Nanovoltmeters and quiet amplifier datasheets
Instruments built for very small voltages display nanovolts, and the best low-noise amplifiers list their input noise in nanovolts per square root of hertz. Some specifications, especially for offset drift, noise integrated over a narrow band or the resolution of a very sensitive meter, are given in picovolts. A person comparing two parts, or checking whether a meter can see a thermal voltage from a joint in a test fixture, needs both on the same prefix. This page multiplies a picovolt value by 0.001 and returns nanovolts. The shift is three places, and the tool prevents a slip when the numbers are moved between a datasheet and a noise budget.
One thousand picovolts per nanovolt
Pico is 10^-12 and nano is 10^-9, so one nanovolt equals 1,000 picovolts. The formula is nV = pV × 0.001, and the factor is exact because both prefixes are fixed powers of ten in the SI Brochure. A voltage of 250 pV is 0.25 nV, 4,000 pV is 4 nV, and 1,000,000 pV is 1,000 nV, which is also 1 µV. The volt is one joule per coulomb. By hand, move the decimal point three places to the left. Because the step is small, a sanity check is simple: the result must be a thousand times smaller than the input, and if it is larger the units are in the wrong order.
Ten picovolts in nanovolts
The default input of 10 pV returns 0.01 nV. That is a hundredth of the resolution of a good nanovoltmeter, which displays a single nanovolt on its lowest range. A figure that small is below the thermal noise of any real source in a normal bandwidth, so picovolt-level measurements rely on narrow bandwidth, long averaging and cooled or superconducting parts. Seeing the number in nanovolts makes the gap plain: a meter that resolves 1 nV, or 1,000 pV, cannot show 10 pV even in principle. If the page returns something larger than your input, the unit pair was reversed, since the nanovolt is the larger unit.
Resistor noise in nanovolts per root hertz
The thermal noise of a resistor is given by the square root of four times Boltzmann constant, temperature, resistance and bandwidth. At room temperature, a 1 kΩ resistor has about 4.07 nV per square root of hertz, and a 10 kΩ resistor about 12.9 nV per square root of hertz. Over a bandwidth of 10 kHz, the 1 kΩ value becomes about 407 nV, which is 407,000 pV. These numbers set a floor for any measurement made through that resistance. If a datasheet quotes the amplifier noise in pV per root hertz and the resistor noise in nV, convert to one unit before you decide which of them dominates.
Low-noise amplifiers and how they are specified
The quietest operational amplifiers specify an input voltage noise density of around 1 nV per square root of hertz, which equals 1,000 pV per square root of hertz. That figure covers the white-noise region. At low frequencies, the noise rises with a 1/f slope, and datasheets give a peak-to-peak value in a band such as 0.1 Hz to 10 Hz, often in tens of nanovolts. A part with 50 nV peak-to-peak noise in that band has 50,000 pV. The conversion helps when one vendor quotes picovolts and another nanovolts, and it keeps comparisons honest. The page does not integrate noise over a bandwidth or model a circuit. For a rough estimate, multiply a flat density by the square root of the bandwidth, so 1 nV per root hertz over 100 Hz gives about 10 nV rms, or 10,000 pV.
Thermal EMFs in a measurement setup
Low-level voltage measurements are disturbed by thermoelectric voltages at every junction of dissimilar metals. Copper-to-copper connections may produce only a fraction of a microvolt per degree, while ordinary solder and some terminals give a few microvolts. A thermal EMF of 0.2 µV is 200 nV and 200,000 pV, far above the noise of a good nanovoltmeter. This is why low-level setups use clean copper connections, keep junctions at one temperature and wait for thermal equilibrium. Writing a thermal EMF and an instrument resolution in nanovolts shows at a glance whether the setup can produce a trustworthy reading. Twisting the lead pair and keeping it out of drafts helps both ends stay at one temperature, which removes much of the thermal voltage before any conversion is needed.
Going from nanovolts to picovolts
To convert in the other direction, choose nanovolts as the source and picovolts as the target. One nanovolt is 1,000 pV, 4 nV is 4,000 pV, and 407 nV is 407,000 pV. Datasheets that list a bias or offset in nV and a noise floor in pV need this step before the two can be added in quadrature or compared. As a check, the result of any conversion in this direction ends in at least three more digits than the input. A value of 0.25 nV gives 250 pV, and a value of 12.9 nV gives 12,900 pV, which shows how the decimal point simply moves.
Reading symbols without mistakes
The symbol nV has a lowercase n and a capital V, and pV has a lowercase p. Capital NV or PV would not be valid unit symbols, and lowercase pv may be read as present value in a finance sheet. In a table that mixes noise densities, remember that nV/√Hz is a density and nV is a voltage, which are not the same thing and cannot be compared without a bandwidth. Spell out units in headers, keep one unit per column and note whether each figure is rms or peak-to-peak. A converted density stays a density, so the per root hertz part is carried along unchanged.
Reading a nanovolt figure with care
The conversion tells you nothing about the quality of a measurement. Bandwidth, source resistance, temperature, shielding and instrument calibration all determine whether a nanovolt-scale reading means anything. The page also does not decide whether a part is suitable for a given application. The factor is exact, so a surprising result almost always traces to a typed exponent or a selection of the wrong unit. Compare it with the anchor case, 1 nV returning 1,000 pV, and read the units on the source before looking for another cause. When you share a result, state whether it is a density, an rms value or a peak-to-peak value, because the same number means different things in each case.