Air pumps and small gas flows quoted per hour
Liters per hour is the unit on many aquarium air pumps, pond aerators, hydroponic supplies and small gas flow meters. US vendors, on the other hand, rate blowers and pumps in cubic feet per minute. A buyer comparing a 5,000 L/h pond aerator with a US model rated in CFM, or a student converting a laboratory gas flow, needs the two on a common scale. This page does the conversion. The result is a volume of air, water or other fluid passing each hour, so one step in understanding capacity. Whether the pump can reach that flow against a given depth or backpressure is a separate question that the rating tables answer.
The arithmetic behind 1,699.01
One liter is exactly one cubic decimeter, which is 0.001 m³. A cubic foot is 0.028316846592 m³, so it contains 28.316846592 liters exactly. One CFM then moves 28.316846592 liters each minute, and 60 minutes make an hour, giving 28.316846592 × 60 = 1,699.01079552 L/h. The page uses L/h = ft³/min × 1,699.01079552. The reverse factor is 0.00058857778 CFM per L/h. The foot comes from NIST SP 811, and the liter is accepted for use with the SI by the BIPM. Both are defined values, so the factor carries no measurement uncertainty.
The default and typical values
The default of 10 CFM gives 16,990.1080 L/h. Smaller entries are closer to what aquarium and laboratory equipment delivers. A flow of 0.5 CFM gives 849.5054 L/h, 2 CFM gives 3,398.0216 L/h and 25 CFM gives 42,475.2699 L/h. Running the other way, a 1,000 L/h air pump delivers 0.5886 CFM, and a 5,000 L/h pond pump delivers about 2.9429 CFM. If the numbers feel inflated compared with the CFM figure you started from, remember that an hour holds 60 minutes and a liter is a small volume, so L/h values always look large. Another use is a drip system that supplies 4 L/h per emitter. A hundred emitters need 400 L/h, which is only 0.2354 CFM of water, a figure that shows how modest irrigation flows are next to ventilation flows.
Comparing rated air pumps
Suppose one pond aerator lists 3,600 L/h and another lists 2.5 CFM. Converting the second gives 4,247.5 L/h, which is about 18 percent more than the first. Without conversion, the numbers 3,600 and 2.5 hide the difference. Remember that manufacturers measure these ratings under particular conditions, often with no water depth, and real output falls as the air stone sits deeper. Treat the converted number as the label comparison, not the delivered flow at your depth. A hydroponic grower sizing air for several reservoirs can add the converted L/h values of each pump to see the total volume of air supplied per hour, and then compare it with the number of air stones in the system. Dividing the total by the number of stones gives the average flow each one receives, though real distribution is uneven when the tubing runs have different lengths. Comparing two labels at the same conditions is a fair use of the page.
Liters per hour is also a water unit
Hourly liter figures are common for water too, such as drip irrigation emitters, small dosing pumps and reverse osmosis units. For water, a flow expressed in CFM is unusual, but the conversion still holds. A pump delivering 0.1 CFM of water moves 2.83 liters per minute, or 169.9 L/h. The converter treats volume only, so it applies to air and water alike. If you need mass, you must multiply by density, which is about 1 kg per liter for water but close to 1.2 g per liter for air under ordinary room conditions. The conversion itself is the same for both.
Reading the digits
The long decimal factor produces results with many digits, such as 16,990.107955199997 from floating-point arithmetic. The tail digits are noise from binary representation and carry no meaning. Rounding to three or four significant figures, 16,990 L/h, matches the accuracy of any fan rating. In the reverse direction, 300 L/h becomes 0.17657 CFM, and a result like that has more digits than the source number supports. State only as many digits as the weakest input has. When the conversion feeds a purchasing decision, a result such as 3,398 L/h is precise enough to compare against a rating of 3,400 L/h, and the small gap of 0.06 percent is well inside any manufacturing tolerance. A bench tester that reads in CFM can also be compared with a metric specification this way, as long as both refer to the same test condition.
Mistakes between L/h, L/min and m³/h
Three hourly or per-minute metric units can be confused. A flow in L/h has a number sixty times larger than the same flow in L/min, and a number one thousand times larger than the same flow in m³/h. So 16,990 L/h is 283.17 L/min and 16.99 m³/h. A catalog that mixes L/min for one product and L/h for another invites errors, and only careful reading of the unit prevents them. The From and To menus offer all of them, so use the page to line the numbers up before you compare.
Units for gas flow and standard conditions
Gas flow in liters per hour is often given at standard or normal conditions, written as nL/h or sL/h, and then it refers to a specified temperature and pressure. A cubic foot per minute from a US vendor may be at actual or standard conditions as well. The page does no correction, so convert only figures that state the same reference conditions. If one figure is at standard conditions and the other is at actual conditions, an additional gas-law calculation is needed before the two can be compared in any meaningful way.
What a pump label leaves out
The page changes the unit of a flow rate. It does not choose a pump, estimate the flow at a particular depth or pressure, check dosing accuracy, or assess any safety limit. Real output depends on backpressure, supply voltage, air stone resistance, tubing and wear. Read the manufacturer curve for those effects and use this page only to make the labels comparable. If a seller lists the output only in liters per hour and another only in cubic feet per minute, convert one of them and confirm the unit on the data sheet before you buy.