Formulas that need SI viscosity
Pressure drop in a pipe, film thickness in a bearing and the Reynolds number of a flow are all written for viscosity in pascal-seconds. A value from an older table, a handbook or a viscometer set to poise has to be converted before it goes into the formula, or the result will be wrong by a factor of ten. This page multiplies a poise value by 0.1 and returns pascal-seconds. It also converts the other way, so an SI value can be restated in poise when a source uses CGS units. The step is small, and it is one of those conversions where a missing factor of ten is easy to make and hard to spot afterward. The results of a flow calculation often look plausible even when the viscosity was off by ten.
Gram per centimeter-second to kilogram per meter-second
One poise is one gram per centimeter per second. Writing grams as 10^-3 kg and centimeters as 10^-2 m gives 10^-3 / 10^-2 = 0.1 kg/(m·s). A pascal-second is one kilogram per meter per second, and also one newton-second per square meter, so one poise equals 0.1 Pa·s. The formula is Pa·s = P × 0.1, and the factor is exact. By hand, move the decimal point one place left. A value of 2 P is 0.2 Pa·s, and 0.5 P is 0.05 Pa·s. A result larger than the input means the units are reversed, because the pascal-second is ten times larger than the poise.
Ten poise is exactly one pascal-second
The default of 10 P returns 1 Pa·s. This is a convenient reference for a quick test of the page, since the answer is a round number. A liquid with a viscosity of 1 Pa·s is about a thousand times thicker than water, and a stirred sample of it flows slowly from a spoon. The reverse is also useful: water at 20 °C is about 0.001 Pa·s, which is 0.01 P. If your page returns something other than 1 for 10 P, check that the source is poise and the target is pascal-seconds, and that the value was typed without a stray digit.
Pressure drop for a viscous liquid in a tube
For laminar flow in a round tube, the pressure drop is 8 × viscosity × length × flow rate / (π × radius⁴). Take a liquid of 2 P, which is 0.2 Pa·s, in a tube 2 m long with a radius of 0.01 m and a flow of 10^-5 m³/s, which is 10 mL/s. The drop is 8 × 0.2 × 2 × 10^-5 / (π × 10^-8), about 1,019 Pa, or 1.02 kPa. If someone entered 2 as the viscosity without converting from poise, the result would be ten times too large. The page does not compute the pressure drop. It supplies the unit step that comes before it.
Checking that the flow is laminar
The tube formula above holds for laminar flow. In the same example the cross-section is π × 0.01² = 3.14 × 10^-4 m², so the mean speed is 10^-5 / 3.14 × 10^-4 = 0.0318 m/s. With an illustrative density of 900 kg/m³ and a diameter of 0.02 m, the Reynolds number is 900 × 0.0318 × 0.02 / 0.2 = 2.9, far below the roughly 2,000 where laminar flow starts to break down. A viscosity left in poise instead of pascal-seconds would give a number ten times too small and the wrong sense of the regime. Convert first, then compute. The same applies to a lubrication check, where the film thickness scales with viscosity and a unit slip gives a bearing that looks ten times better or worse than it is.
Pa·s, N·s/m² and kg/(m·s)
All three expressions name the same unit. The pascal-second is a pressure times a time, and a newton-second per square meter and a kilogram per meter per second are the same thing written in other base units. A pressure in pascals is a different quantity, and a reading in Pa without the second is not a viscosity. The unit lists on this page include the pascal-second and its prefixed forms, so you can switch the target and read the same viscosity as 1,000 mPa·s or 1,000,000 µPa·s. Writing the unit in full in a spreadsheet header avoids the confusion between Pa, Pa·s and a kinematic viscosity in m²/s.
Glycerin as a worked reference
Glycerin at 20 °C has a viscosity of about 1.41 Pa·s. Converted to poise, it is 14.1 P, which is the value a CGS handbook would list. Pure glycerin changes quickly with temperature and with the small amounts of water it absorbs, so a value in a table applies only at the stated conditions. Using 14.1 P and the page gives back 1.41 Pa·s, a good check on the direction of the step. Honey, silicone fluids and heavy oils cover the range from about 0.1 to several hundred Pa·s, and a datasheet gives the real figure for a particular product at the working temperature.
Going back from pascal-seconds to poise
Select pascal-seconds as the source and poise as the target to convert in the other direction. A value of 0.25 Pa·s is 2.5 P, and 0.001 Pa·s, the viscosity of water at about 20 °C, is 0.01 P. The factor is 10. A table that mixes poise, centipoise and pascal-seconds needs one unit per column, and a header such as viscosity in Pa·s at 20 °C. When you cite a figure from an old source, give the original unit and the converted value together so that a reader can verify the step and find the source. Where a handbook gives viscosity at several temperatures, convert the whole column with the same factor, and keep the temperature column next to it.
A unit change and nothing more
The page changes the unit of a viscosity value. It does not know the temperature, the shear rate or the density, and it cannot say whether a flow is laminar or whether a pump will cope. For design work, use the fluid data for your operating conditions and the method that your field uses. The factor of 0.1 is exact, so a surprising result almost always comes from a swapped pair of units, a lost digit or a source value that was a kinematic viscosity in cSt or m²/s and not a dynamic one. Check the nature of the quantity before you doubt the arithmetic.