cubic feet per minute (ft³/min): flow rate unit guide

ft³/min is the supported cubic-foot flow rate per minute.

Measurement basis

Its recorded m³/s factor is 0.0004719474432.

Definition conventions

US and imperial gallons differ. Barrels use the US petroleum definition of 42 US liquid gallons.

Conversion method

Multiply ft³/min by the stored compound factor. It includes both cubic-foot volume and the minute denominator.

Reference equivalent of ft³/min

1 ft³/min = approximately 0.0004719474432 m³/s.

Recorded scale factors: 0.0004719474432 for ft³/min; 1 for m³/s.

Worked example

Known input: 10 ft³/min. Reference equivalent: 0.004719474432 m³/s. The return conversion gives approximately 10 ft³/min.

The reference calculation keeps both components of the flow unit.

Common reference values

Input (ft³/min)Reference equivalent (m³/s)
10.0004719474432
50.002359737216
100.004719474432
250.01179868608
500.02359737216
1000.04719474432

Compare one ft³/min with other units

Target unitEquivalent of 1 ft³/minDefinition guide
cubic meters per second (m³/s)0.0004719474432Read definition
cubic meters per hour (m³/h)1.69901079552Read definition
liters per second (L/s)0.4719474432Read definition
liters per minute (L/min)28.316846592Read definition
liters per hour (L/h)1699.01079552Read definition
cubic feet per second (ft³/s)0.0166666666667Read definition
us gallons per minute (US gal/min)7.48051948052Read definition
uk gallons per minute (imp gal/min)6.22883545904Read definition

The airflow unit of American ventilation

Cubic feet per minute, written ft³/min or cfm, is the usual unit for airflow in heating, ventilation and air conditioning in the United States. Fans, ducts, range hoods, bathroom exhausts, computer coolers, dust collectors and vacuum cleaners are all rated this way. The unit says how many cubic feet of air pass a point each minute. Because a cubic foot is defined by the foot, which is exactly 0.3048 m, the SI relationship is also exact: 1 cfm is 0.3048³ / 60 = 0.0004719474432 m³/s. That is 0.4719474 L/s, 28.316847 L/min and 1.699011 m³/h. Metric countries quote the same fans in L/s or m³/h, so the factor is needed whenever American equipment is compared with European data sheets.

Conversions in daily use

A few conversions cover most work. Multiply cfm by 0.4719474 for liters per second, by 1.699011 for cubic meters per hour, and by 7.480519 for US gallons per minute if the substance were liquid. In the other direction, 1 L/s is 2.118880 cfm and 1 m³/h is 0.588578 cfm. A 300 cfm range hood moves 141.6 L/s or 509.7 m³/h. A 2,000 cfm rooftop fan moves 943.9 L/s. A computer fan rated at 60 cfm moves 28.3 L/s, or 101.9 m³/h. The fan figures are examples chosen for scale. Because the time unit is minutes, a flow in cfm and a flow in cubic feet per second differ by a factor of 60, a slip that is easy to make.

Room air changes from cfm

Ventilation is often judged by air changes per hour. For a room of volume V in cubic feet and an airflow in cfm, ACH equals cfm × 60 / V. A bedroom measuring 20 ft by 15 ft with an 8 ft ceiling is 2,400 ft³. A supply of 100 cfm gives 100 × 60 / 2,400 = 2.5 air changes per hour. Doubling the airflow doubles the rate. In metric terms the same room is 67.96 m³ and the airflow is 169.9 m³/h, which gives 169.9 / 67.96 = 2.5. The ratio does not depend on the unit system as long as volume and flow use the same length unit. Kitchens, laboratories and clean rooms have targets far above this residential example, and the codes that set them differ by region.

Sensible heat carried by moving air

Airflow in cfm links to heating and cooling power. For standard air, the sensible heat in BTU per hour equals about 1.08 × cfm × temperature difference in °F. Supplying 1,000 cfm at 20 °F warmer than the room delivers 1.08 × 1,000 × 20 = 21,600 BTU/h, which is 6.33 kW. The 1.08 comes from the density of air times its specific heat times 60 minutes per hour, and it is valid near sea level. At altitude the air is thinner, so the same cfm carries less heat, roughly 3 to 4 percent less for each 1,000 feet of elevation. In SI terms the same flow of 1,000 cfm is 0.472 m³/s, and the heat in watts is about 1.2 kg/m³ times 1,005 J/(kg·K) times 0.472 m³/s times a temperature difference of 11.1 K, which gives roughly 6.3 kW and agrees with the figure above. A commonly cited planning figure for residential cooling is somewhere around 350 to 400 cfm per ton of cooling, where one ton is 12,000 BTU/h. Treat these as rules of thumb, not as design values.

Standard cfm and actual cfm

A gas expands and contracts with temperature and pressure, so a cubic foot of air is not always the same amount of air. Fans move actual cubic feet, abbreviated acfm, at whatever the conditions are. Compressed-air equipment is often rated in scfm, standard cubic feet per minute, which refers to a reference temperature and pressure. Definitions of the reference vary by industry, with 14.7 psia and 68 °F or 60 °F being common, so two scfm figures can differ by a few percent. A compressor that delivers 20 scfm at 100 psi gauge delivers many more actual cfm when expanded to atmospheric pressure at its intake. When comparing machines, confirm that both figures use the same reference conditions before relying on the numbers.

Ventilation requirements in cfm

Building ventilation standards often state requirements as cfm per person plus cfm per square foot. ASHRAE Standard 62.1 gives rates for various spaces, and a commonly cited office value is about 5 cfm per person plus 0.06 cfm per square foot of floor area. For a 1,000 ft² office with 10 occupants, that works out to 5 × 10 + 0.06 × 1,000 = 110 cfm of outdoor air, which is 51.9 L/s. These rates are quoted from memory of the standard and may differ in the edition in force, so the current edition of the standard and local codes should be consulted for any real design, since they change between editions. The point of the example is the arithmetic: per-person and per-area terms are added and then converted to metric if needed.

Fan performance changes with resistance

A fan rating in cfm is measured at a certain static pressure, often zero or a stated value. As ductwork, filters and grilles add resistance, the delivered flow falls along the fan curve. A bathroom fan rated at 80 cfm at 0.1 inches of water may deliver less than 50 cfm through a long run of flex duct with several bends. Fan laws say that flow is proportional to fan speed, so a fan running at 80 percent speed delivers about 80 percent of the flow, while pressure falls with the square and power with the cube. These relations let you estimate the effect of a speed change but do not replace the manufacturer curve. When sizing, use the flow at the pressure the system will actually present.

Cfm, CFM and MCFM readings

Writing cfm in lowercase is standard in trade documents, with CFM in capitals also common, and the ISO-style form is ft³/min. The m in cfm is minutes, not meters or thousand, so check it against MCFM or MMCFM, which in natural gas mean thousand and million cubic feet per minute. Another slip is the cubic part: a volume factor needs the foot-to-meter ratio cubed, so applying 0.3048 once to a cubic foot would overstate the result by a factor of about 10.8. For an airflow, 0.3048 once gives 0.3048 m³/min where the correct value is 0.02832 m³/min. The same care applies to areas: a duct cross-section in square inches divides by 144 to reach square feet, not by 12. The figure 35.3147 cubic feet per cubic meter should be checked against 28.3168 liters per cubic foot. Finally, keep duct velocity separate: a velocity in feet per minute multiplied by a cross-section in square feet gives cfm.

Precision and checking

  • Keep measured flow precision.
  • Retain ft³/min on the source.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →