Staying inside the CGS family

The centipoise and the poise belong to the same unit system, so converting between them is a matter of scale rather than of switching systems. Viscometer readouts, older handbooks and papers from before the SI took hold often give viscosity in poise, while paint, ink and food laboratories commonly read centipoise. A reading of 250 cP in a lab notebook has to match a chart in poise that lists 2.5 P. This page performs that single step, and it does it in either direction. Since both units are the same dynamic viscosity written at different sizes, the conversion needs no density or temperature input.

One hundred to one

The poise is defined as one dyne second per square centimeter, which equals one gram per centimeter second and 0.1 Pa·s. The prefix centi means one hundredth, so 1 cP = 0.01 P and P = cP × 0.01. The default 10 cP becomes 0.1 P, and 100 cP becomes 1 P. The conversion is exact and involves no rounding beyond display. Moving the decimal point two places to the left is all that happens. Water near 20 °C at about 1.0 cP is therefore about 0.01 P, a figure that shows why poise are inconvenient for thin liquids, and why the centipoise became the common working unit.

Viscometer manuals and product data sheets

Many rotational viscometer manuals and older lab notebooks print readings in poise, while the product data sheet next to them prints centipoise. A lotion measured at 12,000 cP is 120 P, a coating that a technician logs as 3.5 P is 350 cP, and a gear oil listed at 220 cP at the test temperature is 2.2 P. A cream logged at 45,000 cP is 450 P, and a fluid at 0.5 P is 50 cP, so the shift always moves two places. The related French unit poiseuille, symbol Pl, equals the pascal second, so 1 Pl = 10 P. Do not mix the two names, since a poise and a poiseuille differ by a factor of ten.

Converting plausible readings

A few conversions give a sense of range. A rotational viscometer reading of 250 cP is 2.5 P. Light oil at about 85 cP is 0.85 P. A 3,500 cP coating is 35 P, and a very thick paste at 100,000 cP is 1,000 P. Water at 0.89 cP, a value often quoted near 25 °C, becomes 0.0089 P. Each result is the input shifted two places. The numbers in poise look awkward for thin fluids and comfortable for heavy ones, which is partly why older paint and sealant sheets used poise, and why cP dominates for water-like liquids. A heavy honey near 10,000 cP is 100 P. Putting the two columns side by side in a table, with the temperature of each reading beside it, makes a good habit when you assemble data from several vintages of source material, since the poise column and the cP column then check each other.

From poise back to centipoise

Swap the menus to turn poise into centipoise by multiplying by 100. A viscosity of 2.5 P becomes 250 cP, and 0.01 P becomes 1 cP. This direction is needed when an old reference gives poise and a current instrument or datasheet is in cP. Remember that centipoise numbers are bigger than the same viscosity in poise. If the converted result is smaller than the input, the menus need switching. Because of the two-place decimal shift, a mistake of misplacing the point is easy, and the page gives a quick check against mental arithmetic when you are comparing several readings. Another trap is applying the SI relation by habit. A value in poise multiplied by 0.1 gives Pa·s, but a value in centipoise multiplied by 0.1 does not, so keep track of which of the two prefixes the number carries.

Capital letters and look-alike units

Poise is written P, and centipoise cP. The lowercase p is not used for poise. The stokes, St, and centistokes, cSt, are kinematic viscosity units named in the same style, and they measure how quickly a fluid flows under gravity, not how strongly it resists shear. A fluid at 100 cP is 1 P, but its kinematic viscosity in stokes depends on density, so 1 P does not equal 1 St. Capital P also stands for power in electrical work and for the prefix peta, and a document that mixes fields can contain all of these. Always check the unit context in a document before reading a bare P as poise, and prefer writing out poise on first use.

Precision and the viscometer behind the number

A conversion between prefixes is exact, but the reading it starts from is not. Rotational viscometers state accuracy as a percent of full-scale range, so a reading of 250 cP could be off by several cP depending on the spindle and speed. Keep the same significant digits after conversion, so 250 cP becomes 2.5 P, not 2.500000 P. Viscosity also depends strongly on temperature, and many fluids change with shear rate. Record the temperature and spindle conditions together with the poise figure. The conversion preserves what the instrument gave you and does not improve it.

Where this page stops

The page changes the size of the unit, nothing else. It does not convert to SI base units in this pair, which is the job of the centipoise to pascal second converter, and it does not convert kinematic viscosity. It also makes no statement about whether a fluid is suitable for a pump, process or coating line. Those decisions depend on temperature, shear rate and system design. Use the result as a clean restatement of a CGS viscosity, and cite the instrument, temperature and method in any report that depends on the number.

Sealants, adhesives and long numbers

Thick materials produce long numbers in centipoise. A construction sealant at 250,000 cP is 2,500 P, and a hot-melt adhesive at 1,000,000 cP is 10,000 P, which is 1,000 Pa·s. At those sizes poise keeps the line short. The converter handles such numbers as ordinary decimal shifts, but a calculator display may switch to scientific notation, so read the exponent carefully. A value like 1e6 cP means 1 followed by six zeros, not 1.6.