Viscometer readouts and product sheets

Rotational viscometers, flow cups and many coating and ink datasheets report viscosity in centipoise. Older handbooks and some laboratory tables list the same property in poise. A technician who reads a handbook value of 0.5 poise and needs to compare it with a viscometer reading of 48 cP has to bring both to one unit. This page multiplies a value in poise by 100 and returns centipoise. It also converts the other way, so a viscometer reading can be given in poise when a reference table uses that unit. The conversion is simple, and it is the one used in labs and in industries such as paint, food and lubricants.

Poise, centipoise and the factor of 100

One poise is one gram per centimeter per second, which equals 0.1 Pa·s. A centipoise is one hundredth of a poise, so 1 P = 100 cP and 1 cP = 0.01 P. The formula is cP = P × 100, and the factor is exact because the prefix centi means 10^-2. Moving the decimal point two places to the right does the conversion by hand. A value of 0.25 P is 25 cP, and 14 P is 1,400 cP. The unit is part of the CGS system and is outside the SI. NIST SP 811 lists the poise with its SI equivalent, which is why SI datasheets use the millipascal-second for the same quantity.

Ten poise as a thousand centipoise

The page opens with 10 P and returns 1,000 cP. For comparison, water at about 20 °C has a viscosity of roughly 1 cP, so the default describes a liquid about a thousand times thicker than water. That is in the range of a thick syrup. A result smaller than the input means the units were set in the wrong order, because the centipoise is the smaller unit and the number must grow by a factor of 100. The default is a handy reference. If you enter 1 poise and do not see 100, then the source and target units are not the ones you intended. Two more reference points: 0.5 P is 50 cP, and 0.01 P is 1 cP.

Water as the one-centipoise reference

Water is the usual reference for the unit, because its viscosity at 20 °C is close to 1 cP, which is 0.01 P. More precisely, it is about 1.0 cP at 20 °C, about 1.79 cP at 0 °C and about 0.28 cP at 100 °C. A value of 0.0179 P is therefore the viscosity of water near the freezing point. The strong temperature dependence is the reason a viscosity must always be quoted with a temperature. A paint can that thins in a warm room and thickens in a cold garage is behaving normally, and a viscometer reading means little without the temperature at which it was taken.

Glycerin and heavier liquids

Glycerin at 20 °C has a viscosity of about 1.41 Pa·s, which equals 14.1 P and 1,410 cP. Light machine oils fall in the range of tens to hundreds of centipoise, and honey and some syrups reach thousands, depending on the product and the temperature. These figures are approximate, and a datasheet for the exact product is the reliable source. Entering 14.1 poise on this page gives 1,410 cP, which agrees with the handbook value. The viscometer you use will have a stated range, and a reading near the ends of that range is less reliable than one in the middle. For a liquid this thick, check that the spindle and speed suit the sample, and let it reach the stated temperature before you read the dial.

Dynamic viscosity and centistokes

Centipoise measures dynamic viscosity. Centistokes, written cSt, measure kinematic viscosity, which is the dynamic viscosity divided by density. For a liquid with a density of 0.87 g/cm³, a viscosity of 90 cP corresponds to 90 / 0.87 = about 103.4 cSt. Oil grades and some lubricant datasheets give kinematic values, and paint and chemical sheets give dynamic ones. Converting between the two needs the density at the same temperature, which this page does not take. Make sure that the source describes a dynamic viscosity before you convert it from poise to centipoise, and use the density when a kinematic figure is the one you have.

Centipoise and millipascal-seconds are the same number

One centipoise equals one millipascal-second, so a value in cP and the same value in mPa·s are identical. A viscosity of 500 cP is 500 mPa·s, and it is also 0.5 Pa·s. SI-based datasheets in the chemical and pharmaceutical fields use mPa·s, while many US sources keep cP. The unit lists on this page include the pascal-second and its prefixed forms, so you can change the target after the first answer and read the same viscosity in SI. Mistakes happen when someone confuses a Pa·s value with one in mPa·s, a factor of 1,000, and a check against a familiar liquid such as water helps catch them.

Going back, and a note on abbreviations

Select centipoise as the source and poise as the target to convert in the other direction. A reading of 25 cP is 0.25 P, and 400 cP is 4 P. The abbreviation cP is sometimes written cps or cp, and cps can also mean cycles per second, so write the unit in full when you share a result. Capital P in cP stands for poise and a lowercase p alone could be misread as a different prefix. A table with a clearly labeled header, such as viscosity in centipoise at 25 °C, avoids most confusion. The labels on the page spell out each unit before the result.

Shear, temperature and what the number cannot show

Many liquids are not Newtonian. Paint, ketchup, blood and polymer solutions change their apparent viscosity with the shear rate, so a single number depends on the spindle and the speed of the viscometer. A reading must be accompanied by the temperature, the geometry and the rate. The page converts a stated value from poise to centipoise and says nothing about how it was measured. For quality control, follow the test method that your industry uses. Since the factor of 100 is exact, a mismatch with a published figure comes from a different temperature, a different test method or a unit mix-up, and not from the arithmetic.