Picosiemens in the lab

Picosiemens appear in two places that rarely meet. In electrophysiology, the conductance of a single ion channel is quoted in pS, usually tens of them. In electrometry, the leakage across a good insulator or a guarded input is in the picosiemens range. Millisiemens belong to the ordinary electronics bench. This page puts a millisiemens value on the picosiemens scale by multiplying by one billion, so that a student can see how far an ion channel is from a resistor, or a technician can compare a test fixture with the leakage it must resolve. The page restates a number and does not simulate any cell or circuit. Because the factor is so large, small mistakes in the exponent are common, and writing the unit next to the number at every step of a calculation is the cheapest protection.

Nine places of difference

Milli is 10^-3 and pico is 10^-12, so one millisiemens is 10^9 picosiemens, and pS = mS × 1,000,000,000. The BIPM SI Brochure defines the siemens and lists the prefixes, and the conversion is exact. The result has nine more digits than the input has before the decimal point. A cross-check goes through nanosiemens: multiply by one million, then by 1,000. For 0.5 mS that gives 500,000 nS and 500,000,000 pS. Use exponent form for large outputs, as 5e8 pS is easier to copy than a long string of zeros, and group digits in threes when you must write them out.

Ten millisiemens in picosiemens

The default 10 mS gives 10,000,000,000 pS, ten billion. This is a resistance of 100 ohms. The long number is a reminder that the picosiemens scale is not made for such conductances. A more fitting use is to start from a small number and go down the scale: 0.000005 mS is 5,000 pS or 5 nS, and 0.00000002 mS is 20 pS. Ion channel conductances sit in this last range. The default is therefore best used as a check of the factor, and for practical work you enter the small value that you have, in whichever unit it arrives, and let the page do the rescaling.

Single ion channels

A single ion channel in a cell membrane opens and closes, and the current through it at a given voltage gives its conductance. Reported values for common channels range from a few picosiemens to a few hundred, with many in the tens. A 20 pS channel at a driving force of 60 mV passes 20e-12 × 0.06 = 1.2 pA. That current is just within reach of a patch-clamp amplifier. Converting 20 pS to mS gives 0.00000002 mS, which shows why the pS unit exists. These numbers are illustrative of order of magnitude, and the conductance of a real channel depends on the ion, the solution and the voltage. The page does not analyze recordings.

Insulators and electrometers

A resistance of 1 teraohm conducts 1 pS, and 100 gigohms conducts 10 pS. Electrometers and picoammeters work in this range, and the test fixture, cables and connectors must have leakage far below the quantity under test, which means clean guarded designs and low-humidity conditions. A fingerprint on an insulator can carry a conductance of nanosiemens, thousands of times more than the part under test. When you compare a fixture specification given in mS with a measured value in pS, the page puts the two on one scale so that you can see whether the margin is real. It does not replace the instrument manual.

From pS back to mS

To convert in the other direction, choose pS as the source and mS as the target. A value of 100 pS equals 0.0000001 mS, and 20 pS equals 0.00000002 mS. Divide by one billion. The result has many leading zeros, so use the exponent form 1e-7 and 2e-8 for software. If you want a more readable middle step, convert pS to nS first: 100 pS is 0.1 nS, and 5,000 pS is 5 nS. A column that mixes pS and nS entries is a frequent cause of errors in laboratory notebooks, so convert everything to one unit before computing averages or fitting a model. Plotting software also prefers a single unit on each axis, and a label such as conductance (pS) tells the reader how to read every tick mark.

Reading units on a datasheet

The symbol pS has a capital S, and lowercase ps means picosecond. A datasheet that lists leakage in pA and a voltage can be turned into a conductance by dividing the current by the voltage: 50 pA at 5 V is 10 pS. The page does not do that division, but it helps afterward when you want the number in mS or nS. Datasheets also list conditions such as temperature and humidity, and the conductance can change by an order of magnitude over a temperature range, so keep the conditions with the number when you copy it elsewhere. A good habit is to note the voltage at which a leakage was measured, because many insulators are not ohmic and the conductance computed at 5 V can differ from the value at 50 V. A conductance quoted without a voltage or a temperature is incomplete.

Digits in a picosiemens result

The result is the input followed by nine added zeros, with no new digits of precision. Measurements at the picosiemens level have large relative uncertainty, often ten percent or more, because of noise and drift. Quote one or two significant digits. The page keeps full precision internally and rounds only the displayed result, so a chain of conversions does not accumulate errors. If you average many channel measurements, convert each one first and average afterward, or convert the average once, since both routes give the same result for a pure scale factor.

Filter and holding-voltage effects on pS values

The page changes the unit of a conductance. It does not analyze electrophysiology data, measure leakage, certify an insulator or compute noise. For research use the methods of your field, the instrument documentation and the guidance of your lab. A single recording is also affected by the filter bandwidth and the holding voltage, which are recorded in the methods section of a paper. A converted number copied into a figure caption should carry the same conditions as the original.