Nameplates and single-line diagrams use both units

Electrical drawings label equipment with whichever unit gives a short number. A distribution transformer is marked 11 kV on the primary and 400 V on the secondary, and a motor nameplate may show 6.6 kV. A technician who works from those drawings has to compare the two sides in one unit, particularly when calculating a turns ratio or checking a meter range. This page converts a kilovolt value to volts by multiplying by 1,000. It is the commonest voltage conversion in practice, and it is the basis for transformer ratios, cable ratings and test voltage discussions at every scale from workshop to substation.

The volt and the factor of 1,000

The volt is the SI unit of electric potential difference, defined as one watt per ampere, and named after Alessandro Volta. The kilo prefix means 1,000, as given in the SI Brochure of the BIPM and in NIST SP 811. The formula is V = kV × 1,000, so 0.4 kV is 400 V, 6.6 kV is 6,600 V, and 13.8 kV is 13,800 V. The relation is exact and involves no measured constant. A fast check is that the volt is the smaller unit, so the number must grow. The symbol is a capital V, and kV is written with a lowercase k and a capital V. A space between number and unit follows the SI style.

The default of 10 kV

The default input of 10 kV returns 10,000 V. That figure is in the range of medium-voltage equipment, such as industrial feeders and the primary windings of pad-mounted transformers in some systems. It is also a test level for cable and switchgear withstand checks, though the required level depends on the equipment standard. The same voltage across a 1 mm air gap would be beyond the strength of air, which is why such equipment is built with solid, oil or gas insulation and generous clearances. The default is a plain round number for checking the arithmetic, and the page works equally with decimals such as 0.69 kV or 33 kV.

Utility voltage classes

Distribution and subtransmission networks use a set of standard levels that vary by country. Common values include 0.4 kV (400 V) for low-voltage three-phase supply in many IEC countries, 6.6 kV for industrial motors, 11 kV and 13.8 kV for distribution, and 33 kV for subtransmission. The page converts these to 400 V, 6,600 V, 11,000 V, 13,800 V and 33,000 V. Note that these are usually line-to-line values in three-phase systems. The voltage from one phase to ground is smaller by a factor of the square root of three, so an 11 kV system has about 6.35 kV, or 6,350 V, from each phase to ground.

Railway electrification

Electric railways use a small number of standard supply systems. A 25 kV, 50 Hz AC system is common on high-speed and main lines in Europe, Asia and elsewhere, and 25 kV is 25,000 V at the overhead wire. DC systems use 1.5 kV and 3 kV, which are 1,500 V and 3,000 V. A locomotive or train set takes its power from the wire through a pantograph and a transformer or converter, and its nameplate lists the supply voltages it accepts, sometimes in volts and sometimes in kilovolts. Multi-system trains that cross borders may list several, such as 1,500 V DC, 3,000 V DC and 25,000 V AC, and a reader comparing a nameplate in volts with a network map in kilovolts needs the conversion on this page to confirm that they match. The overhead wire voltage varies with load and distance from the substation, so the nominal value is a label, not a constant.

Spark ignition, neon signs and microwaves

Everyday equipment also operates at kilovolt levels. An automotive ignition coil delivers an open-circuit secondary voltage in the range of 20 to 40 kV, which is 20,000 to 40,000 V, to jump the spark plug gap. A neon sign transformer is often rated 15 kV, which is 15,000 V. The magnetron supply of a typical microwave oven uses a transformer secondary of about 2 kV, which is 2,000 V. In each case the current is small, but the voltage level means that the covers and insulation matter. Repairs on such equipment belong to qualified people following service instructions, and this page only supports the arithmetic.

Static shocks in volts

Static electricity gives another everyday reference. People generally begin to feel an electrostatic discharge at around 3 kV, which is 3,000 V, and walking across a carpet in dry air can charge a body to 10 kV or more. A discharge at 10 kV is 10,000 V. The energy in such a spark is very small because the body capacitance is only about 100 picofarads, so the shock is brief even though the voltage is high. Electronics manufacturing treats those voltages seriously, because sensitive devices can be damaged by discharges far below the level a person feels.

Line-to-line against phase-to-ground

The most common error is not the arithmetic but the meaning of the number. In a three-phase system, nominal voltage usually refers to the line-to-line value. An 11 kV system has 11,000 V between two phases and about 6,351 V between a phase and ground. A 400 V low-voltage system has about 231 V per phase, in line with the 230 V standard single-phase supply. Before converting a kilovolt figure, check which voltage it is. The page converts the number you type and does not know which definition it represents.

Nominal, maximum and test voltages differ

The page changes kilovolts to volts. It does not decide whether equipment is suitable for a voltage, specify clearances, check insulation, or determine compliance with an electrical code. Nominal, maximum and test voltages differ, and each appears on the equipment documentation. The factor of 1,000 is exact, so the accuracy of the output follows the number you enter. Any work on energized equipment should follow the manufacturer's instructions, the applicable code and your employer's safety rules. When a report lists a withstand test at 28 kV for a 13.8 kV class device, converting both to volts, 28,000 V and 13,800 V, makes the ratio of about 2.03 easy to see, and a reader can judge at a glance whether a quoted test figure is plausible for the class. Keep the unit with each number in tables.