Conductance, not conductivity
These units measure electrical conductance, the reciprocal of resistance, in siemens. Conductivity, the property of a material measured per unit length, has its own units such as S/m and µS/cm. On this page the siemens stands alone, so a component or a measured path is being described, not a sample of material. Conductance is what a multimeter with a conductance range displays, what a data sheet gives for transistor transconductance, and what a cell test might return before it is multiplied by a cell constant. Treating these as separate quantities prevents a common mix-up, in which a µS conductance reading is typed into a µS/cm field. The prefix conversion on this page is simple: divide by 1,000 to go from µS to mS.
Where the default sits
The page starts with 10 µS, giving 0.01 mS. In resistance terms, 10 µS corresponds to 100 kilohms, since conductance in siemens is one divided by the resistance in ohms. A value of 1,000 µS equals 1 mS and 1,000 ohms, and 2,500 µS equals 2.5 mS and 400 ohms. Moving between µS and mS is a matter of reading the label, but the reciprocal shows quickly whether the number fits the component. A device whose conductance converts to a resistance far from the expected value points to a mistyped prefix or a damaged part.
Transconductance in transistor data sheets
Small-signal transistors and amplifier stages are described by transconductance, the change in output current for a change in input voltage, which is measured in siemens. Values in the data sheets of bipolar and field-effect devices are often listed in mS, while some precision parts use µS or even smaller. A bipolar transistor biased at 1 mA collector current has a transconductance of about 38 mS at room temperature, which is 38,000 µS. A conversion between the two prefixes helps when you compare a measured value from a curve tracer with a catalog figure. Always check the bias conditions stated beside the number, because transconductance changes with current and temperature. A MOSFET stage listed at 20 mS is 20,000 µS, and a small JFET at 4 mS is 4,000 µS. Audio and sensor preamplifier designers use these values to estimate gain, since a stage gain is roughly the transconductance times the load resistance, so a wrong prefix produces a gain that is off by a factor of 1,000 and a bias point that looks plausible on paper.
Conductance ranges on multimeters
Several bench multimeters offer a conductance range for very high resistances, displayed in nanosiemens, because measuring a high resistance by conductance extends the reading range. In the other direction, a conductance reading in the µS to mS range suits low to moderate resistances, such as a damp surface or a moderately leaky component. A meter that shows 450 µS is reading 0.45 mS, a resistance of about 2.2 kilohms. Knowing the prefix on the screen avoids reading a leaky board as an open circuit or the reverse. Relative mode is handy here: zero the meter with the leads open, then touch the test points, and the display shows only the added conductance of the part. Write the prefix next to each reading in your notes, because a reading of 450 without a unit could mean 450 µS, 450 mS or 450 nS on three different ranges. The same conversion appears in the manual tables that map ranges to resolution.
Cells, probes and the cell constant
A conductivity cell measures conductance between two electrodes, and the instrument multiplies it by the cell constant, in 1/cm, to obtain conductivity. A cell with a constant of 1.0 per cm and a conductance of 1,413 µS gives a conductivity of 1,413 µS/cm. A conductance of 2,500 µS equals 2.5 mS, and with a cell constant of 0.1 per cm the conductivity is 250 µS/cm. When you inspect a raw reading from a probe, convert the conductance to the prefix your formula uses before you apply the constant. That order keeps the units straight and gives the same result as converting at the end.
Water and filter sensors in practice
Some DIY and appliance sensors give a conductance rather than a conductivity because the geometry is fixed in the hardware. An aquarium controller or a coffee machine descaling sensor may output a value in µS or mS and compare it with a threshold. A threshold written as 0.5 mS and a reading logged as 480 µS are on the same scale, which is the same as 0.48 mS. Comparing in one prefix avoids false alarms. If you build a project with a microcontroller, keep the conversion in a single function so that the prefix is applied once and documented in the code.
Relation to resistance for quick estimates
Siemens and ohms are reciprocals, and the prefixes mirror each other: millisiemens correspond to kilohms and microsiemens to megohms. So 1 mS is 1 kilohm, 0.1 mS is 10 kilohms and 10 µS is 100 kilohms. For parallel paths the conductances add directly, which is why a conductance view is convenient: two leakage paths of 3 µS and 7 µS combine to 10 µS, or 0.01 mS. In series, resistances add instead. Choose the representation that makes your calculation additive, and convert with this page when a result needs a different prefix.
Hand checks
Divide by 1,000 to convert µS to mS, and multiply by 1,000 to go back. A value of 36 µS is 0.036 mS, and 7,200 µS is 7.2 mS. If the page returns a number that is a thousand times too large or too small, check that the menus are not reversed. When you write the result in a report, include the unit with every value and keep the number of significant figures in line with the precision of the instrument that produced it.
Conductance readings and component ratings
The page restates a conductance in another prefix. It does not calculate the resistance of a circuit, check a component against its rating, or judge whether a measurement is valid. The calculator does not evaluate installation limits, equipment ratings, protection or compliance. Conductance values also depend on temperature, frequency and applied voltage for many materials and components, so the number is meaningful only with the conditions under which it was taken.