MEASUREMENT & METHODS

Pascal seconds (Pa·s): dynamic viscosity unit guide

Pa·s is the reference unit for dynamic viscosity.

Measurement basis

The product of pressure and time retains this viscosity quantity.

Definition conventions

A direct unit comparison remains within dynamic viscosity and does not supply density for a kinematic relationship.

Conversion method

Keep Pa·s unchanged; divide by a target dynamic-viscosity factor for another unit.

Reference equivalent of Pa·s

1 Pa·s = approximately 1 Pa·s.

Recorded scale factors: 1 for Pa·s; 1 for Pa·s.

Worked example

Known input: 10 Pa·s. Reference equivalent: 10 Pa·s. The return conversion gives approximately 10 Pa·s.

The example preserves dynamic viscosity.

Common reference values

Input (Pa·s)Reference equivalent (Pa·s)
11
55
1010
2525
5050
100100

Compare one Pa·s with other units

Target unitEquivalent of 1 Pa·sDefinition guide
Millipascal seconds (mPa·s)1000Read definition
Poise (P)10Read definition
Micropascal seconds (µPa·s)1000000Read definition

Resistance to shear in SI base terms

The pascal second, symbol Pa·s, is the coherent SI unit of dynamic viscosity. It is a pressure multiplied by a time, which equals newton seconds per square meter and kg·m⁻¹·s⁻¹. Viscosity enters Newton law of viscous flow, where shear stress equals viscosity times the velocity gradient across the fluid. A fluid with a viscosity of 1 Pa·s needs a shear stress of 1 Pa to keep layers sliding at a gradient of one meter per second per meter. The unit has no special name of its own in the SI, which is why it is written as a product. The same dimension appears in lubrication, blood flow, food processing and polymer melts, so one unit can serve them all.

Everyday fluids on a Pa·s scale

Water at 20 °C has a dynamic viscosity of about 1.002 mPa·s, and at 25 °C it falls to about 0.890 mPa·s, so temperature changes it noticeably. Air at 20 °C is about 18.1 µPa·s, nearly 55 times less viscous than water. Blood is typically near 3 to 4 mPa·s, olive oil is about 0.08 Pa·s, and glycerol is about 1.4 Pa·s at 20 °C. Honey spans roughly 2 to 10 Pa·s depending on moisture and temperature, and many molten polymers are in the range of hundreds or thousands of Pa·s. Each of these values moves with temperature, and for non-Newtonian fluids such as ketchup it also depends on how fast the fluid is being sheared.

Temperature and shear rate change the answer

A viscosity value is only meaningful with the temperature it was measured at. Liquids generally thin as they warm, and gases do the opposite, becoming more viscous with temperature. Water at 0 °C is about 1.79 mPa·s, whereas at 100 °C it is near 0.28 mPa·s, a six-fold change. Non-Newtonian materials need a shear rate as well. A paint that appears thick in the can can be thin under a brush. Instrument manuals report apparent viscosity in Pa·s or mPa·s together with spindle, speed and temperature. Recording those conditions beside the number matters more than the number of digits, and a converted figure carries the same conditions as the original.

Kinematic viscosity needs a density

Kinematic viscosity equals dynamic viscosity divided by density, so its SI unit is m²/s and it describes how momentum diffuses, rather than how much force a flow needs. For water near 20 °C, 1.002 mPa·s divided by a density of 998.2 kg/m³ gives 1.004 × 10⁻⁶ m²/s, which is about 1 cSt. A pascal second cannot be changed into a stokes or square meter per second without the density of the fluid. Oil at 0.087 Pa·s and 870 kg/m³ comes to 1.0 × 10⁻⁴ m²/s, or 100 cSt. Product datasheets list both forms, so the label m²/s or cSt signals that a density step is needed and a pure unit factor will fail.

Reynolds number and pipe flow

Pascal seconds feed directly into the Reynolds number, which compares inertial and viscous forces: Re equals density times velocity times diameter divided by dynamic viscosity. For water at 20 °C, taking a density of 998.2 kg/m³, a speed of 1 m/s and a pipe diameter of 25 mm, the result is about 24,900, which is turbulent flow. The same pipe carrying glycerol at 1.4 Pa·s and 1,260 kg/m³ gives a Reynolds number of about 22, well within laminar flow. That example is illustrative, but it shows why viscosity in correct units matters. A factor-of-ten error in Pa·s changes the Reynolds number tenfold and can move a design from one flow regime to another.

Connections to poise and centipoise

The older CGS unit is the poise, and 1 P equals exactly 0.1 Pa·s. The centipoise, cP, is 0.001 Pa·s, which is the same as one millipascal second. This means a viscosity in mPa·s has the same number as in cP, and 1.002 mPa·s is 1.002 cP, 0.01002 P and 0.001002 Pa·s. The Computandum converters list these pairs directly, including Pascal seconds to Poise at 10, Pascal seconds to Centipoise at 1,000, Pascal seconds to Millipascal seconds at 1,000 and Pascal seconds to Micropascal seconds at 1,000,000. Honey at 5 Pa·s is therefore 50 P or 5,000 cP. Lab reports still use cP in older literature, so conversion is common.

Where Pa·s appears in industry

Lubricant makers, food scientists and pharmacists record viscosity in Pa·s or mPa·s. Rotational viscometers report in these units, and ISO 3104 and ASTM D445 govern kinematic viscosity of petroleum products by capillary tubes, with dynamic viscosity found by multiplying by density. Coatings and inks are specified in mPa·s at a stated shear rate, and 3D printing resins, adhesives and injection-molded plastics are compared the same way. Syringe-delivered medicines depend on viscosity for the force needed to push them through a needle, and a fluid of 20 mPa·s needs about twenty times the pressure of water at the same flow rate in the same needle under laminar conditions.

Writing Pa·s and avoiding Pa/s

The correct symbol is Pa·s with a middle dot or a thin space, and Pa s is also accepted by the SI Brochure. Writing Pas, PaS or Pa/s changes the meaning or loses it. Pa/s would be a rate of pressure change. The Greek letter eta or mu stands for dynamic viscosity in equations, and nu for kinematic viscosity, which are different quantities. In some sources mu is the symbol for both viscosity and for the micro prefix, so a reading of µPa·s needs attention to which meaning applies. The label millipascal second shortens to mPa·s, and a capital M would mean megapascal seconds, a value that no ordinary fluid reaches. Checking the prefix case prevents errors of a factor of a billion. Instrument printouts sometimes show cP, mPa·s and Pa·s side by side, and the safest habit is to copy the unit with the number into every table. A viscosity quoted as 350 without a unit is useless, since it could be 350 cP, a thick syrup near 0.35 Pa·s, or 350 Pa·s, a paste that barely flows.

Precision and checking

  • Keep source viscosity precision.
  • Retain temperature and other stated conditions.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →