Measurement basis
The unit retains power per length and temperature difference.
Definition conventions
Temperature denominators are intervals. Conductivity depends on material and conditions.
Conversion method
Keep W/(m·K) unchanged; use another conductivity factor for the target.
Reference equivalent of W/(m·K)
1 W/(m·K) = approximately 1 W/(m·K).
Recorded scale factors: 1 for W/(m·K); 1 for W/(m·K).
Worked example
Known input: 10 W/(m·K). Reference equivalent: 10 W/(m·K). The return conversion gives approximately 10 W/(m·K).
The calculation preserves thermal conductivity.
Common reference values
| Input (W/(m·K)) | Reference equivalent (W/(m·K)) |
|---|---|
| 1 | 1 |
| 5 | 5 |
| 10 | 10 |
| 25 | 25 |
| 50 | 50 |
| 100 | 100 |
Compare one W/(m·K) with other units
| Target unit | Equivalent of 1 W/(m·K) | Definition guide |
|---|---|---|
| Milliwatts per meter kelvin (mW/(m·K)) | 1000 | Read definition |
| Watts per centimeter kelvin (W/(cm·K)) | 0.01 | Read definition |
| Thermochemical calories per centimeter second Celsius degree (cal th/(cm·s·°C)) | 0.00239005736138 | Read definition |
The coherent SI unit for how well a material conducts heat
Watts per meter kelvin is the SI unit of thermal conductivity, usually written k or lambda. A material with k = 1 W/(m·K) passes 1 W through a slab 1 m thick and 1 m² in area when the two faces differ by 1 K. In base units it is kg·m·s⁻³·K⁻¹. The kelvin is defined in the 2019 SI by fixing the Boltzmann constant at exactly 1.380649 × 10⁻²³ J/K, and a temperature difference of 1 K equals a difference of 1 °C. The Fourier law in one dimension states that heat flux equals k times the temperature gradient. Standards for building materials, heat exchangers and electronics sheets give conductivity in this unit.
Air, water, glass, steel, copper
Approximate values at around room temperature show how wide the range is, and they vary with composition, temperature and test method. Still air is about 0.026 W/(m·K), polyurethane and polystyrene foams about 0.02 to 0.04, mineral wool about 0.03 to 0.045, and water about 0.6. Window glass sits near 1, concrete between about 1 and 2, stainless steel around 15, aluminum near 237 for pure metal and copper close to 400. Diamond reaches roughly 2,000. Insulation datasheets typically quote the declared value measured by a standard such as a guarded hot plate method. Gases and good insulators are often given in mW/(m·K), where air is about 26.
Scaling to smaller units and the centimeter version
Prefix changes are plain powers of ten. One W/(m·K) is 1,000 mW/(m·K), so air at 0.026 W/(m·K) appears as 26 mW/(m·K). The site converters Watts per meter kelvin to Milliwatts per meter kelvin and Milliwatts per meter kelvin to Watts per meter kelvin handle this. The length in the denominator also changes the number when you switch to centimeters: 1 W/(m·K) is 0.01 W/(cm·K), and the converter Watts per meter kelvin to Watts per centimeter kelvin applies that factor. The calorie version uses the thermochemical calorie, 4.184 J exactly: 1 W/(m·K) is about 0.00239006 cal th/(cm·s·°C), and the converter Thermochemical calories per centimeter second Celsius degree to Watts per meter kelvin multiplies by 418.4.
From conductivity to R-value in a wall layer
Thermal resistance per unit area of a homogeneous layer is thickness divided by conductivity. For 100 mm (0.1 m) of mineral wool with k = 0.04 W/(m·K), R = 0.1 / 0.04 = 2.5 m²·K/W, and the corresponding transmittance of that layer alone is 0.4 W/(m²·K). Heat flow through 20 m² with a 15 K difference is 0.4 × 20 × 15 = 120 W. In US practice the same resistance is quoted in ft²·°F·h/Btu, and 1 m²·K/W equals about 5.678 of those, so 2.5 m²·K/W is roughly R-14.2. A whole wall needs the resistances of every layer, surface films and the effect of framing, which a single conductivity conversion cannot provide.
Temperature, moisture and density change the value
A conductivity is valid only for stated conditions. Metals typically change slowly near room temperature, while many insulation materials rise as temperature climbs. Moisture raises the effective conductivity of porous materials, which is why wet insulation performs worse than dry insulation, because water conducts more than 20 times better than air. Density has a large effect on foams and fibrous products. Anisotropic materials such as wood, graphite sheets and fiber composites have different values along different directions, and a single number can describe only one of them. Pure and alloyed forms of a metal differ greatly: pure aluminum is near 237 W/(m·K), while many cast aluminum alloys are far lower. Quote the temperature and the material form with the figure.
Inch-pound conductivity and why tables disagree
American tables often list conductivity in Btu·in/(h·ft²·°F). With the International Table Btu, one such unit equals approximately 0.1442 W/(m·K), so a fiberglass value of 0.25 in those units is about 0.036 W/(m·K). The exact value depends on whether the Btu is the International Table or the thermochemical version, which differ by a small fraction of a percent, and tables that disagree in the fourth digit often differ only in this choice. A published figure should name its Btu definition when precision matters. The site does not provide a converter for this inch-pound unit, so a calculation from such a table needs a reliable factor from NIST SP 811 or the table source.
Material property versus assembly result
A conductivity conversion describes a material and does not establish how a complete assembly performs. The thickness, area, joints, fasteners, air gaps, surface films and the actual temperatures decide the heat flow. Thermal bridges through studs or metal ties can cut the effective resistance of a wall well below what the insulation layer alone suggests. Heat flow through the same material also depends on whether the temperatures are steady, since a changing environment engages thermal mass and time lag, not conductivity alone. Use the converted conductivity as an input to a layered resistance calculation, and state the temperature and test standard from the source datasheet.
Checking declared values against the converters
Insulation datasheets often publish a declared value such as 0.036 W/(m·K) for expanded polystyrene. That is 36 mW/(m·K), or 0.00036 W/(cm·K). An aerogel blanket listed at about 0.015 W/(m·K) is 15 mW/(m·K), lower than still air at 26 mW/(m·K) because the pore structure restricts gas motion. If you convert in the other direction, a reading of 150 mW/(m·K) is 0.15 W/(m·K), typical of dry wood across the grain. Doing a round trip through the site converters should return the starting value, and a mismatch means a unit was selected wrongly. Write the unit with its prefix in the table, since 0.036 and 36 look unrelated without it.
Conductivity, diffusivity and conductance are different quantities
Conductivity k in W/(m·K) says how much heat passes under a gradient. Thermal diffusivity, alpha = k / (density × specific heat), has units of m²/s and says how fast a temperature change spreads. For copper with k = 400 W/(m·K), density 8,960 kg/m³ and specific heat 385 J/(kg·K), alpha = 400 / (8,960 × 385), about 1.16 × 10⁻⁴ m²/s. Conductance of an object, k × area / thickness, has units W/K. The U-value of an assembly has units W/(m²·K). Each of these has its own unit, and mixing them up is a common source of errors when comparing sheets from different suppliers.
Precision and checking
- Keep source conductivity precision.
- Retain material and temperature conditions.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Thermal conductivity converter
- Watts per meter kelvin to Milliwatts per meter kelvin converter
- Watts per meter kelvin to Watts per centimeter kelvin converter
- Watts per meter kelvin to Thermochemical calories per centimeter second Celsius degree converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.