Leakage lives in nanosiemens
A circuit board, an insulator or a capacitor never insulates perfectly, and the leftover conduction is measured in nanosiemens, sometimes picosiemens. A switch contact or a resistor is measured in millisiemens or siemens. This page links the two ends. Type the millisiemens value, keep nanosiemens as the target and read the same conductance on the finer scale. The factor is one million because milli and nano are six powers of ten apart. Leakage values in a datasheet are often given for one temperature, commonly 25 °C, and rise sharply when the part gets hot. Typical users are electronics students working with leakage current, technicians who compare an insulation resistance with a signal path, and anyone reading a datasheet that lists input leakage next to transconductance. The page restates a number and does not model any circuit. A reading such as 0.0003 mS is awkward to say aloud and easy to miswrite, while 300 nS reads naturally and matches the way datasheets list leakage.
Six decimal places
Milli is 10^-3 and nano is 10^-9, so one millisiemens contains 10^6 nanosiemens and nS = mS × 1,000,000. The siemens is one ampere per volt in the BIPM SI Brochure, and the prefix definitions are exact, so the conversion carries no uncertainty. A simple route for a check by hand goes through microsiemens: multiply by 1,000, then by 1,000 again. For 2.5 mS the first step gives 2,500 µS and the second 2,500,000 nS. The output has six more digits than the input, so group the digits in threes to catch a missing zero before it reaches a report.
Ten millisiemens in nanosiemens
The default of 10 mS gives 10,000,000 nS. That is ten million nanosiemens for a resistance of 100 ohms. The default sits at the far end of the nanosiemens scale, where numbers are long. Instruments that read nanosiemens typically cover a few nS to a few hundred nS, so a result in the millions is not something such a range could show. For comparison, 1 mS is 1,000,000 nS, 0.001 mS is 1,000 nS and 0.000001 mS is 1 nS. Those steps show how quickly the numbers shrink as a conductance moves toward an insulator, and they give anchors for judging inputs before reading the output.
Insulation and leakage as resistance
Leakage is usually given as a resistance. A resistance of 1 gigohm has a conductance of 1 nS, and 10 megohms conducts 100 nS, which is 0.0001 mS. A resistance of 5 megohms conducts 200 nS, or 0.0002 mS. With a 5 V supply, 200 nS leaks 5 × 200e-9 = 1 µA. Such currents matter in low-power designs, where a sleeping circuit may draw only a few microamperes in total. Converting between mS, µS and nS lets you compare a leakage path with the intended load on one scale. The numbers shown here are illustrative, and actual leakage depends on humidity, surface contamination and temperature.
Measuring small conductances
Some digital multimeters offer a conductance range of 60 nS, with a resolution of 0.01 nS, which is a way to measure resistances above about 100 megohms. The reading is sensitive to humidity and to the cleanliness of the test leads and fixture. Touching the probe adds the conductance of skin, which is often in the range of microsiemens, far above the quantity under test. For serious insulation work, use an insulation tester or an electrometer, and follow the method of the standard for your equipment. The page only converts the numbers you read from an instrument.
From nS back to mS
To go the other way, choose nS as the source and mS as the target. A value of 250 nS equals 0.00025 mS, and 1 nS equals 0.000001 mS. Divide by one million. Such results have many leading zeros, so the exponent form 2.5e-4 is safer for pasting into software. If a datasheet says input leakage of 100 nA at 5 V, the conductance of that leak is 20 nS, which is 0.00002 mS. Check the direction of your calculation by asking whether the result should be larger or smaller than the input. Going to the larger unit always makes the number smaller.
Biology and electrochemistry
Membrane and electrode work uses nanosiemens for whole-cell conductances, which are often in the range of a few to a few hundred nS. Patch-clamp recordings quote cell input conductance in nS and single-channel conductance in pS. An electrode in a sensor can have a conductance that spans from nS in dry air to mS in a salty solution, a ratio of a million. Converting to one unit makes plots on a logarithmic axis consistent, and it prevents a dataset that mixes mS and nS from being fitted wrongly. The page covers only the unit conversion and not the interpretation of any recording. When a recording protocol states a seal resistance in gigohms, take the reciprocal first, since 1 GΩ is 1 nS, and then convert with the page if you need another unit.
Symbols and digits
The symbols are mS for millisiemens and nS for nanosiemens. The letter n and the letter m look alike in small print, and a mix-up changes the value by a factor of one million. Write the unit next to every number and avoid unlabeled columns. The converted value has the same significant digits as the input, because the factor adds only zeros. Values copied from a bench meter often carry a trailing digit that is just noise, so trim to the stable digits before converting. A spreadsheet that stores nanosiemens as text will not sort correctly, so keep the cells numeric and put the unit in the header. A reading of 0.0002 mS has one significant digit, so 200 nS is the proper form, and 200.000 nS would overstate the precision.
Recording analysis beyond the nS value
The converter expresses a millisiemens value in nanosiemens and does no analysis of the part. It does not measure leakage, predict insulation life, evaluate a circuit or check a product against a safety standard. Those tasks need the proper instruments, the rules for your equipment and, in many cases, a qualified person. A converted number is only as good as the reading it came from, and conductance at this level depends on the humidity of the room, the cleanliness of the surface and how long the voltage has been applied.