Pump ratings against blower ratings

Small air pumps, gas samplers and vacuum devices are often rated in liters per hour, especially in European catalogs. Fans, blowers, compressors and range hoods in the United States are rated in cubic feet per minute, written CFM. Anyone who matches a pump to a duct, compares an aquarium air pump with a fan rating or reads a lab device against a ventilation spec has to bridge the two. This page converts L/h to CFM directly. The result is a volume flow rate at the conditions where the volume was measured, so it works for air, gases and liquids alike, though CFM is used almost only for gases and air. Catalogs from different regions also differ in whether a flow rating applies at free air or at a stated back pressure, so check the footnote before you set two ratings side by side.

The factor and its parts

A cubic foot is 0.3048³ = 0.028316846592 m³, which is 28.316846592 L. An hour has 60 minutes. One L/h is therefore 1 / (60 × 28.316846592) = 0.000588577778691 CFM. One CFM is 28.3168 L/min or 1,699.01 L/h. The default of 10 L/h converts to 0.00588578 CFM. The numbers are small because a cubic foot per minute is a large flow compared with a liter per hour, so results for ordinary pumps are decimals. Both unit definitions are in NIST Special Publication 811, which keeps the conversion free of measured constants.

Aquarium air pumps

Aquarium air pumps are commonly listed in L/h, with small models rated near 100 to 600 L/h. A 200 L/h pump moves 0.1177 CFM, a 600 L/h pump moves 0.3531 CFM, and a 1,000 L/h pump moves 0.5886 CFM. These figures are free-air ratings, and the real flow at the airstone is lower because the water column adds back pressure. When comparing two pumps, use ratings measured at the same depth. The CFM figure lets you set a pump beside a small blower from a US catalog without doing the unit chain by hand. A 300 L/h pump feeding two airstones splits its 0.1766 CFM between them, so each stone sees about half. Spreading the flow across more stones produces finer bubbles but less flow through each, and the CFM figure helps you judge how thin that split becomes.

Shielding gas and small gas supplies

Welders set shielding gas flow in cubic feet per hour on a US regulator, and a typical setting is around 20 CFH. That is 566.3 L/h, or 0.3333 CFM. A European regulator for the same job shows liters per minute, about 9.4 L/min. If a gas supplier lists a flow in L/h, converting to CFM and multiplying by 60 gives CFH for the regulator. The figure also tells you how long a cylinder will last, since the content of the cylinder in cubic feet divided by the CFH gives hours of use. An 80 cubic foot cylinder at 20 CFH, for example, lasts about four hours of continuous welding, and at 30 CFH it lasts under three. Because the flow is quoted per hour on the regulator and per minute in this page, keep the two time bases straight when you move between them.

Ventilation, fans and range hoods

Ventilation ratings are in CFM in the United States. A bathroom fan of 80 CFM moves 135,921 L/h, and a range hood of 300 CFM moves 509,703 L/h. These are in a different class from lab pumps, and the comparison is useful in one direction: it shows how much larger a ventilation flow is than a pump flow. A 600 L/h sampling pump, 0.353 CFM, takes less than half a percent of the flow of an 80 CFM fan. Sizing a sampling line or a makeup air supply starts from such ratios. Fans also lose flow as duct resistance rises, so the CFM printed on the box is the best case at low resistance, and the flow in a long, bent duct is lower. Check the fan curve for the resistance of your duct before comparing it with a pump.

Compressors and the meaning of standard CFM

Air compressor ratings use SCFM, standard cubic feet per minute, which refers to air at stated reference conditions, and a plain CFM figure refers to the actual conditions at the inlet. A small compressor rated 5 CFM delivers 8,495 L/h at those conditions. This page converts volume flow and does not correct for pressure or temperature. If your source gives standard flow in normal liters, the reference conditions of the two systems may differ, so confirm them before you rely on a conversion for sizing a tool or a regulator.

US fan and compressor specs in liters

To convert CFM to liters per hour, select cubic feet per minute as the source. One CFM gives 1,699.01 L/h, 5 CFM gives 8,495.05 L/h and 80 CFM gives 135,920.86 L/h. This direction suits a US fan or compressor spec read by someone working in liters. A rule of thumb is to multiply CFM by 1,700 for L/h or by 28.3 for L/min. The result has as many significant figures as the CFM rating, which is often only two or three. A small vacuum pump rated at 3 CFM moves 5,097 L/h, and a pump rated at 0.5 CFM moves 849.5 L/h. Vacuum pump ratings usually refer to free-air displacement, which falls as the pump pulls down toward its ultimate pressure, so the number is a ceiling for the flow you see in use.

Why the answers are so small

Many results on this page are less than one CFM. That reflects the scale of the units, not an error. A cubic foot is 28.3 L, and a minute is 60 times an hour, so 1,699 L/h is needed to reach 1 CFM. For tiny flows such as 10 L/h, the converter prints digits like 0.00588578. If you need a friendlier number, convert to liters per minute or cubic centimeters per minute instead. The value shown here keeps full precision for use in a calculation. As a reference point, 600 L/h is 10 L/min and 0.353 CFM, and 1,699 L/h is 28.3 L/min and exactly one CFM, so a pump near 1,700 L/h is where the CFM number reaches one.

Air density and fan ratings

This page converts a volume flow between units. It does not correct a gas flow for temperature, pressure or humidity, and it does not size any pump, fan or duct. Air density changes with altitude and temperature, so a fan that moves 80 CFM at sea level moves less mass at altitude. Use the manufacturer curve for any design decision.