SI datasheets for pumps, coatings and chemicals
Pump datasheets, safety data sheets for chemicals and pharmaceutical specifications give viscosity in millipascal-seconds, because the SI is the standard in those documents. Some older handbooks and laboratory tables still list the same property in poise. A technician who matches a liquid against a pump limit, or a student who compares a textbook table with a modern datasheet, needs both in one unit. This page multiplies a value in poise by 100 and returns mPa·s. It also converts in the other direction, so a datasheet value can be restated in poise when a reference table is in CGS units. The conversion is short and exact. It does not depend on the liquid, so the same factor serves water, oil and paint alike.
Why one poise is a hundred millipascal-seconds
A poise is one gram per centimeter per second. In SI base units that is 10^-3 kg over 10^-2 m times one second, which is 0.1 kg/(m·s), or 0.1 Pa·s. A millipascal-second is 10^-3 Pa·s, so one poise equals 0.1 / 0.001 = 100 mPa·s. The formula is mPa·s = P × 100, and the factor is exact. By hand, move the decimal point two places right. A value of 0.4 P is 40 mPa·s, and 12 P is 1,200 mPa·s. The numbers match those in centipoise, because 1 cP equals 1 mPa·s, so a table in either unit gives the same figure.
Ten poise as one pascal-second
The page opens with 10 P and returns 1,000 mPa·s, which is 1 Pa·s. That is a liquid roughly a thousand times thicker than water, in the range of a thin syrup or a light gel. If a datasheet gives a pump limit of 1,000 mPa·s, then the default describes a fluid at that limit. A result smaller than the input means that the units were reversed, since the millipascal-second is the smaller unit and the number must grow. The default is a quick check on the direction of the conversion: 1 P must give 100, and 10 P must give 1,000.
Water and ethanol near room temperature
Water at 25 °C has a viscosity of about 0.89 mPa·s, which is 0.0089 P. Ethanol at the same temperature is about 1.07 mPa·s, or 0.0107 P. Water at 20 °C is close to 1.0 mPa·s, and at 0 °C it is about 1.79 mPa·s, so a quoted value needs its temperature. Entering 0.0089 poise on this page returns 0.89 mPa·s. Handbook values like these help you check that a viscometer is reading a familiar liquid correctly before you trust it on a sample. Values are approximate, and a handbook or a certified reference liquid gives the figure for a calibration. Laboratories often keep a standard oil of known viscosity for this purpose and record its value in mPa·s with the temperature.
A hydraulic oil from a kinematic grade
Oil grades such as ISO VG 46 are defined by a kinematic viscosity of 46 cSt at 40 °C. To get the dynamic viscosity, multiply by the density. With an illustrative density of 0.87 g/cm³, the dynamic viscosity is 46 × 0.87 = 40 mPa·s, which is 0.4 P. A pump datasheet that states a limit in mPa·s therefore needs this conversion before it can be compared with the oil label. The page performs only the poise to millipascal-second step. The density and the kinematic value come from the oil datasheet, and both must be taken at the same temperature as the viscosity.
Pump limits and viscous liquids
Centrifugal pump curves are drawn for water, and a more viscous liquid lowers the flow and head and raises the power needed. Positive displacement pumps handle thicker fluids, and their datasheets state a maximum viscosity in mPa·s. A sales sheet in poise or in older units has to be converted before it can be compared. The effect on the pump comes from the manufacturer correction method, which this page does not apply. It gives you the number in the unit the datasheet uses. When a fluid is close to a pump limit, ask the manufacturer, and check whether the viscosity is given at the operating temperature and not at 20 °C.
Coatings and spray equipment
Paint and coating sheets may state an application viscosity, for example 200 mPa·s, which is 2 P, as an illustrative figure. A spray gun is designed for a viscosity window, and a thicker product has to be thinned or heated. A flow cup gives a time in seconds that must be converted to a viscosity with the cup constants. A rotational viscometer reads in mPa·s or cP directly. The page converts a viscosity that you already have. It does not turn a cup time into a viscosity, and it cannot say whether a product will spray well. Follow the thinning rules on the product data sheet, and record the temperature of the product at the time of the reading, because a few degrees can change the viscosity of a coating by ten percent or more.
Back from millipascal-seconds to poise
Select millipascal-seconds as the source and poise as the target for the reverse step. A value of 85 mPa·s is 0.85 P, and 1,200 mPa·s is 12 P. The factor is 0.01. Because the figures are so close to those in centipoise, mistakes are rare, but the units differ in their symbols, and a column header should name the unit in full. A frequent slip is to confuse mPa·s with Pa·s, which is a factor of 1,000 and leads to values that are far out of range for the liquid. Compare each result with a familiar liquid such as water at about 1 mPa·s.
Temperature and shear stay with the measurement
A viscosity value belongs to a liquid at a stated temperature and, for non-Newtonian liquids, at a stated shear rate. The page converts the unit of a number and does not know either. It does not predict how a fluid will flow or how a pump will perform. Since the factor of 100 is exact, a mismatch with a published figure usually comes from a different temperature, a different test method or a unit mix-up between dynamic and kinematic viscosity. Before you convert, check that the source is a dynamic viscosity, and keep its temperature in your notes.