What the conversion does
Inductance values on component data sheets, RF design notes and simulation files use microhenries and nanohenries side by side. A power inductor for a switching regulator is typically listed in microhenries, while a trace, a bond wire or a small RF chip inductor is described in nanohenries. This converter changes one into the other so that a value copied from a catalog fits the unit a simulator expects. The default entry of 10 µH becomes 10,000 nH. Since the factor is a plain 1,000, the tool saves little arithmetic on its own, but it removes the risk of dropping or adding a zero, a mistake that, at a factor of 1,000 in inductance, shifts a resonant frequency by a factor of about 32. It also gives a quick check when you reverse the direction. The page converts the unit of the same inductance value. It does not choose an inductor for you.
The factor explained
The prefix micro means 10⁻⁶ and nano means 10⁻⁹. A microhenry is therefore 1,000 times larger than a nanohenry. To convert microhenries to nanohenries, multiply by 1,000, which matches the page formula nH = µH × 1000. For the reverse, divide by 1,000. The sequence of prefixes can be held in mind as steps of three decades: milli, micro, nano, pico. Going from micro to nano is one step down, so the number grows by a factor of 1,000. The SI Brochure from the BIPM lists these prefixes with exact values, so the relationship carries no tolerance. The henry itself is the SI derived unit of inductance, equal to one weber per ampere or one volt-second per ampere. The page does not need those definitions to work, but they explain why the unit scales cleanly.
The default example
The page begins with 10 µH. Multiplying by 1,000 gives 10,000 nH, as the formula suggests. The raw output on screen may display 9999.999999999998 because of floating-point arithmetic, and the intended result is 10,000 nH. That is the same inductance written with different digits. A sanity check uses the ratio rule: 10 µH is ten times the 1 µH reference, and 1 µH equals 1,000 nH. Another way to verify is to move the decimal point three places to the right, which changes 10 to 10,000. If your answer has only two or three digits, you probably divided instead of multiplying. For small inputs, the same logic applies: 0.5 µH is 500 nH, and 0.047 µH is 47 nH. Remember that this movement of the decimal is exact, not approximate.
What an inductor value represents
Inductance measures how strongly a conductor or coil resists a change in current. The voltage across an ideal inductor equals its inductance times the rate of change of current, v = L di/dt. A 10 µH inductor with current rising at 1 A per microsecond develops 10 V across it, since 10 × 10⁻⁶ H times 10⁶ A/s equals 10 V. The same inductor written as 10,000 nH gives the same result when the formula is evaluated in henries. This relationship is why inductor values in switching power supplies are chosen from the allowed current ripple and switching frequency. The unit conversion changes nothing about the physics. It only changes the digits you read, which is why mistakes in prefixes lead to errors by whole orders of magnitude in the computed voltage or ripple current.
Typical magnitudes in practice
Buck converter inductors commonly range from about 1 µH to 100 µH, with 4.7 µH, 10 µH and 22 µH among the standard values. Radio frequency chokes and matching components fall in the tens to hundreds of nanohenries. A straight wire or printed trace contributes inductance too, and a frequently quoted rule of thumb is about 1 nH per millimeter for a thin wire or bond wire, though the real figure depends on geometry and the return path. A 10 mm lead could add on the order of 10 nH, which is trivial next to 10 µH but significant next to a 47 nH RF part. That is where conversions to nanohenries become useful: parasitic and intentional values then appear in the same unit, and you can see at once whether the parasitic element is a small correction or a dominant term.
A resonance example
Resonant frequency of an LC circuit is f = 1 / (2π√(LC)). With L = 10 µH and C = 100 pF, the product LC is 10⁻⁶ times 10 times 10⁻¹² times 100 = 10⁻¹⁵ s², with a square root of about 3.1623 × 10⁻⁸ s. Multiplying by 2π gives 1.9869 × 10⁻⁷ s, and the reciprocal is about 5.03 MHz. If you mistakenly used 10 nH instead of 10 µH, the frequency would be 31.6 times higher, about 159 MHz. The conversion between microhenries and nanohenries is simple, but mixing them in a formula that expects henries leads to large errors. Always convert to henries before applying such formulas, or use a consistent set of units such as nH and pF with a frequency in GHz. The values here are illustrative.
Preferred values and tolerances
Catalog inductors follow preferred number series, so values like 4.7 µH, 0.22 µH and 0.068 µH are common. In nanohenries, those become 4,700 nH, 220 nH and 68 nH. Tolerances of 10 or 20 percent are typical for power inductors, and RF chip inductors can have tolerances of 2 to 5 percent. A nominal 10 µH part with a 20 percent tolerance may measure anywhere from 8 to 12 µH, or 8,000 to 12,000 nH. Inductance also changes with current, because magnetic cores saturate. Manufacturers often specify the current at which inductance drops by 20 or 30 percent. The converter does not model any of this. It changes the unit of the nominal number you enter, and tolerances and saturation behavior remain on the data sheet.
Converting in the other direction
To convert nanohenries to microhenries, swap the units on the page and enter the nanohenry value. A value of 220 nH gives 0.22 µH, and 4,700 nH gives 4.7 µH. The same factor applies in reverse as a division by 1,000. People sometimes confuse this with the conversion between nanohenries and picohenries, which has the same factor but is one step lower. Picohenry values appear in very high frequency designs, where even a short via adds a measurable share of a nanohenry. Because each step is a factor of 1,000, it is easy to apply the right step twice or not at all. Writing the chain down, for example 10 µH = 10,000 nH = 10,000,000 pH, prevents a missed step.
Common mistakes
The most common mistake is typing a value in the wrong unit and getting a plausible but incorrect result. A data sheet that lists 100 nH should not be entered as 100 µH. Another is confusing inductance with inductive reactance. The reactance of an inductor at frequency f is X = 2πfL in ohms, and it depends on frequency, while inductance is a property of the component. A 10 µH inductor has a reactance of about 62.8 Ω at 1 MHz. The converter works on inductance only. A third mistake is mixing inductance with mutual inductance or with the inductance per unit length of a cable, which is given in µH per meter or nH per meter. Those quantities need the length to produce a total, and this page does not take a length input.
Self-resonance and the usable range
A real inductor has parasitic capacitance between its windings, so above some frequency it stops behaving like an inductor. The self-resonant frequency is where the inductance resonates with that parasitic capacitance, and manufacturers list it on the data sheet. A 10 µH chip inductor may have a self-resonant frequency in the tens of megahertz, while a 47 nH RF part can reach into the gigahertz range. Using the part above its self-resonant frequency makes it behave as a capacitor. This matters for unit conversions because designers compare nanohenry-scale RF parts and microhenry-scale power parts in the same project. The numbers might look related, but the 10,000 nH power inductor is a different kind of component with a different usable band. The conversion gives equal values, and the data sheet tells you where each part works.
Series and parallel combinations
Inductors in series add when they do not share magnetic flux: 10 µH plus 4.7 µH gives 14.7 µH, or 14,700 nH. Adding a 15 nH trace to the 10 µH part makes 10,015 nH, which shows how small the trace is next to the inductor. In parallel, the combined value is the reciprocal of the sum of reciprocals, so two 10 µH inductors give 5 µH, or 5,000 nH. Working in one unit removes a common slip in which a nanohenry figure is added to a microhenry figure without scaling. The converter helps you place both values on the same scale before you add. Coupled inductors, such as the two windings on a common core, need mutual inductance to be included, and this page does not model that.
Scope and limits
The page expresses a known inductance in another unit and does not calculate installation limits, equipment ratings, protection, material response or compliance. It does not select a core material, estimate saturation current, check a design against an electromagnetic compatibility rule or decide whether a part is safe for a circuit. For a design, use the manufacturer's data sheet and a simulation or measurement. The SI Brochure from the BIPM and NIST Special Publication 811 describe the henry and the metric prefixes if you need an authoritative reference. Use this converter for quick, exact unit changes and keep track of the original unit in your notes so that a reviewer can follow the chain.