Liquids in mPa·s, gases in µPa·s
Liquid viscosities are usually quoted in millipascal-seconds, and gas viscosities in micropascal-seconds, because gases are so much thinner. Water at 20 degrees Celsius is about 1.0 mPa·s, while air at the same temperature is about 18 µPa·s. A lab report that compares a coolant, a lubricant and the air or nitrogen around it needs both in one unit. This page multiplies the mPa·s value by 1,000, so a liquid figure reads in µPa·s and sits next to the gas values. It is also handy for microfluidics work and for checking a paper that mixes the two conventions in its tables, where one row reads 0.89 and another reads 18.5 with no hint of the unit change.
Why 1 mPa·s is 1,000 µPa·s
The prefix milli stands for 10^-3 and micro for 10^-6, so one millipascal-second contains 1,000 micropascal-seconds. The pascal-second is the SI unit of dynamic viscosity, defined in terms of the pascal and the second in the BIPM SI Brochure, and NIST SP 811 lists the prefixes. The factor is exact. Moving from mPa·s to µPa·s shifts the decimal point three places to the right. A quick check is to divide the result by 1,000 and recover the input. The default of 10 mPa·s gives 10,000 µPa·s, and the page shows both numbers with their full unit symbols so that the direction is clear.
Worked examples with everyday fluids
Water at 20 degrees Celsius has a viscosity near 1.002 mPa·s, which the page converts to 1,002 µPa·s. Air at the same temperature has about 0.0181 mPa·s, or 18.1 µPa·s, so water is roughly 55 times as viscous. Entering 0.5 mPa·s gives 500 µPa·s, a figure typical of water at about 70 degrees Celsius. A thick fluid such as glycerol, at about 1,400 mPa·s near 20 degrees, becomes 1,400,000 µPa·s. These are approximate handbook-style values, and real samples vary with temperature and composition, so use the figure from your own datasheet or measurement. Whole milk, at roughly 2 mPa·s, comes to about 2,000 µPa·s, and a light machine oil at 30 mPa·s becomes 30,000 µPa·s. Placing such values in a single column makes the spread visible, from tens of thousands for oils down to the tens for gases.
Temperature changes the number
Liquid viscosity falls sharply as temperature rises, and gas viscosity rises slightly. Water drops from about 1.0 mPa·s at 20 degrees Celsius to roughly 0.55 mPa·s at 50 degrees, while air climbs by a few percent over the same step. A viscosity figure without its temperature is nearly meaningless, and a converted value inherits that problem. When you convert a number from a table, copy the temperature along with it. Oils are particularly sensitive. A lubricant that reads 100 mPa·s at 40 degrees may read far less at 100 degrees, which is why oil grades state viscosity at two temperatures.
Converting back from micropascal-seconds
Choose micropascal-seconds as the source and millipascal-seconds as the target to divide by 1,000. A gas value of 18.1 µPa·s gives 0.0181 mPa·s, and 1,780 µPa·s gives 1.78 mPa·s. This direction is common when a gas viscosity from a reference table has to be entered into a formula that expects mPa·s, or when a simulation tool uses a single unit for every fluid in the model. Keep the unit symbols with the numbers throughout the calculation. If an answer looks off by a factor of 1,000, check whether the two selections are in the intended order.
Viscometer readouts and spec sheets
Rotational viscometers often display viscosity in mPa·s or in centipoise, and the two numbers are the same, since 1 cP equals 1 mPa·s. A paint or coating data sheet may give the value at a stated spindle speed and temperature. Capillary and falling-ball methods give results in the same units. Micropascal-seconds are rarely shown by a liquid viscometer, so the conversion comes up mainly when you want a common scale with gas data from another source. A microfluidics lab that models an air-water interface, for example, may keep every viscosity in µPa·s so that a liquid at 890 µPa·s, which is 0.89 mPa·s for water near 25 degrees Celsius, and air at 18.5 µPa·s appear in one column. The ratio of the two, about 48, is then easy to read directly from the table. When copying a figure from a spec sheet, note the method and conditions with it, because shear-thinning fluids give different numbers at different speeds.
Dynamic and kinematic viscosity
The pascal-second measures dynamic viscosity, the resistance to flow under shear. Kinematic viscosity divides it by density and is quoted in square meters per second or centistokes. The page converts only dynamic viscosity units, so a number in cSt or mm²/s needs the density before it can become mPa·s. For water the two are almost equal, 1 mm²/s being about 1 mPa·s at 20 degrees Celsius, but for oils with densities near 0.9 g/cm³ the difference is about ten percent. Confirm which one a datasheet reports before entering it here, since the symbols look alike and the mistake is easy to make. A motor oil sheet that lists 9 mm²/s is not 9 mPa·s.
Notation of the micro sign
The symbol µPa·s uses the Greek letter mu and a middle dot between Pa and s. Plain-text systems may turn it into uPa.s or drop the dot, leaving uPas, which can be misread. Be consistent and spell the unit out at first mention. Another point to check is the letter P. A capital P alone is the poise, an older unit, while Pa is the pascal. A value written as mP would be a millipoise, equal to 0.1 mPa·s, so a lost letter leads to a tenfold error. Keep Pa·s together as a unit and never split it across cells.
Gas viscosity beyond the unit change
The page converts a viscosity between two units that differ by a power of ten. It does not correct for temperature, estimate a viscosity from composition, convert kinematic to dynamic values or judge whether a fluid suits a pump or a process. Those questions depend on the application. Use the page to align numbers in a table or a calculation and take the fluid properties from your supplier or from a measurement at the working temperature.