Reading older viscosity tables
Many reference books, chemistry handbooks and legacy specifications still list viscosity in poise or centipoise, the units of the CGS system. A student working through an older textbook problem, or an engineer reading a decades-old data sheet, may need to compare those values with results from software that reports pascal-seconds. This page multiplies the SI figure by 10 to give poise. The step is short, yet it is a typical place for slips, because people often remember that 1 cP is 1 mPa·s and then forget the factor for the unit one hundred times larger. Having the page confirm the digits helps when documents from two eras sit on the same desk.
A factor of ten
One poise is defined as one gram per centimeter per second, which equals 0.1 Pa·s. Therefore 1 Pa·s equals 10 P. The formula is P = Pa·s × 10. By hand, move the decimal point one place to the right: 0.8 Pa·s is 8 P, and 2.5 Pa·s is 25 P. For the reverse, divide by 10, so 3 P is 0.3 Pa·s. The relation with the centipoise is a factor of 100, so 1 P equals 100 cP and 1 cP equals 0.01 P. NIST SP 811 lists the poise as a CGS unit that is not part of the SI, along with the conversion to the pascal-second, and good practice is to state the SI value alongside it.
Ten pascal-seconds in poise
The page opens with 10 Pa·s and returns 100 P. A fluid at that viscosity is very thick, closer to a paste than to a pourable syrup. For a lighter case, 0.001 Pa·s, the viscosity of water near 20 °C, is 0.01 P, and olive oil at about 0.08 Pa·s is 0.8 P. The poise suits mid-range fluids badly, since water is a hundredth of a poise, which is why practitioners moved to the centipoise. The values on this page show why: small numbers with leading zeros for common liquids, and larger numbers only for heavy materials. If your fluid is thin, consider using the centipoise or millipascal-second page instead.
Textbook problems in CGS units
Physics and chemistry courses that use centimeters, grams and seconds quote viscosity in poise, force in dynes and pressure in dyne per square centimeter. A problem might give a lubricant viscosity of 0.9 P and ask for pressure drop in a small gap. Converting to 0.09 Pa·s lets you use SI for the rest of the work, with lengths in meters and pressures in pascals. The reverse is useful when a lab report must match a source in CGS. Keep a consistent system through the whole calculation, since mixing 0.09 Pa·s with lengths in centimeters leads to a result that is off by powers of ten, and the error can be invisible in the final number.
Cross-checking with centipoise
A simple way to confirm a result is to go through the centipoise. Multiply Pa·s by 1,000 for cP, then divide by 100 for P. For 0.35 Pa·s, that gives 350 cP and 3.5 P, which matches 0.35 × 10 = 3.5. The same path works in the other direction: 7 P is 700 cP and 0.7 Pa·s. If a catalog lists several fluids in different units, converting all of them to the same one before comparing avoids ranking errors. A grease at 12 P and a resin at 900 cP, for instance, are 1.2 Pa·s and 0.9 Pa·s, so the grease is thicker, which is not obvious from the raw numbers.
Common confusions with poise and poiseuille
The poise and the poiseuille are different units. The poiseuille (Pl) is an alternative name for the pascal-second in some French usage, so 1 Pl = 1 Pa·s = 10 P. The word poise on a label always refers to the CGS unit, which is 0.1 Pa·s. Another trap is the stokes, a unit of kinematic viscosity measured in cm²/s, which is not interchangeable with the poise. One stokes equals 10^-4 m²/s, and the relation to the poise involves density, since kinematic viscosity equals dynamic viscosity divided by density. Check the dimension on the label before you convert, and use this page only for dynamic viscosity.
Heavy materials where poise still appears
Glass and polymer melts, bitumen and some lava or magma models quote viscosity in poise or in logarithms of poise, since values span many orders of magnitude. For a polymer melt at 10,000 P, the SI equivalent is 1,000 Pa·s. Glass at the working point is often defined near 10^4 P, which is 10^3 Pa·s. Those materials sit far beyond the range of ordinary liquids, and a conversion by a factor of 10 is easy to apply but important to state in documents. Whenever a source writes log viscosity, check whether the logarithm is of poise or of Pa·s, because the two differ by exactly one in the exponent.
Reporting both units
When a document must be readable by both CGS and SI users, give the SI value first and the poise value in brackets: 0.35 Pa·s (3.5 P). Note the temperature, since viscosity changes with it. For an instrument that reports in poise, such as an older cone-and-plate viscometer, record the original reading and the converted one in separate columns. If the two numbers are rounded, use enough digits that converting back returns the original. The page shows many digits, so you can choose the rounding that fits your needs and keep a note of the conversion factor of 10 in the method. For a table of several fluids, a three-column layout with poise, centipoise and pascal-seconds side by side lets a reader move between the old and new unit without a calculator, and it makes any entry that breaks the pattern easy to spot.
A pump choice needs more than a viscosity in poise
Moving a viscosity from Pa·s to poise changes the unit and the digits, and nothing about the fluid. It does not measure viscosity, correct for temperature or shear, convert to kinematic units or decide whether a fluid suits a pump. Use the supplier's data and the relevant standard for those tasks, and treat the converted value as a restatement of the number you entered.