What viscosity value this page converts
Dynamic viscosity describes how strongly a fluid resists shear, which is the sliding of one layer over another. Gases are usually tabulated in micropascal-seconds, while liquids are tabulated in millipascal-seconds or centipoise. A reader comparing the viscosity of a gas with that of a liquid therefore has to bring the numbers to one prefix. This converter takes a value in µPa·s and returns mPa·s. Air at room temperature, about 18.1 µPa·s, becomes 0.0181 mPa·s, which can be set directly beside the 1.0 mPa·s of water. The page changes the prefix only. It does not predict how a fluid will flow in a pipe or what pump you need, and it does not convert dynamic viscosity into kinematic viscosity, which requires density. Textbooks use either the Greek letter mu or eta for dynamic viscosity, and both mean the same property, so a table headed with either symbol can be converted directly.
Definition of the pascal-second
The pascal-second is the SI unit of dynamic viscosity. One pascal-second is the viscosity of a fluid that, between two plane parallel surfaces one meter apart moving at one meter per second relative to each other, produces a shear stress of one pascal. In base units it is one kilogram per meter per second, or one newton-second per square meter. The micro prefix means 10⁻⁶ and the milli prefix means 10⁻³. A micropascal-second is therefore a thousand times smaller than a millipascal-second, and the page formula is mPa·s = µPa·s × 0.001. Both prefixes come from the SI Brochure of the BIPM and are exact. No density, temperature or pressure appears in the factor, because both units describe the same property. Because the pascal is a newton per square meter, the pascal-second also equals a newton-second per square meter, and that form makes it clear why viscosity connects stress to the rate of strain. Shear stress in pascals equals viscosity in pascal-seconds times shear rate in reciprocal seconds.
The default example
The page starts with 10 µPa·s. Multiplying by 0.001 gives 0.01 mPa·s. The unrounded result may display as 0.009999999999999998 because of binary floating-point arithmetic, and the intended value is 0.01 mPa·s. A simple check goes through pascal-seconds: 10 µPa·s is 0.00001 Pa·s, and 0.01 mPa·s is also 0.00001 Pa·s. For a quick mental conversion, move the decimal point three places to the left. 18.1 becomes 0.0181, and 8.8 becomes 0.0088. If your conversion produces 10,000 or 0.00001, you probably used the wrong prefix pair, such as converting to pascal-seconds or to nanopascal-seconds. Remember that the result always carries a smaller number, since you are expressing the same viscosity with a larger unit. Ten micropascal-seconds is far thinner than any liquid and close to the viscosity of hydrogen gas, which is about 9 µPa·s.
Gas viscosity in micropascal-seconds
Gas viscosities are small. Air at 20 °C is about 18.1 µPa·s, and hydrogen is about half of that, near 9 µPa·s, while carbon dioxide is somewhat lower than air. Converted, air is 0.0181 mPa·s and hydrogen is about 0.009 mPa·s. These values are approximate and depend on temperature. Unlike liquids, gases become more viscous as they warm up, because the faster molecules transfer momentum more effectively. Air at 0 °C is near 17.2 µPa·s, and at 100 °C it climbs to roughly 21.9 µPa·s. Reference tables from NIST or the CRC Handbook list precise values for specific gases and temperatures. When you carry such a number into a calculation, write the temperature beside it, because a viscosity without a temperature is incomplete. Kinetic theory predicts that gas viscosity is nearly independent of pressure over a wide range, a result first noted by James Clerk Maxwell, which is why tables of gas viscosity are usually listed against temperature alone.
Liquid viscosity in millipascal-seconds
Liquids span a wide range. Water at 20 °C has a viscosity of about 1.0 mPa·s, more precisely 1.002. Whole blood is commonly quoted around 3 to 4 mPa·s, though it depends on shear rate and hematocrit. Glycerol at 20 °C is near 1,400 mPa·s, which is 1.4 Pa·s. Comparing a gas and a liquid shows the gap: water is roughly 55 times as viscous as air, because 1,002 µPa·s divided by 18.1 µPa·s is about 55. Water viscosity falls with temperature, to about 0.55 mPa·s at 50 °C. That trend is the reverse of what happens in gases. Always check the temperature when comparing published values, as the temperature effect can exceed the difference between two similar fluids. Pure water at 0 °C is far thicker than at 20 °C, at about 1.79 mPa·s, which shows how much a modest temperature change matters.
Poise and centipoise
The older CGS unit of dynamic viscosity is the poise, named for the physician Jean Léonard Marie Poiseuille. One poise equals 0.1 Pa·s, and one centipoise equals 0.01 poise, which is exactly 1 mPa·s. This is why water is often described as having a viscosity of 1 cP. In practice, a value in millipascal-seconds and the same number in centipoise are identical, so the result on this page can be read directly as centipoise: 18.1 µPa·s is 0.0181 mPa·s, and therefore 0.0181 cP. Older literature, especially in petroleum, paint and food work, still uses centipoise, so you will see both. The dropdown on this page lets you choose poise and centipoise directly when that is what you have. Likewise, the stokes and centistokes of the CGS system belong to kinematic viscosity, so a centistoke figure cannot be read as centipoise unless the density is exactly one gram per cubic centimeter.
Dynamic versus kinematic viscosity
Dynamic viscosity and kinematic viscosity are different quantities, and one cannot be converted into the other without density. Kinematic viscosity is the dynamic viscosity divided by the fluid density, and it is measured in square meters per second, or in stokes. For air at 20 °C, with a dynamic viscosity of 18.1 µPa·s and a density of about 1.204 kg/m³, the kinematic viscosity is about 1.5 × 10⁻⁵ m²/s. For water, with 1.002 mPa·s and a density near 998 kg/m³, it is about 1.0 × 10⁻⁶ m²/s. Water is much more viscous in dynamic terms, but its kinematic viscosity is only about one fifteenth of air's, because it is so much denser. This page converts dynamic viscosity prefixes only, and it applies no density.
A second worked example
Suppose a table lists the viscosity of a gas as 18.1 µPa·s and you want the value in mPa·s. Multiply 18.1 by 0.001 to get 0.0181 mPa·s. A liquid example: 1,002 µPa·s equals 1.002 mPa·s. Taking the ratio of the two results, 1.002 divided by 0.0181, gives about 55.4, the viscosity ratio between water and air at about 20 °C. Both source values are approximate, and the example is meant to show the mechanics rather than to supply reference data. If you need a viscosity that is reliable to several digits, take it from a primary reference such as the NIST Chemistry WebBook or an equivalent standard source, and note the temperature and pressure for which it applies.
Temperature and measurement conditions
A viscosity number means little without the temperature at which it was measured. Liquids usually thin as they warm, sometimes dramatically. Motor oils are rated by how their viscosity changes between cold and hot. Gases thicken slightly with temperature. Pressure has a small effect on liquids and gases at ordinary pressures, but it becomes significant at very high pressure. Measurement instruments differ as well. Capillary viscometers time the flow of a fluid through a narrow tube, rotational viscometers measure the torque needed to turn a spindle in the fluid, and falling-ball methods time a sphere sinking through it. Each method suits a particular range. If two sources quote different numbers for the same fluid, compare their temperatures and methods first. Standards organizations such as ASTM International publish test methods for the viscosity of petroleum products, and those methods fix the temperature and apparatus so that results from different laboratories can be compared.
Newtonian and non-Newtonian fluids
A single viscosity number describes a Newtonian fluid, in which shear stress is proportional to shear rate. Air, water and many simple oils behave that way. Many other fluids do not. Ketchup, paint, blood and polymer solutions change apparent viscosity with the rate at which they are sheared. For those fluids, a quoted value belongs to a stated shear rate or measurement condition, and converting the prefix leaves that condition unchanged. A value listed as 3,500 mPa·s at 10 per second is a different number from the value at 100 per second. The converter treats whatever you enter as a number in a given unit. It does not check whether a single value is meaningful for the fluid you have in mind. The geometry of the instrument can also affect the number for such fluids, so a stated measurement setup belongs next to the value.
Scope of the page
This is a prefix conversion between micropascal-seconds and millipascal-seconds. It does not convert dynamic and kinematic viscosity, which differ by density, and it does not estimate flow, pressure drop or pumping requirements. For definitions and exact prefixes, see the BIPM SI Brochure, and for property data consult a primary reference. Keep the original unit and temperature beside each converted value so that anyone using the result can verify the source. If you need to carry a viscosity into a pressure-drop or Reynolds-number calculation, convert to pascal-seconds first, because most engineering equations expect base SI units and a stray prefix will shift the result by powers of ten.