Why poise is still on labels
The poise is the cgs unit of dynamic viscosity, and it persists in paint, ink, adhesive and food specifications, in older standards and in viscometer manuals. Modern instruments often show mPa·s, but a customer specification may still ask for a value in poise or centipoise. This page multiplies the millipascal-second figure by 0.01 and gives poise, so 250 mPa·s becomes 2.5 P. Converting once at the start of a job prevents a mismatch between the datasheet from a supplier and the acceptance range written in a purchase order years ago. Where a test method names its unit, report in that unit and give the SI value in parentheses. A typical example is a printing ink with an acceptance window of 2.0 to 3.5 P, which is 200 to 350 mPa·s, checked on a rotational viscometer at a stated temperature and spindle speed. Entering the limits once and writing both units on the batch record keeps operators from reading a 250 mPa·s result as out of range.
How poise relates to the pascal-second
One poise equals 0.1 pascal-second, and one centipoise equals 0.01 poise. Since 1 Pa·s is 1,000 mPa·s, a poise is 100 mPa·s, and a millipascal-second is 0.01 P. The factor follows from the definition of the poise as one dyne-second per square centimeter and the exact relation between the dyne and the newton, 1 dyn = 10^-5 N. NIST SP 811 lists the poise with the factor 0.1 Pa·s. The conversion is therefore exact. The default of 10 mPa·s gives 0.1 P, and the same value in centipoise is 10 cP, equal to the number of millipascal-seconds.
Ten, a hundred and a thousand
The page gives 0.1 P for the default of 10 mPa·s. A value of 100 mPa·s converts to exactly 1 P, and 1,000 mPa·s converts to 10 P. Water at 20 degrees Celsius, near 1.002 mPa·s, comes to 0.01002 P, about one centipoise. A coating at 250 mPa·s is 2.5 P, and an adhesive at 12,000 mPa·s is 120 P. The numbers show why the centipoise was popular, since water sits near 1 cP and most liquids fall between 1 and 10,000 cP. Poise itself suits thicker materials such as inks and resins, where results in the tens or hundreds are common.
Centipoise as the bridge
Many specifications use centipoise rather than poise, and the centipoise is numerically equal to the millipascal-second. A paint listed at 1,500 cP is 1,500 mPa·s and 15 P. If a data sheet gives centipoise and your formula needs pascal-seconds, divide by 1,000. If it gives centipoise and your report needs poise, divide by 100. The page converts mPa·s to P directly, so use the number of centipoise as the number of millipascal-seconds when you enter it. This shortcut avoids a second tool and reduces the chance of a mistake with the poise prefixes, which many people find confusing. As a worked case, a varnish listed at 450 cP is 450 mPa·s, which the page gives as 4.5 P, and 0.45 Pa·s in SI. All three figures describe the same fluid, and writing them together on the batch sheet avoids disputes with a supplier who works in another unit.
Converting poise to millipascal-seconds
Select poise as the source and millipascal-seconds as the target to multiply by 100. A value of 0.35 P gives 35 mPa·s, and 4 P gives 400 mPa·s. A coating specified at 5 to 8 P corresponds to 500 to 800 mPa·s, and the same range in pascal-seconds is 0.5 to 0.8. When you receive a specification in poise and your viscometer reads mPa·s, convert the limits once and write them on the test form. Check that the temperature and the spindle or cup in the specification match your test, as viscosity depends strongly on both. Most paint and ink methods fix the temperature at 23 or 25 degrees Celsius, and a sample read at 15 degrees will look thicker than it is.
Viscometers and cup methods
Rotational viscometers report in mPa·s or cP directly. Flow cups, such as Ford or Zahn cups, report efflux time in seconds, which is converted to centistokes or centipoise by a chart or formula supplied with the cup. A chart value in centipoise equals the same number of mPa·s, and the page then gives the poise value. Since a cup measures kinematic viscosity in most charts, the conversion to dynamic viscosity needs the density. Keep track of which quantity each number represents. Ink and paint makers often record both the cup time and the calibrated viscosity for a batch.
Poise, stokes and why they are different
The stokes is the cgs unit of kinematic viscosity, in square centimeters per second, and 1 St equals 10^-4 m²/s. The poise measures dynamic viscosity. The two are related by density: kinematic equals dynamic divided by density. For water, with a density near 1 g/cm³, 1 cP is about 1 cSt. For mercury or heavy oils the two numbers differ by the density. A table that lists poise next to stokes is easy to misread, so check the header. This page converts dynamic viscosity only, and a stokes figure needs the fluid density first.
Writing the unit correctly
The symbol for poise is P, with a capital letter, and the pascal is Pa. A value written as 0.1 P is one tenth of a poise, whereas 0.1 Pa is a pressure. In a hurried table it is easy to see Pa·s as P, a tenfold slip. Centipoise uses cP, and a lowercase cp may be read as a count. Write the unit out at the first mention, keep one unit per column, and include the temperature. The page shows the unit symbols beside the result so that the output can be copied together with its unit.
Batch limits and the poise label
The page converts a dynamic viscosity between millipascal-seconds and poise. It does not adjust for temperature, convert kinematic to dynamic values, or decide whether a coating or fluid meets a specification. Viscosity depends on the temperature, the shear rate and the instrument, and acceptance limits from a supplier or a standard rely on a stated test method. Use the converted figure to compare like with like and follow the method named in the specification.