Measurement basis
One P corresponds to 0.1 Pa·s.
Definition conventions
A direct unit comparison remains within dynamic viscosity and does not supply density for a kinematic relationship.
Conversion method
Multiply P by 0.1 for the reference viscosity.
Reference equivalent of P
1 P = approximately 0.1 Pa·s.
Recorded scale factors: 0.1 for P; 1 for Pa·s.
Worked example
Known input: 10 P. Reference equivalent: 1 Pa·s. The return conversion gives approximately 10 P.
The reference retains dynamic viscosity.
Common reference values
| Input (P) | Reference equivalent (Pa·s) |
|---|---|
| 1 | 0.1 |
| 5 | 0.5 |
| 10 | 1 |
| 25 | 2.5 |
| 50 | 5 |
| 100 | 10 |
Compare one P with other units
| Target unit | Equivalent of 1 P | Definition guide |
|---|---|---|
| Pascal seconds (Pa·s) | 0.1 | Read definition |
| Millipascal seconds (mPa·s) | 100 | Read definition |
| Micropascal seconds (µPa·s) | 100000 | Read definition |
A CGS unit named after a physician
The poise, symbol P, is the CGS unit of dynamic viscosity, defined as one gram per centimeter per second, g·cm⁻¹·s⁻¹. It equals exactly 0.1 Pa·s. The name honors Jean Léonard Marie Poiseuille, a French physician and physicist who studied the flow of liquids through narrow tubes in the 1830s and 1840s, in the context of blood circulation. The Hagen-Poiseuille law, which gives flow rate through a tube from pressure, radius, length and viscosity, carries his name. The poise is not an SI unit, but it persists in laboratories, in the coatings and petroleum trades, and in older literature. The chosen size also explains its history, since a poise is a large unit for ordinary liquids, and the hundredth of it matches water. Its hundredth, the centipoise, is far more common than the poise itself.
Centipoise and the water anchor
One centipoise, cP, is 0.01 P, which equals 1 mPa·s. The size was set by convenience, since water at 20 °C has a viscosity of about 1.002 cP, which is very close to 1 cP. Water at 25 °C is about 0.890 cP. This anchor lets a reader judge a figure quickly, and a fluid at 100 cP is about 100 times as viscous as water. Glycerol at 20 °C is about 1,412 cP, and mercury is about 1.53 cP, which is thicker than water despite its mobility. Air at 20 °C is about 0.0181 cP, or 1.81 × 10⁻⁴ P. Temperature dependence is steep, so every viscosity figure needs its temperature next to it. Water falls from 1.79 cP at 0 °C to about 0.28 cP at 100 °C, and many oils lose more than 90 percent of their viscosity between room temperature and 100 °C.
Poise to pascal seconds on this site
The Computandum dynamic viscosity converters give the following factors. Poise to Pascal seconds multiplies by 0.1, and Pascal seconds to Poise multiplies by 10. Poise to Centipoise multiplies by 100, and Centipoise to Poise by 0.01. Poise to Millipascal seconds multiplies by 100, and Poise to Micropascal seconds by 100,000. A viscosity of 12 P is therefore 1.2 Pa·s, 1,200 cP and 1,200 mPa·s. A thin oil of 0.5 P is 0.05 Pa·s and 50 cP. Because the poise is exactly one tenth of the pascal second, none of these conversions introduces rounding, and any difference between two tables comes from how the digits were truncated.
Poise and stokes are different quantities
The stokes, St, is the CGS unit of kinematic viscosity, one square centimeter per second, named after the mathematician George Gabriel Stokes. Kinematic viscosity equals dynamic viscosity divided by density, so a poise value cannot be turned into a stokes value without the density of the fluid. A fluid of 100 cP and a density of 0.87 g/cm³ has a kinematic viscosity of 100/0.87, which is 114.9 cSt. The same dynamic viscosity at a density of 1.26 g/cm³ gives 79.4 cSt. The names look alike and the units both come from CGS, which is why they are confused. Using the density of water at 20 °C, 0.9982 g/cm³, 1.002 cP corresponds to 1.004 cSt, which is why water is said to have a viscosity of about one in either system. One stokes equals 10⁻⁴ m²/s, and one centistokes equals 1 mm²/s.
Poiseuille is a different unit
The French physicist also gives his name to the poiseuille, symbol Pl, a unit that equals one pascal second. It was used in France and appears in some texts, but it is not an SI name and has largely disappeared. One poiseuille equals 10 poise. A reader who sees Pl in an old table should multiply by 10 to reach poise, or use the number directly as pascal seconds. A value of 0.02 Pl is 0.02 Pa·s, 0.2 P or 20 cP. The risk is a factor of ten error, because the names are nearly the same. The poise is the unit with the symbol P, and the poiseuille has the symbol Pl. In modern work, Pa·s and mPa·s have replaced both, and recommendations from standards bodies favor the SI form.
Instruments and industries that still report in poise
Rotational viscometers made for paints, inks, adhesives and food products often display centipoise by default. Brookfield-type instruments give readings in cP or mPa·s at a stated spindle and speed. Honey, syrup, cosmetic creams and drilling muds are commonly described in thousands of cP, and a figure of 10,000 cP equals 100 P or 10 Pa·s. Capillary instruments and ASTM or ISO methods for oils report kinematic viscosity in cSt or mm²/s, so a conversion step with density is needed to compare. Comparing a reading with a competitor datasheet requires the same temperature, shear rate and spindle, since for non-Newtonian fluids the number changes with each.
Reading viscosity charts and tables
Charts for lubricants, resins and foods often list a few reference points. Mercury, water and glycerol give a handy ladder at 20 °C, from 1.53 cP through 1.00 cP to 1,412 cP. Each factor of ten on a logarithmic axis marks a visible step. A thin lubricant at 0.2 P is 20 cP and a heavy gear oil at 5 P is 500 cP. Corn syrup, honey and molasses may range from several hundred to several thousand cP depending on water content. Moving from poise to pascal seconds requires only a decimal shift, but the label must be read carefully. A table headed viscosity in P and containing values like 14.1 may mean glycerol at 14.1 P, which is 1.41 Pa·s, and the same row could be misread as 14.1 cP if the heading is lost in copying.
Notation and sources of confusion
The symbol for poise is a capital P, and it should not be mixed up with Pa, the pascal, or with p for pressure. A lowercase p with a unit denotes pico. The centipoise has the symbol cP, and cp in lowercase appears in informal text. The Greek letters eta and mu both stand for dynamic viscosity in formulas, and nu for kinematic viscosity. Metric countries that use SI have replaced the poise in official documents, but the unit remains in supplier datasheets, and NIST SP 811 treats the poise as a CGS unit outside the SI. A quoted value should keep the original unit and add the SI equivalent, so that either convention can be checked against the other.
Precision and checking
- Keep measured viscosity precision.
- Retain the poise convention.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Dynamic viscosity converter
- Poise to Pascal seconds converter
- Poise to Centipoise converter
- Poise to Millipascal seconds converter
- Poise to Micropascal seconds converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.