrite cannot establish

Changing the unit of a conductivity does not make two values comparable. They must refer to the same material state, temperature, direction and moisture content. Anisotropic materials, such as wood, graphite sheets, composites and many laminates, have different conductivities along and across their structure, and a single number applies to one direction only. A unit rewrite does not predict condensation, fire behavior, mechanical strength or the long-term durability of an insulation product. It does not size a heating system, either, because that needs the whole building envelope, air leakage and ventilation. The conversion keeps the material quantity intact and lets the number be used in a formula or a table that expects a different unit.

Precision and checking

  • Retain measured conductivity precision and conditions.
  • Keep the length and temperature terms in the denominator.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Choose a unit definition

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.