The extremes of the voltage scale
Nanovolts are the realm of the most sensitive voltage measurements: thermocouple signals read to a fraction of a degree, strain gauge bridges, bioelectric amplifiers and the noise of a resistor. Kilovolts are the realm of power distribution, X-ray tubes, particle accelerators and insulation tests. A page that converts between them is something of an exercise in scale, and its use is mostly educational: to see how many orders of magnitude electrical engineering spans and to check the exponent handling in a calculation. The volt is the SI unit of electric potential difference, equal to one watt per ampere. The converter changes the prefix and leaves the quantity untouched. It does not tell you anything about equipment ratings, insulation, safe working distances or any limit that applies to a real installation.
The factor and the default result
Nano is 10^-9 and kilo is 10^3, so one nanovolt is 10^-12 kV. The formula is kV = nV × 10^-12. With the default 10 nV the result is 10^-11 kV. The decimal form is 0.00000000001, eleven places after the point, and the converter may display it as 1e-11, or as 1.0000000000000001e-11, where the last digit is an artifact of binary floating-point storage. The factor is exact because both prefixes are powers of ten in the SI, and NIST Special Publication 811 lists them. Going the other way, one kilovolt is 10^12 nV, which is a 1 followed by twelve zeros, or 1,000,000,000,000. A value like 750 nV converts to 7.5 × 10^-10 kV. A 33 kV line is 3.3 × 10^13 nV.
How the volt is realized
Since the 2019 revision of the SI, the volt is derived from fixed values of the Planck constant and the elementary charge. In practice, national metrology institutes realize it using the Josephson effect, in which an array of superconducting junctions driven by microwaves produces voltages that depend only on frequency and fundamental constants. The Josephson constant, 2e divided by h, is about 483,597.8 GHz per volt. This allows voltage standards to be compared with great accuracy, from microvolts to 10 V. Nanovoltmeters, which resolve a few nanovolts, are calibrated against such standards in a chain. These are descriptions of the measurement infrastructure, given to put the unit in context. The converter relies on the prefix definitions only and is unconnected with how any particular voltage is measured.
Thermal voltages and the nanovolt range
Thermocouples and thermal effects in circuits produce voltages in the microvolt and nanovolt range. A type K thermocouple gives roughly 41 µV per degree Celsius near room temperature, so a temperature change of 0.01 °C corresponds to about 410 nV. Unwanted thermoelectric voltages at junctions between different metals in test leads and connectors are typically a fraction of a microvolt per degree, enough to disturb measurements at the nanovolt level. That is why low-level measurements use copper connections, keep junctions at the same temperature and reverse the current to cancel offsets. A reading of 410 nV is 4.1 × 10^-10 kV. The numbers are typical orders of magnitude and not data for a specific instrument. They show the reason why nanovolt resolution matters in thermometry and in precision resistance measurement.
Resistor noise as a worked example
Every resistor produces thermal noise, known as Johnson noise, with a root-mean-square voltage equal to the square root of 4 times Boltzmann's constant times the temperature times the resistance times the bandwidth. For a 1 kilohm resistor at 300 K over a bandwidth of 1 kHz, the value is the square root of 4 × 1.380649 × 10^-23 × 300 × 1,000 × 1,000, about 1.29 × 10^-7 V. That is roughly 129 nV, or 1.29 × 10^-10 kV. Increasing the resistance to 100 kilohms multiplies the noise by the square root of 100, which is 10, giving about 1,290 nV. The example is a textbook relation and is illustrative of the scale of nanovolts in analog design. Real circuits add amplifier noise, flicker noise and pickup, which the page does not model.
Kilovolts in power and high-voltage work
Distribution networks commonly run at voltages from about 11 kV to 33 kV, and transmission lines at 110 kV, 230 kV, 400 kV and above. Alternating-current lines of 765 kV operate in some countries, and direct-current links at 1,100 kV have been built. X-ray tubes for medical imaging operate at tens of kilovolts, and insulation tests often apply several kilovolts. In nanovolts, a 11 kV system is 1.1 × 10^13 nV, and a 765 kV line is 7.65 × 10^14 nV. Nobody uses those expressions in practice, but they set the scale for the dynamic range of a measuring system. An instrument that has to measure both 100 nV signals and 10 kV supplies would need a range of 10^11. The converter exists for such comparisons.
A second example across the whole range
Take 750 nV, a plausible output of a strain gauge amplifier stage before gain. In kilovolts that is 7.5 × 10^-10. Take 5 V, a typical logic supply. In nanovolts that is 5,000,000,000. Take 1 kV and 1 nV and the ratio between them is 10^12. A system with a 24-bit analog-to-digital converter and a 5 V full scale has a smallest step of about 0.3 µV, which is 300 nV, since 5 divided by 16,777,216 is about 2.98 × 10^-7 V. Picking out nanovolt-level signals therefore needs gain, averaging or a better converter. These examples use made-up and textbook values to show the scale. The conversion on the page works for any number, including negative voltages, because it only multiplies by a constant.
Reading very small outputs
The output for small inputs is a very small decimal, and it may appear in exponent form. The notation 1e-11 means 1 × 10^-11. A missing minus sign in the exponent would describe a huge number, so check it. When pasting results into a spreadsheet, make sure the cell is formatted as a number so that the exponent is parsed. For reports, scientific notation with two or three significant figures is better than a string of zeros. If the point of the exercise is to compare voltages, it may be easier to compare them in a common unit such as volts: 10 nV is 0.00000001 V and 1 kV is 1,000 V. The ratio is the same however it is written, and a ratio of 10^-11 means the nanovolt value is a hundred billionth of the kilovolt value.
Common mistakes
A frequent mistake is to confuse nV with mV or with MV. The first slip changes the answer by a factor of one million, and the second by a factor of 10^15. Case matters in prefixes: m is milli and M is mega. Another is to apply the conversion to a quantity that is not a voltage, such as a current or a power. A third is to treat an RMS value, a peak value and a peak-to-peak value as interchangeable. The conversion changes the unit and leaves the kind of value unchanged, so label which one it is. A fourth is to treat a very high or very low voltage as meaningful without a reference. Voltage is a difference between two points, and a statement of a voltage should say which two.
Instrumentation chains and dynamic range
Measurement systems are described by their dynamic range, the ratio between the largest and the smallest voltage they handle. A digital multimeter might cover from 100 nV resolution on its lowest range to 1 kV on its highest, which spans ten orders of magnitude between 10^-7 V and 10^3 V. No single input stage covers all of that, so the instrument switches ranges with attenuators and amplifiers. Expressing both ends in nanovolts makes the ratio concrete: 100 nV against 10^12 nV. The converter can show those numbers, although the real design questions are about noise, input impedance and insulation. A reading of 100 nV is 1 × 10^-10 kV, and a stray offset of 0.5 µV, which is 500 nV, is 5 × 10^-10 kV. Written side by side in one unit, such figures show at a glance which contributions to an error budget are comparable and which are negligible. Whenever a specification lists voltages in different prefixes, writing them all in one unit reveals whether the claimed range is plausible.
Signal amplification from nanovolts to usable levels
A bioelectric or thermoelectric signal in the nanovolt to microvolt range must be amplified before it can be digitized. An amplifier with a gain of 1,000 turns 750 nV into 750 µV, and a gain of 1,000,000 turns it into 0.75 V. Instrumentation amplifiers with low noise reach input-referred noise densities of a few nanovolts per root hertz, which is why the noise in a 1 kHz bandwidth is on the order of 100 nV. The signal-to-noise ratio is then the signal voltage divided by the noise voltage, computed in a common unit. With a 750 nV signal and 129 nV of noise, the ratio is about 5.8. These figures are examples that follow the arithmetic, and a real design depends on the source impedance, the bandwidth and the amplifier chosen.
Scope and sources
The page converts a known voltage between SI-prefixed units. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it makes no statement about safety near high voltage. Work on energized equipment follows the rules of the applicable electrical code and must be done by qualified people. The volt and the prefixes are defined in the BIPM SI Brochure, and the prefix values are listed in NIST Special Publication 811. For design, rely on the specifications of the equipment and the standards that govern it.