Telemetry stores that count power in nanowatts

Some metering and telemetry systems keep every power reading as a whole number of nanowatts, so that very small loads and very large ones share one column without fractions. A building-automation export may then list a chiller capacity beside the standby draw of a tiny sensor. This page converts tons of refrigeration to nanowatts by taking 3,516.852842 W per ton and multiplying by 10^9. It is useful to people who write the import scripts, to students checking a unit chain and to analysts who need a consistent scale across a data set. The answers have thirteen or more digits, which the page shows in full for the default. Spreadsheet users should note that most programs keep about fifteen significant digits, so a plant of a few thousand tons already approaches that limit when counted in nanowatts.

From BTU per hour to nanowatts

The ton of refrigeration is defined as 12,000 BTU IT per hour. With 1 BTU IT equal to 1,055.05585262 J, that is 12,660,670.23 J per hour, or 3,516.852842 J per second, which is 3,516.852842 W. A nanowatt is 10^-9 W, so one ton is 3,516,852,842,067 nW. The page formula, nW = TR × 3516852842070, uses the same product with a rounded factor on display. The joule and the watt come from the SI, and the International Table BTU is tied to them by definition. By hand, multiply by 3,516.85 and then shift the decimal point nine places to the right.

Ten tons in nanowatts

The default 10 TR returns about 35,168,528,420,667 nW, or 3.517 × 10^13 nW. Some outputs show the last digits as .668, because the computer stores decimals in binary, and the meaningful value is the rounded integer. The same power is 35,168.5 W or 35.17 kW. The number is a good reference for testing import code: if a script returns 3.5 × 10^10 for 10 TR, it used microwatts, and if it returns 3.5 × 10^16, it applied the factor of one trillion. The leading digits 3.5168 stay the same in each case, so check the exponent before anything else. Writing the expected exponent in a comment next to the formula gives future maintainers an easy way to see whether a change broke the conversion.

How large a plant a double can store exactly

A 64-bit floating-point number holds whole numbers exactly up to 2^53, which is 9,007,199,254,740,992. In nanowatts that is 9,007,199 W, or 9.007 MW, which equals roughly 2,561 tons of refrigeration. A plant above that size, entered as an integer count of nanowatts in a spreadsheet or in JavaScript, may lose its final digits. A district cooling plant can exceed this size, so for such a system a 64-bit integer or a decimal type is the safer container. The check is quick on this page: enter the tonnage and see whether the result stays below 9 × 10^15.

Integer fields for nanowatt data

A signed 32-bit integer tops out at 2,147,483,647. Counted in nanowatts, that is 2.147 W, about 0.00061 tons of refrigeration. A device that stores power in nanowatts in 32 bits is suited to low-power electronics and cannot represent the heat load of a single server, let alone a plant. The ratio is a useful sanity check when a field is chosen for a data pipeline. If you plan to hold both a chiller and a microcontroller in the same column, plan on a 64-bit field. A 64-bit signed integer reaches 9.22 × 10^18 nW, which is 9.22 GW, or about 2.6 million tons. Few real assets approach that, so a 64-bit integer column is a safe default for mixed data.

From nanowatts back to tons

Select nanowatts as the source and tons of refrigeration as the target to reverse the calculation. A power of one watt, which is 1,000,000,000 nW, comes to about 0.000284 TR, and 3,516,852,842,067 nW is one ton. The page displays tiny results in scientific notation, such as 2.843 × 10^-4, and you should keep that form when you copy the number. If a column of results has no exponent and shows a long run of zeros, the cell format may be hiding the notation, so widen it or switch to a scientific format to avoid miscounting.

Heat removed, not electricity used

The ton of refrigeration measures the rate at which equipment removes heat. The electricity it uses is a separate quantity, and for a typical compressor-based machine it is a fraction of the heat moved, set by the coefficient of performance. A chiller removing 35.17 kW of heat with a coefficient of performance of 4, an illustrative value, draws about 8.79 kW. The conversion on this page applies only to the cooling side, so the nanowatt figure is thermal power. If you load electrical readings and cooling capacity into one table, keep a column for the type of power, or the data will mislead readers.

The definition behind 12,000

The ton of refrigeration is defined as 12,000 BTU IT per hour, a rate based on the heat absorbed when a short ton of ice melts over 24 hours, at about 144 BTU per pound. It is not a mass in this use. The International Table BTU gives the watt equivalent of 3,516.852842 W. Another BTU definition, the thermochemical one, differs by less than 0.1 percent, and a source that used it would give a slightly different number in the fourth digit. The page uses the IT definition throughout, so state that in any document where the result is audited. If your figures feed a billing or compliance report, include the factor 3,516.852842 W per ton in the method note. Keeping the result as an integer count of nanowatts, rather than a float, also makes sums across many assets reproducible between systems.

Reporting a thirteen-digit figure

A string of thirteen digits is easy to miscopy. Group the digits in threes, or write 3.517 × 10^13 nW. Add the unit symbol nW next to the number, because a missing symbol leaves open whether the value is in nanowatts or watts. When a result goes to a database, store the full number and apply rounding only for display. If a colleague asks how you got it, give the tonnage and the factor, for example 10 TR × 3,516.852842 W × 10^9. A reader who has the page can then repeat the step, and anyone with a calculator can confirm the first four digits.