Two traditions of writing conductivity
Building and insulation standards state thermal conductivity in watts per meter kelvin or milliwatts per meter kelvin. Semiconductor, ceramics and cryogenics references often use watts per centimeter kelvin. A designer who reads the thermal data of a silicon chip next to the datasheet of a foam gap filler, or a student who works through a materials table in one unit and a product sheet in another, meets both. This page multiplies the mW/(m·K) value by 0.00001 and gives W/(cm·K). The conversion changes two things at once: the milliwatt becomes a watt, which divides by 1,000, and the meter in the denominator becomes a centimeter, which divides by another 100. The two steps are worked out in the next section.
Working out the factor
One milliwatt per meter kelvin is 0.001 W/(m·K). One meter is 100 cm, so a conductivity per meter is a hundredth of the same conductivity per centimeter: heat flows through a centimeter-long path 100 times more easily than through a meter-long path for the same gradient, and 1 W/(m·K) equals 0.01 W/(cm·K). Combining the two steps gives 0.001 × 0.01 = 0.00001. The relationship is exact, since both the prefixes and the meter to centimeter ratio are defined. A check: 100 W/(m·K) is 1 W/(cm·K), and 100,000 mW/(m·K) is therefore also 1 W/(cm·K), which matches the factor in the other direction.
Ten milliwatts per meter kelvin in W/(cm·K)
The default of 10 mW/(m·K) gives 0.0001 W/(cm·K). A value of 26 mW/(m·K), typical of still air near room temperature, gives 0.00026 W/(cm·K). A foam at 35 mW/(m·K) gives 0.00035. In the reverse direction, 0.0004 W/(cm·K) equals 40 mW/(m·K). These numbers are small, so exponent forms such as 2.6 × 10^-4 W/(cm·K) are easier to copy. The result being smaller than the input by a factor of 100,000 is a good check. If you see a larger number, the direction of the conversion has been reversed or the wrong units were selected.
Semiconductors and heat spreaders
Silicon has a thermal conductivity of about 150 W/(m·K) near room temperature, often written as roughly 1.5 W/(cm·K). Copper is near 400 W/(m·K), or 4.0 W/(cm·K), and diamond can exceed 20 W/(cm·K). These values come from commonly quoted reference tables, and they vary with purity, temperature and crystal quality. Compared with air at 0.00026 W/(cm·K), silicon conducts heat about 5,800 times better. For a designer, this explains why a thin air gap under a heat sink matters so much, and why thermal interface materials are used. The page lets you place gas and foam values in the same unit as the solids.
Thermal interface materials
Thermal pads and greases for electronics are specified in W/(m·K), typically 1 to 10 for common products, which is 0.01 to 0.1 W/(cm·K). A pad at 6 W/(m·K) is 0.06 W/(cm·K), and one at 3 W/(m·K) is 0.03 W/(cm·K). Compared with a conductor at 4 W/(cm·K) the pad is much lower, which is why pad thickness is kept as small as the assembly allows. These ratings come from test methods that depend on pressure and thickness, so the datasheet figure is only part of the picture. The page handles the unit, and the thermal resistance of the joint should be taken from the manufacturer's data at your clamping pressure. A pad 1 mm thick at 0.06 W/(cm·K) has a resistance per area of 0.1 cm / 0.06 = 1.67 cm²·K/W, before contact resistance at the two faces is added.
Converting W/(cm·K) back to mW/(m·K)
To go the other way, choose watts per centimeter kelvin as the source and milliwatts per meter kelvin as the target. A value of 1.5 W/(cm·K) equals 150,000 mW/(m·K), and 4.01 W/(cm·K) equals 401,000 mW/(m·K). The page multiplies by 100,000. In W/(m·K) the same values are 150 and 401, using the watts per meter kelvin option. Large numbers of milliwatts per meter kelvin are rare in practice, which is why a solid is normally written in W/(m·K). When converting, record the temperature at which each conductivity was measured, since that varies the value, especially for crystals at low temperature.
Mixing up the length unit
The usual error is to forget the length in the denominator. A reader sees 1.5 and assumes W/(m·K), which gives a value 100 times too small, and a thermal model built with it will understate heat flow by two orders of magnitude. A second error is mixing watts per centimeter kelvin with watts per square centimeter kelvin, which is a heat transfer coefficient and not a conductivity. Units that contain a length in the denominator describe the material, and units with an area describe a surface. If a datasheet unit looks unfamiliar, write it out in base units before converting, and check the dimension.
Temperature dependence and anisotropy
Thermal conductivity changes with temperature. For silicon it falls as the temperature rises above room temperature, and for gases it rises. Layered and fibrous materials conduct differently along and across their structure. A single number in a table is a value for one temperature and one direction. When two sources disagree, the first thing to compare is the test temperature and the orientation of the sample, before suspecting a conversion error. The page converts the number you enter and does not know the conditions.
Quoting insulation conductivity to a sensible number of digits
The factor is exact, so the result has the digits of the input. Thermal conductivity measurements have uncertainties of several percent, and quoting a converted value with many digits adds nothing. The page does not calculate heat flow, thermal resistance, junction temperature or any design margin. For those, use the manufacturer data, the material tables at the right temperature and a proper thermal model. A useful habit is to write the conductivity with its unit and temperature in the same cell, for example 26 mW/(m·K) at 25 °C, so that a later conversion carries the conditions with it.