Digits below the nanovolt

Precision voltage instruments show more digits than the range name suggests. A lock-in amplifier with a full-scale range of a few nanovolts reports readings whose last places fall at the picovolt level, and a low-noise preamplifier with a spectral density near 1 nV per root hertz produces, over a narrow band, rms noise of just a few nanovolts, which is thousands of picovolts. Researchers and technicians who work with such instruments move between the two units when they compare settings, noise estimates and results. This page multiplies the nanovolt value by 1,000 and returns picovolts. It is a quick check for lab notebooks and for coursework in measurement and instrumentation.

2.5 nV as 2,500 pV and 0.047 nV as 47 pV

Nano is 10^-9 and pico is 10^-12, so a nanovolt holds 1,000 picovolts. The page applies pV = nV × 1,000, using the prefix definitions in the BIPM SI Brochure and NIST SP 811, with no rounding. By hand, move the decimal point three places to the right: 2.5 nV becomes 2,500 pV and 0.047 nV becomes 47 pV. In the other direction divide by 1,000, so 750 pV is 0.75 nV and 4,200 pV is 4.2 nV. If your answer is smaller than the input when converting from nano to pico, the units are set backward. The step is small enough to do mentally, and the page is mostly useful for confirming a number copied from an instrument display. It also helps when two documents use different units for the same quantity, for example a noise table in picovolts and a front-panel display in nanovolts.

Ten nanovolts as ten thousand picovolts

The default input of 10 nV gives 10,000 pV. A 0.5 nV reading is 500 pV, and a 100 nV level is 100,000 pV. Large picovolt numbers can look alarming in a report, and scientific notation helps: 10,000 pV is 1 × 10^4 pV. The unit is chosen to keep the value readable, so most authors stay in nanovolts until a reading drops below 1 nV, and then they switch. A table that mixes nanovolts and picovolts in one column is harder to scan, so convert the whole column with the page and label the header with the unit. Keep the original values in a second column if a reviewer might want to check the conversion.

Resistor noise in picovolts

Every resistor produces thermal noise. At room temperature a 1 kilohm resistor has a noise density of about 4 nV per root hertz. Over a 100 Hz bandwidth that is 4 nV × 10, or about 40 nV rms, which is 40,000 pV. Over 1 Hz it would be only 4 nV, or 4,000 pV. A designer who wants the amplifier noise to be small compared with the source noise puts the numbers in one unit and compares them. Because the noise grows with the square root of the bandwidth and of the resistance, a narrower filter or a smaller resistor lowers it. The page converts a given figure and does not derive the noise itself.

Averaging toward smaller signals

Averaging many readings reduces random noise by the square root of the number of samples. Averaging 100 readings of a source with 40 nV of noise leaves about 4 nV, which is 4,000 pV, and averaging 10,000 readings gets to 0.4 nV, or 400 pV. That works only if the noise is random and the offsets stay stable, since averaging does not remove drift or a fixed offset. Experimenters who chase picovolt-level changes therefore stabilize temperature, use shielding and alternate the polarity of the measurement. Quoting the target in picovolts and the single-reading noise in nanovolts is common, and this page puts both on the same scale.

Data sheets and display digits

A meter may display a reading with a resolution in picovolts while its accuracy is far larger. If a nanovoltmeter shows 12.345 nV on a range with an accuracy of a few tenths of a nanovolt, the last digits are not meaningful. When you convert such a figure to 12,345 pV, the number of digits grows, and so does the temptation to quote all of them. Use the stated accuracy to decide how many to keep. In the example, 12.3 nV, or 12,300 pV, is a fair way to write it. Keep the long form in the raw data and round only in the summary.

Mains pickup against a picovolt signal

Cables act as antennas for the 50 or 60 Hz field of nearby wiring. A pickup of 0.2 µV, which is 200 nV or 200,000 pV, can appear on an unshielded lead without anyone noticing. Against a wanted signal of 10 pV it is 20,000 times larger. Lock-in amplifiers deal with this by measuring only at a chosen reference frequency, and good practice adds twisted, shielded cable, a single grounding point and a stable position for the leads, since a cable that moves can generate its own small voltage. Expressing the pickup in picovolts shows the size of the problem in the same units as the signal. If the pickup shrinks to a few picovolts after shielding, the arrangement is working.

Related units on either side

Next to the nanovolt are the microvolt, at 1,000 nV, and the picovolt, at one thousandth of a nanovolt. A signal of 0.003 µV is 3 nV, which is 3,000 pV. Going through the middle unit is a reliable check: nanovolts to microvolts is a division by 1,000, and microvolts to picovolts is a multiplication by 1,000,000. This page also lists volts, millivolts, kilovolts and megavolts, so one tool covers the full set when you need to relate a picovolt figure to the supply voltage of the circuit. For instance, a 3.3 V supply is 3,300,000,000 nV. The gap shows why shielding and layout matter in this work.

Noise floor and source resistance behind a picovolt figure

Whether a picovolt-level number can be measured with your instrument, whether it lies below the noise floor and what bandwidth and source resistance the reading assumed are questions a unit cannot answer. At this level two instruments can disagree on the same source, so use the manufacturer documents to decide what the numbers mean and record the conditions with every reading. When you write up results, give the unit with the number and keep the same unit through a table. A reader should be able to tell from the header alone whether a column holds nanovolts or picovolts.