A cooling-capacity unit for tiny loads
The ton of refrigeration is the unit that air-conditioning and chiller catalogs use for cooling capacity, the rate at which heat is removed. Microwatts describe the smallest heat loads and power levels in electronics and low-temperature physics. A conversion between the two is unusual, but it comes up when a table has to put a cryogenic cooling power next to a building cooling plant, or when a software tool insists on a single unit for heat flow. This page multiplies a value in microwatts by 2.84345136094e-10 and returns tons of refrigeration. The default 10 µW gives 2.84345136094e-9 TR. The converter changes the unit of a rate of heat flow. It does not size equipment or say how much cooling a space needs. Many countries quote cooling capacity in kilowatts, while North American catalogs still use tons and BTU per hour, which is why a chain of conversions through watts is so common.
Where the ton of refrigeration comes from
The unit has its roots in the ice trade. One ton of refrigeration is the rate of heat absorption that would melt one short ton of ice, 2,000 pounds, in 24 hours. The latent heat of fusion of ice is about 144 BTU per pound, so the heat absorbed is roughly 288,000 BTU in a day, which is 12,000 BTU per hour. The modern definition simply fixes the rate at 12,000 BTU per hour, using the International Table BTU, so the ice is no longer part of it. The definition is exact once the BTU is fixed. The unit is not an SI unit, and it should not be confused with a ton of mass. It is a rate of heat flow, the same kind of quantity as the watt. The ice-melting picture is a convenient memory aid: a plant delivering one ton of refrigeration would turn a short ton of water at 0 °C into ice in about a day, ignoring losses.
Building the conversion factor
One International Table BTU is 1,055.05585262 joules. Multiplying by 12,000 gives 12,660,670.23 J, the heat per hour, and dividing by 3,600 seconds yields 3,516.8528421 W. That is one ton of refrigeration in watts, or about 3.517 kW. To convert watts to tons, divide by 3,516.8528421, which is the same as multiplying by 2.84345136094e-4. A microwatt is 10⁻⁶ W, so the factor for microwatts is 2.84345136094e-10, as the page formula states: TR = µW × 2.84345136094e-10. The reverse factor is about 3,516,852,842 µW per ton. The BTU value comes from the International Table definition that NIST lists, and the arithmetic then follows exactly. Using the thermochemical BTU instead would change the fourth significant digit, which is why the unit label on the page specifies BTU IT. As a check, a rule of thumb of 12,000 BTU/h per ton and the figure of 3.517 kW per ton agree to four significant digits.
The default value
The default is 10 µW. Multiplying by 2.84345136094e-10 gives 2.84345136094e-9 TR, which is 0.00000000284345136094 TR. The number on screen may read 2.843451360939951e-9, which differs only in the last digits because of floating-point arithmetic. A check through watts: 10 µW is 0.00001 W, and 0.00001 divided by 3,516.8528 equals 2.8435e-9. If you obtain something near 10⁻⁶, you probably forgot to scale from microwatts to watts. If you obtain something near 10⁻¹¹, you may have used kilowatts per ton rather than watts per ton. The default is a quick test of both the prefix step and the ton step. The result is about three billionths of a ton, which expresses how small a microwatt is next to a household cooling system.
Tons of refrigeration in building systems
Air conditioners and chillers carry capacity ratings in tons. A residential split system often falls in the range of a few tons, and a three-ton unit corresponds to 36,000 BTU per hour, about 10.55 kW of heat removal. Commercial chillers run from tens to thousands of tons. Rating conditions matter. Capacity depends on the temperatures of the air or water entering and leaving the equipment, and nominal values are stated at standard rating conditions that differ between regions and product types. A ton is a measure of heat removed, not of electrical power consumed. A three-ton unit does not draw three tons of anything, and its electrical input is a separate figure that depends on efficiency. The converter works only with the heat flow number. Sizing a system is a separate engineering exercise based on a load calculation for the building, and rules of thumb that give square feet per ton vary too widely to apply without that calculation.
Why microwatts of cooling matter
In cryogenics, cooling power is often small and quoted in microwatts. A dilution refrigerator, the type used to cool quantum devices to a few millikelvin, may provide cooling power of the order of hundreds of microwatts at around 100 mK, depending on model, and far less at lower temperatures. Every wire entering the cold stage adds a tiny heat load, so designers count microwatts carefully. Converting such a value to tons of refrigeration looks odd, but it shows the contrast with building HVAC. A cooling power of 400 µW is 1.137380544376e-7 TR, a figure nobody would use in practice but one that makes the scale plain. The numbers are illustrative of the class of equipment and not specifications of a particular cryostat. The conversion only translates the unit. Heat leaks through support structures, instrumentation lines and radiation, and the sum of these loads must stay below the available cooling power at each temperature stage, which is why designers add them up in microwatts.
A worked example in both directions
Using 400 µW as an illustrative cooling power, multiply by 2.84345136094e-10 to get 1.137380544376e-7 TR. The same value in watts is 0.0004 W, and 0.0004 divided by 3,516.8528 reproduces the answer. For the reverse direction, one ton of refrigeration is 3,516.8528421 W, which is 3,516,852,842 µW once you scale by a million. A three-ton unit is then about 10.55 kW or 1.055 × 10¹⁰ µW. Because the page works in either direction, a round trip is a reliable check: convert 400 µW to tons, swap the units, and convert the result back. The original value should reappear to within floating-point noise. If it does not, check that both selections in the dropdowns are the units you intended. As another case, a 5 TR chiller is about 17.58 kW, or 1.758 × 10¹⁰ µW.
BTU per hour and the IT convention
The ton of refrigeration is defined through the BTU, and the BTU has several versions. The International Table BTU, abbreviated BTU IT, is 1,055.05585262 J. The thermochemical BTU is about 1,054.35 J, and the mean BTU is about 1,055.87 J. The differences are around a tenth of a percent, small but enough to matter in a precise conversion. The page uses BTU IT, as its dropdown labels show for BTU per hour. If your source uses a different BTU, the factor changes slightly. For most HVAC work the difference is negligible, because capacity ratings are rounded to the nearest few hundred BTU per hour. For a conversion that must be reproducible, note which BTU the source uses and keep it with the number. When a source gives watts directly, divide by 3,516.8528 to reach tons and you never need to know which BTU was involved, because the IT definition ties the ton to a fixed number of watts.
Heat removed versus electrical power used
Cooling equipment moves heat, and its efficiency is described by ratios such as the coefficient of performance, which is heat removed divided by electrical energy consumed. The energy efficiency ratio, EER, is the same idea in BTU per hour per watt. For an illustrative three-ton unit with an EER of 12, the electrical input is 36,000 BTU/h divided by 12, or 3,000 W. The cooling capacity in watts is about 10,551 W, so the unit moves roughly 3.5 times as much heat as the electricity it uses. That is not a violation of energy conservation, because the equipment pumps heat rather than creating it. The converter handles the heat flow side only. A conversion of the electrical input would use a different power unit and the same watt-based factor. Capacity is also not a fixed number. It falls as outdoor temperature rises, so a nominal rating describes one operating point only.
Cooling, heating and sign conventions
A ton of refrigeration measures the rate of heat removal. The same rate in the opposite direction, heating, can be quoted in BTU per hour or kilowatts, and the tons unit is seldom used for it. When a heat pump is rated, the cooling capacity is often given in tons and the heating capacity in BTU per hour. The conversion on this page does not care about direction. It scales the magnitude of a heat flow. In calculations that track heat balance, keep the sign convention of your source. If heat leaking into a cold stage is counted as positive, the cooling power needed has the same magnitude. Converting a magnitude changes nothing about sign, so you can apply the factor and add the sign back afterward.
Limits of the page
The converter is a unit change for a rate of heat flow. It does not size cooling equipment, estimate a building load, assess the performance of a refrigeration cycle or determine refrigerant properties. For equipment decisions, consult manufacturer data and the applicable standards. For the BTU and the definition of the ton, NIST Special Publication 811 is the reference. Use the converter for arithmetic, and keep the original unit alongside every converted value so that others can retrace the steps. Rates of heat flow here are magnitudes. Time-averaged and peak values are not distinguished, so say which one you are converting.