Where W/(cm·K) is still used
Watts per centimeter kelvin survives in physics and electronics because the geometry of a chip or a crystal is naturally in centimeters. Semiconductor handbooks list the thermal conductivity of silicon, germanium, gallium arsenide and silicon carbide in W/(cm·K), and heat sink and package analyses often keep that system. Silicon is about 1.5 W/(cm·K) near room temperature, copper about 4, and high-quality diamond in the range of 20. Older versions of the same tables gave values in cal/(cm·s·°C). This page connects the two, so a data series from a classic source can be matched to a modern device model without a trip through W/(m·K) first. The same unit shows up in thermal-interface material specifications, heat spreaders and laser crystal data, where a layer is often a fraction of a millimeter thick and a centimeter is the natural length for the area.
The factor of 4.184 and why it is so simple
Both units keep the centimeter, so the length factor cancels. Only the calorie to joule step remains, and a thermochemical calorie is exactly 4.184 J according to NIST SP 811. One second of time is the same in both units, and a Celsius degree interval equals a kelvin. The conversion is therefore multiplication by 4.184. This is the simplest of the conductivity converters on the site and is exact for round inputs. The default of 10 gives 41.84 W/(cm·K). For comparison, converting to W/(m·K) multiplies the result by another 100, which gives 4,184.
Realistic values for semiconductors and metals
An old table might list silicon at 0.36 cal th/(cm·s·°C). Multiplying by 4.184 gives 1.506 W/(cm·K), which matches the roughly 1.5 quoted for silicon at 300 K. Copper at 0.96 gives 4.017 W/(cm·K). Glass at 0.0024 gives 0.01004 W/(cm·K). Aluminum at 0.5 gives 2.092. Gallium arsenide, with a conductivity near 0.55 W/(cm·K), would be about 0.13 cal th/(cm·s·°C) in the older system, which explains why GaAs devices need more careful heat spreading than silicon ones. These values show how widely conductivity ranges, and why a page with a default of 10 sits far beyond any practical material. When you are checking a result for sense, anything above about 20 W/(cm·K) would exceed even diamond at room temperature.
Using the result in a chip heat calculation
For a layer of thickness t and area A, the thermal resistance is t divided by k times A, with k in W/(cm·K), t in centimeters and A in square centimeters. A silicon die 0.05 cm thick with an area of 1 cm² and k of 1.5 W/(cm·K) has a resistance of 0.05 divided by 1.5, which is about 0.033 K/W through its thickness. A 100 W heat load then produces about 3.3 K across the die. The unit choice makes this arithmetic simple because the dimensions stay in centimeters, and the converted value drops directly into that formula. If the die were copper instead, with 4.017 W/(cm·K), the same geometry would give 0.0124 K/W, about a third of the silicon figure, and the temperature drop for 100 W would be about 1.2 K. Comparing the two cases shows what a conductivity ratio of about 2.7 does to a stack.
Converting back to the calorie system
Choose Watts per centimeter kelvin in the From menu and the calorie unit in the To menu to divide by 4.184. A value of 1.5 W/(cm·K) converts to 0.3585 cal th/(cm·s·°C), and 4.01 W/(cm·K) converts to 0.9584. A reverse conversion is useful for comparing a modern measured value for a crystal with a historic one in a paper, where the older number was written in calories. The two should agree within the stated uncertainty if the sample and temperature match, and a mismatch of a few percent often reflects different purity or temperature rather than a unit error. Differences of 5 to 10 percent between two published values for the same crystal are common, and a 0.07 percent shift from using a different calorie definition would be invisible among them.
Temperature dependence you should not ignore
Conductivity of crystalline solids changes with temperature. Silicon falls from about 1.5 W/(cm·K) at 300 K to about 1.0 at 400 K, and rises sharply at low temperature before declining again near very low temperatures. A single converted number applies only at the temperature of the source measurement. The converter changes units and does not adjust for this, so make sure the temperature of the original value is the one relevant to your device. Operating temperature in a power device is often 350 to 400 K, so a value taken at 300 K overstates conductivity by a noticeable margin.
Common pitfalls with this unit
The calorie in the unit is the small calorie, not the food Calorie. Entering a figure in kilocalories per centimeter second degree, which is unusual but appears in some old reports, would make the output 1,000 times too small. The unit also differs from W/(cm²·K), which describes heat transfer coefficients and has a different dimension. A conductivity has length in the denominator once, and a heat transfer coefficient has none, so the two should never be interchanged. Readers sometimes meet W/(cm·K) written as W/cm/K or W cm-1 K-1. All three mean the same unit, and the converter treats them identically.
Digits for crystal conductivity values
Because the multiplier is exact, converted values carry the precision of the input. Published conductivities for pure crystals are quoted to two or three digits, so round results to three significant digits.