Conductance on adjacent scales

Transistor datasheets list transconductance in millisiemens, op-amp and sensor notes give small-signal values in microsiemens, and a resistor table reads in kilohms and megohms. Getting the three into one unit makes a design note easier to compare. This page multiplies the millisiemens value by 1,000 and returns microsiemens. The step is a plain prefix change: milli is 10^-3 and micro is 10^-6. Typical readers are electronics students working through small-signal exercises, hobbyists matching a part to a circuit, and technicians who read a multimeter or an LCR meter in one range and a datasheet in another. The page restates a conductance. It does not compute gain or bias.

Why the factor is 1,000

The siemens is defined as one ampere per volt, and the prefixes come from the BIPM SI Brochure. One millisiemens is 0.001 S and one microsiemens is 0.000001 S, so the ratio is 1,000 and µS = mS × 1,000. The multiplier is fixed by the prefixes, so a 2.5 mS reading stays a 2,500 µS reading to the same precision. Moving the decimal point three places to the right gives the result: 2.5 mS becomes 2,500 µS. The output is always larger than the input because the target unit is smaller. If your result is smaller than the input, the units in the menus are reversed, and the page is dividing instead of multiplying.

Ten millisiemens in microsiemens

The page opens with 10 mS and returns 10,000 µS. A conductance of 10 mS corresponds to a resistance of 100 ohms, and 10,000 µS to the same 100 ohms. The reciprocal check is quick: 10,000 µS is 0.01 S, and 1 divided by 0.01 S is 100 ohms. Equally, a 1 kΩ resistor has a conductance of 1 mS, or 1,000 µS, and a 100 kΩ resistor has 10 µS, which is 0.01 mS. Those pairs of resistance and conductance give you anchors to judge an input before you read the output. The default sits in the range of small power resistors and loads.

Resistors and their conductance

Taking reciprocals helps when resistors are in parallel. A 2.2 kΩ resistor has a conductance of 1 / 2,200 = 0.4545 mS, which is 454.5 µS. Adding a 10 kΩ resistor in parallel adds 0.1 mS, or 100 µS, to give 0.5545 mS, which is 554.5 µS and corresponds to about 1.803 kΩ. Working in conductance turns the parallel formula into a sum. The page converts each value between mS and µS, so a spreadsheet column can use one unit throughout, and the sum of 454.5 µS and 100 µS can be read in either unit without a second look at the arithmetic. Rounded results should keep as many digits as the resistor tolerance supports, and a 5 percent resistor does not justify more than two significant digits.

Transconductance in transistors

A bipolar transistor biased at 1 mA of collector current has a transconductance of about 1 mA divided by 25.9 mV at room temperature, which is about 38.6 mS, or 38,600 µS. MOSFET datasheets often list forward transconductance in the range of tens of millisiemens to several siemens for power parts, and in the range of hundreds of microsiemens to a few millisiemens for small signal parts. These figures are illustrative and depend on bias, temperature and device. A circuit designer who reads a value in mS from one sheet and in µS from another uses the page to line them up, and then reads the actual conditions from the datasheet tables and curves.

Water and sensors that read conductance

A conductivity probe measures conductance between two electrodes and multiplies by its cell constant to get conductivity, in µS/cm or mS/cm. The conductance itself, in mS or µS, is the raw quantity, and some lab setups log it directly before the constant is applied. A cell constant of 1 cm⁻¹ turns 1,413 µS of conductance into 1,413 µS/cm. This page converts the raw conductance only, and does not apply a cell constant. For the conductivity scale use the per-centimeter converters. A plausible reading depends on the cell, the temperature and the solution, so cross-check with a calibration standard. For example, a cell of constant 0.1 cm⁻¹ reading 141.3 µS corresponds to 14.13 µS/cm, while a cell of constant 10 cm⁻¹ reading the same conductance corresponds to 1,413 µS/cm, which shows why the cell is part of the measurement and not an afterthought.

From µS back to mS

To convert in the other direction, choose µS as the source and mS as the target. A value of 1 µS equals 0.001 mS, 10 µS equals 0.01 mS and 454.5 µS equals 0.4545 mS. Divide by 1,000. The smaller number in mS is easier to compare with other values in the same range, while the larger number in µS avoids leading zeros. Pick the unit that gives numbers between about 1 and 999, which is the convention that most datasheets follow, so 0.045 mS is better written as 45 µS and 12,000 µS as 12 mS. Switching units to keep the numbers readable is what prefixes are for, and the page does this at no cost in accuracy. Engineers also keep the engineering-notation habit of using exponents that are multiples of three, so 2,500 µS is written as 2.5 mS, and values such as 0.045 mS are rewritten as 45 µS.

Measurement limits and digits

Multimeters that measure conductance, typically in nanosiemens, and LCR meters give a few digits. The converted value should keep the digits of the measurement. Reporting 454.5 µS from a 0.4545 mS value implies a precision that a 5 percent resistor does not offer. The page keeps full precision internally and rounds only the displayed result. Lead resistance, contact resistance and temperature affect low-value measurements, and for tiny conductances leakage across a dirty board can dominate the reading. Record the instrument range and the conditions beside the number. Clean the board with isopropyl alcohol and let it dry before you repeat a leakage reading, because flux residue and moisture can raise the conductance by orders of magnitude and mislead a comparison between two boards.

What this page does not calculate

The converter rewrites a conductance in microsiemens and leaves the rest of the circuit to you. It does not compute gain, bias, power, noise or equivalent resistance of a network, and it does not check a part against its ratings. Use the datasheet and a circuit analysis for design decisions. The page also does not tell you whether a part suits an application, and a value that looks right in one unit can still be wrong for the circuit.