liters per second (L/s): flow rate unit guide

L/s expresses volumetric flow in liters each second.

Measurement basis

The supported factor is 0.001 m³/s per L/s.

Definition conventions

US and imperial gallons differ. Barrels use the US petroleum definition of 42 US liquid gallons.

Conversion method

Multiply L/s by 0.001 for the reference flow. The second denominator does not change.

Reference equivalent of L/s

1 L/s = approximately 0.001 m³/s.

Recorded scale factors: 0.001 for L/s; 1 for m³/s.

Worked example

Known input: 10 L/s. Reference equivalent: 0.01 m³/s. The return conversion gives approximately 10 L/s.

The reference result applies the liter volume definition.

Common reference values

Input (L/s)Reference equivalent (m³/s)
10.001
50.005
100.01
250.025
500.05
1000.1

Compare one L/s with other units

Target unitEquivalent of 1 L/sDefinition guide
cubic meters per second (m³/s)0.001Read definition
cubic meters per hour (m³/h)3.6Read definition
liters per minute (L/min)60Read definition
liters per hour (L/h)3600Read definition
cubic feet per second (ft³/s)0.0353146667215Read definition
cubic feet per minute (ft³/min)2.11888000329Read definition
us gallons per minute (US gal/min)15.8503231415Read definition
uk gallons per minute (imp gal/min)13.1981548979Read definition

The unit for pipes, pumps and pumping stations

Liters per second is the working flow unit for water supply, drainage and pump selection in many countries. It sits between the very small flows of L/min and the large flows of m³/s: 1 L/s = 0.001 m³/s = 3.6 m³/h = 60 L/min = 86.4 m³/day. A value in L/s is easy to scale to a day, since a steady 1 L/s moves 86,400 L, or 86.4 m³, in 24 hours. In US units 1 L/s = 15.8503 gal/min, because 60 / 3.785411784 = 15.8503. The Volumetric flow converter on the converters hub uses m³/h = m³/s × 3600 for the time base. Treatment plants, hydrants and well tests report flows in L/s because the numbers fall in the range of one to several hundred.

Pipe velocity from flow and diameter

The velocity in a full pipe is v = Q / A, with Q in m³/s and A in m². Take 10 L/s, which is 0.01 m³/s, through a pipe with an inside diameter of 100 mm. The area is π × 0.05² = 0.007854 m², and the velocity is 0.01 / 0.007854 = 1.273 m/s. The same 5 L/s in a 50 mm pipe has an area of 0.0019635 m² and a velocity of 2.546 m/s, twice as fast for half the flow, because the area falls to a quarter when the diameter is halved. Guidance for water mains often aims for velocities near 1 to 2 m/s, though the preferred range depends on the pipe material and the application. Higher velocities raise friction loss and the risk of pressure surges when valves close.

Filling a pool at a stated rate

The flow unit connects directly to the time it takes to fill a known volume. A pool 50 m long, 25 m wide and 2 m deep holds 2,500 m³, which is 2,500,000 L. Filled at 50 L/s, it takes 2,500,000 / 50 = 50,000 s, or 13.9 hours. Pool fill rates are often limited by the supply connection, so the same job on a 25 L/s line needs 27.8 hours. A garden hose that delivers 0.3 L/s would need 8,333,333 s, which is 96 days, to do the same job. A household tub of 150 L fills from a 0.2 L/s tap in 750 s, or 12.5 minutes. These calculations assume a steady flow, and real supply pressure usually drops when demand is high. A time to fill is volume divided by flow, so the units must cancel: liters over liters per second gives seconds.

Fire pumps and hydrant flows

Fire service pumps are rated in L/min in many countries, and a pump delivering 2,000 L/min moves 33.3 L/s. In the US, hydrant flow tests are in gallons per minute, and a hydrant flowing 1,000 gpm discharges 63.09 L/s, since 1,000 × 3.785411784 / 60 = 63.09. A hose line with a fog nozzle might deliver around 400 to 500 L/min, or 6.7 to 8.3 L/s, and a master stream monitor several times that. These flows are what the supply has to sustain, and design standards for sprinklers and hydrants give required flows and durations. Matching a requirement stated in gpm to a supply capacity in L/s starts with the factor of 0.0630902 L/s per gpm, which is the reciprocal of 15.8503.

Per-person demand and what a town draws

Municipal planning converts a population to a flow. An illustrative demand of 150 L per person per day for 10,000 people is 1,500,000 L/day, which is 1,500,000 / 86,400 = 17.4 L/s on average. Peak demand within a day is higher, often by a factor of two or more, so a system sized for the average would fall short in the morning peak. Leakage and industrial use add to the figure. The conversion from L/day to L/s divides by 86,400, and the reverse multiplies. A treatment plant rated 200 L/s treats 17,280 m³ per day. These are illustrative numbers, and actual per-capita demand differs widely between regions, seasons and housing types.

Hydraulic power from flow and head

A pump lifting water does work at a rate of ρ × g × Q × H, with density in kg/m³, g = 9.80665 m/s², flow in m³/s and head in meters. A flow of 10 L/s lifted 20 m gives 1,000 × 9.80665 × 0.01 × 20 = 1,961 W, or 1.96 kW of hydraulic power. The motor must supply more, since pumps are not perfectly efficient: at 60 percent efficiency, the shaft power is 3.27 kW. The relation shows why flow in L/s enters power calculations, and why a doubled flow at the same head doubles the power. A flow converted to m³/s first avoids a factor-of-1,000 error. A head loss in the pipes adds to the lift, so the real head is more than the geometric height.

Rivers, cumecs and small streams

Hydrologists measure river discharge in m³/s, nicknamed cumecs, and 1 m³/s equals 1,000 L/s. A small stream carrying 50 L/s discharges 0.05 m³/s, or 4,320 m³ per day. A large river carries thousands of m³/s, which would be millions of L/s, and the unit changes for that reason. Springs and small streams fit L/s well, and water rights or abstraction licenses may be written in L/s, with limits tied to a season. Low-flow measurements use a weir or a bucket and stopwatch: a 10 L bucket that fills in 8 seconds shows 1.25 L/s. The time resolution of the measurement limits the accuracy of such a figure, so a count of the fill time over several trials gives a better average. A weir or flume is used for larger streams, and the result is converted from m³/s to L/s by multiplying by 1,000.

Reading L/s, l/s, lps and the volume-rate difference

The symbol is L/s, with the capital L for liter. The forms l/s, lps and LPS appear in drawings and tender documents. A liter by itself is a volume, and L/s is a rate, so a tank of 500 L is not a flow of 500 L/s. The conversions in this guide hold for volumetric flow in any liquid, and they do not convert to a mass flow without a density. A time unit is a part of the symbol, and dropping it from a record leaves a number that cannot be checked. A design flow of 12 L/s should therefore be recorded together with its basis, such as peak, average or fire-flow, since the same site can have several flows in L/s that serve different purposes.

Precision and checking

  • Keep source flow precision.
  • Retain L/s rather than L alone.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →