A property with two unit families
Dynamic viscosity measures a fluid's resistance to shear, the ratio of shear stress to the rate of shear. The SI unit is the pascal second. Older CGS literature, and a lot of industry practice, use the poise and the centipoise. Paint, oil, food and polymer data sheets often quote centipoise, while engineering calculations and newer standards use pascal seconds or millipascal seconds. A formula for pressure drop in a pipe expects Pa·s, so a viscosity from a data sheet in cP must be converted first. This page does the conversion between five units and stays within dynamic viscosity. Software that reports viscosity in mPa·s from a rheometer can therefore be compared with a datasheet in cP without any arithmetic, once the temperature matches.
How the five units relate
One pascal second equals 10 poise, 1,000 centipoise, 1,000 millipascal seconds and 1,000,000 micropascal seconds. The centipoise and the millipascal second are the same size, so a value in cP is numerically identical in mPa·s, which is the convenient link between the old and new systems. The poise is named for Jean Léonard Marie Poiseuille, who studied flow in tubes. The page converts through Pa·s, so 1.5 P becomes 0.15 Pa·s and then 150 cP. Because every factor is a power of ten, the results are exact up to display rounding. The micropascal second is the thousandth part of a millipascal second, so 1,000 µPa·s equals 1 mPa·s.
The default ten pascal seconds
Entering 10 Pa·s returns 10,000 mPa·s, which is also 10,000 cP and 100 poise. That is a thick liquid, similar to a heavy syrup or a viscous resin, and far above water. The comparison is the usual way to judge a result. Water at 20 °C is about 1.0 mPa·s, so 10 Pa·s is roughly ten thousand times as viscous. The page does not know the fluid, so you decide whether a figure is plausible. A number that is off by a factor of 1,000 often signals that Pa·s and mPa·s were interchanged. In poise the same value is 100 P, and in micropascal seconds it is 10,000,000 µPa·s.
Typical values to compare against
Water at 20 °C is close to 1.002 mPa·s, and at 25 °C close to 0.89 mPa·s. Air at 20 °C is about 18.1 µPa·s, which is 0.0000181 Pa·s. Glycerol at 20 °C is about 1.41 Pa·s, or 1,410 cP. Olive oil is roughly 80 mPa·s at room temperature, and whole blood at body temperature is commonly quoted around 3 to 4 mPa·s. Honey spans several pascal seconds depending on type and temperature. These figures are indicative values from reference tables, and your sample may differ, especially in temperature. A 10 percent sugar solution is only slightly above water, while engine oils at room temperature run to hundreds of millipascal seconds.
Temperature changes the number
Viscosity of liquids falls steeply as temperature rises, and gas viscosity rises slowly. A syrup that pours at 40 °C can be nearly solid in a refrigerator. A data sheet quote of 500 cP is meaningless without the temperature at which it was measured, and for many fluids also the shear rate. The page converts units and does not adjust for temperature or shear. If you compare two sources, make sure they refer to the same temperature before concluding that one fluid is thicker than the other. As an illustration, the viscosity of water falls from about 1.79 mPa·s at 0 °C to about 0.28 mPa·s at 100 °C, a drop of more than 80 percent.
Dynamic versus kinematic viscosity
Kinematic viscosity is dynamic viscosity divided by density, with SI unit m²/s and the CGS stokes, where 1 cSt is 10⁻⁶ m²/s. The two differ and must not be swapped without the density. A liquid with a dynamic viscosity of 100 mPa·s and a density of 850 kg/m³ has a kinematic viscosity of about 1.176 × 10⁻⁴ m²/s, which is 117.6 cSt. For water, near 1 g/cm³, cP and cSt are nearly equal, which causes people to assume they always are. This page converts dynamic units only. Use a density to move to kinematic viscosity. The unit pair to remember is the poise for dynamic and the stokes for kinematic, with 1 St equal to 1 cm²/s.
Micropascal seconds for gases
Gases are thin, and their viscosity is conveniently expressed in micropascal seconds. Air at 20 °C is about 18.1 µPa·s, and hydrogen is lower at about 8.8 µPa·s. Converting 18.1 µPa·s gives 0.0000181 Pa·s, or 0.0181 mPa·s, or 0.000181 poise. Reading gas data in cP is awkward because of the many leading zeros, which is why the micro unit exists. In gas flow calculations for pipes or lubrication, keep the viscosity in Pa·s with the other SI inputs, and use the page to bring catalog values into line. In poise, air at 20 °C is about 0.000181 P.
Using the converted value
After conversion, the viscosity enters formulas in Pa·s. The Poiseuille law for laminar flow in a tube gives the volumetric flow rate proportional to the pressure drop and the fourth power of the radius, and inversely proportional to the viscosity, so a mistake of 1,000 in viscosity gives a result off by 1,000. Reynolds number also needs viscosity or its kinematic form. Run the conversion before you start the calculation, write the unit with the value, and keep the data sheet reference so that the temperature stays attached to the number. A worked case helps. A fluid listed at 250 cP is 0.25 Pa·s, and the same pipe and pressure drop would carry only one quarter of the flow it would at 62.5 cP.
Temperature and shear rate effects on viscosity
The page converts the unit of a dynamic viscosity you provide. It does not estimate viscosity from composition, correct for temperature, treat non-Newtonian behavior, or convert to kinematic viscosity. Many fluids, such as paints, ketchup and polymer melts, have a viscosity that depends on shear rate, and a single number describes only one condition. The factors are exact powers of ten, so differences from another source come from rounding or from a different measurement condition. A shear-thinning fluid may read 5,000 cP at a low shear rate and 500 cP at a high one, and both values are correct for their own condition.