Cooling capacity and small heat sources

In the United States, air conditioners and chillers are sold by tons of refrigeration, a way to state how much heat the equipment can remove. A one-ton unit removes 12,000 BTU per hour. The heat that electronics add to a room is usually quoted in watts, and the smallest parts in nanowatts or microwatts. When a facilities manager or an installer wants to see whether the gadgets in a room change the cooling load, a common unit helps. This page converts nanowatts into tons of refrigeration. The result is a very small decimal for any single device, and it shows why the load of a sleeping sensor can be ignored in sizing. Homeowners, building technicians and students who meet both unit families on a single spec sheet can use the same page to cross-check a number before they quote it.

The size of a ton

The refrigeration ton comes from the heat needed to melt a short ton of ice in 24 hours. In current practice it is fixed at 12,000 BTU IT per hour, which is 3,516.85 W. The page applies TR = nW × 2.84345136094e-13, using the watt as the SI base and the International Table BTU of 1,055.05585262 J listed in NIST SP 811. A different ton, the metric ton of refrigeration, is about 3.86 kW and appears in some countries, so check which one a brochure uses. By hand, divide nanowatts by 10^9 to get watts, then by 3,516.85 to get tons. The two steps give the same result as the page.

Ten nanowatts in tons

With the default input of 10 nW, the page returns 2.8434513609399514e-12 TR, which is about 2.84 × 10^-12 tons. That number has eleven zeros after the decimal point, and e notation keeps it readable. A 1,000 nW input gives 2.84 × 10^-10 TR. These results make the point that a milliwatt-class device is irrelevant in cooling design. Even a thousand sensors at 1 µW each, a total of 1 mW, equal about 2.8 × 10^-7 TR, less than one millionth of a ton. In a report you can say the load is negligible and show the number to support it. For comparison, a single 100 W light bulb releases about 0.028 TR of heat, ten billion times the 10 nW default and still a minor part of one air conditioner.

Server racks and room cooling

The more useful direction starts from watts. A rack of servers drawing 10 kW releases nearly all of it as heat, which is 2.84 TR of cooling. A home office with a 300 W computer and monitor adds about 0.085 TR. A typical person at rest gives off about 100 W, or 0.028 TR. Adding these loads to the heat from sun, windows and appliances is part of a cooling load calculation, which a contractor does with a standard method such as the one published by ACCA or ASHRAE. The converter handles one number at a time and does not total the loads for you. Sum the watts first, then convert the total to tons or to BTU per hour so that you compare it with the equipment label in its own unit.

Reading a nameplate in tons

A residential air conditioner of 3 tons removes 36,000 BTU/h, which is 10,551 W of heat. The electricity it draws is much lower, often a third of that or less, because the compressor moves heat rather than creating it. The relation between cooling and electrical power is the efficiency rating, such as SEER or EER, and it differs between models. The tons figure on the nameplate describes cooling capacity under stated test conditions, and a 3 TR unit does not draw 10.5 kW. The page converts the capacity into other power units without adjusting for efficiency. Heat pumps add another wrinkle, since the same unit can deliver heating and cooling at different capacities, and the label should list each rating separately.

Going from tons to nanowatts

To express a capacity in nanowatts, set tons of refrigeration as the From unit and nanowatts as the To unit. One ton is about 3.51685 × 10^12 nW, and 2.5 tons is 8.79 × 10^12 nW. Nobody quotes air conditioners in nanowatts, but a database that stores all powers in one small unit might. If you check such a table, the ratio between a ton and a watt is 3,516.85, so a value for a 1 TR unit should have thirteen digits in nanowatts. A quick count confirms that the units were scaled correctly. Check also whether the capacity is cooling or electrical input, because brochures sometimes print both in the same table and the two differ by a large factor.

Sizing cautions and rules of thumb

Rules of thumb that quote a certain number of square feet per ton vary with climate, insulation and use, and they can lead to oversizing. An oversized unit cycles on and off, removes less humidity and may wear faster. A load calculation for the specific building is the accepted way to choose a size. Because tons come in steps of half a ton or so, the chosen unit rarely matches the calculation exactly. The page gives the unit conversion for a given power, so it helps compare numbers in different units but does not recommend a size for a room. Humidity, ventilation air, ductwork losses and the number of occupants all enter a proper load calculation.

Heat from electronics in sealed cabinets

An outdoor cabinet that holds telecom or control equipment must remove the heat its parts release. If a cabinet dissipates 600 W, the cooling needed is about 0.17 TR, or 2,047 BTU/h. Sleeping low-power parts add only tiny fractions to that total. Designers use the sum of the data sheet powers, a margin for solar load and an estimate of the efficiency of the cooling method. The converter helps if one list uses watts and another tons or BTU per hour, and the nanowatt entry only shows how small the low-power parts are. For installations, use manufacturer data and have a qualified installer check the work.

Capacity ratings shift with outdoor temperature

Cooling load calculations, equipment selection and the electrical consumption of an air conditioner are separate from the unit change. Capacity ratings depend on test conditions such as indoor and outdoor temperature, and real capacity shifts with the weather. Nameplate data and local codes govern installations, and a licensed professional should handle refrigerant and electrical work. A nameplate in tons gives cooling capacity, and the electrical input printed on the same plate is a different figure. For a 3 ton unit, the nameplate capacity is roughly 10.6 kW of heat removal, and any nanowatt figure sits many orders of magnitude below it.