Two unit systems on the same sheet

Magnet suppliers in the United States, older test procedures and many textbooks give field strength in oersteds, while European data sheets and current standards use kA/m. Anyone who sources magnets, writes a test plan or reads a paper from the other tradition ends up converting. This page performs the step. Enter the field in kA/m, keep the target on oersteds, and read the equivalent. The factor contains π, so doing it by hand with a calculator is tedious, and a single slip changes the answer by a visible margin.

Where the 12.5663706144 comes from

The oersted is defined in the CGS system so that 1 Oe equals 1,000 / (4π) A/m, about 79.5774715 A/m. NIST SP 811 lists this relation in its table of CGS units. Inverting it, 1 A/m equals 4π / 1,000 Oe, and 1 kA/m equals 4π Oe, which is 12.5663706144 Oe. The page applies the factor at full precision and rounds only the display. The reverse reference is 1 Oe at about 0.0795774715459 kA/m. Because the factor is irrational, no finite decimal reproduces it, so avoid rounding it early if the field value will feed a later calculation. A value rounded to 12.57 gives 125.7 Oe for the default, which is close, but repeated across a long chain of steps the rounding adds up.

The default of 10 kA/m

Entering 10 kA/m gives about 125.6637 Oe. That is the field produced by a coil of about 100 ampere-turns per centimeter, a modest value for a laboratory electromagnet. A field of 125.66 Oe also equals roughly 125.66 gauss in air, since in the CGS system the oersted and the gauss describe the same strength in vacuum, though they measure different quantities, H and B. The match breaks inside any magnetic material, where B and H are linked by permeability. Keep that distinction when a worksheet gives gauss and oersted in neighboring columns.

Magnet grades and coercivity

Sintered neodymium magnets are graded by remanence and coercivity. A common intrinsic coercivity requirement of 955 kA/m converts to about 12,001 Oe, which is why catalogs list 12 kOe for those grades. A buyer comparing a European quote in kA/m with a U.S. quote in oersteds can run both through this page to confirm that they describe the same grade. Grades made for higher operating temperatures list higher coercivity, for example 1,592 kA/m, which is about 20,006 Oe or 20 kOe. Matching the numbers avoids the mistake of reading a larger oersted figure as a stronger magnet when the underlying quantity is the same. Because one kA/m is about 12.6 Oe, any quote in oersteds will show a number roughly twelve times the kA/m figure.

Magnetic particle inspection

Magnetic particle inspection magnetizes a steel part so that surface flaws attract iron powder. Procedures often call for a tangential field strength of a few kA/m, and older U.S. documents give it in oersteds or as an approximate value in gauss. A field of 2 kA/m is 25.13 Oe, and a field of 6 kA/m is 75.40 Oe. A technician working from a procedure written in one unit and a meter calibrated in the other can use this page to check that the reading meets the requirement. If a probe reads 40 Oe on the surface of a part, the equivalent is 3.183 kA/m, which can then be compared with a procedure limit written in SI units. Always confirm the specification in force for the work, since the value depends on the standard being applied, the shape of the part and the direction of the field relative to the flaw you are looking for.

The Earth's field in oersteds

The geomagnetic field near the surface is about 0.5 gauss, which in air corresponds to a field strength of about 0.5 oersted. In SI that is about 39.8 A/m, or 0.0398 kA/m. Entering 0.0398 returns 0.5001 Oe, which matches within rounding. A shielding specification that asks for a residual field below 0.05 Oe asks for a reduction by a factor of ten from the ambient value, which is about 0.004 kA/m, or roughly 4 A/m, in SI terms. This is a handy reference point when a compass, a magnetometer or a shielding specification is quoted in oersteds. It also helps put larger numbers in context: the 10 kA/m default is about 250 times the Earth's field.

Going from oersteds back to kA/m

Switching the units converts an oersted reading to kA/m by dividing by 12.5663706144. The inverse factor, 0.0795774715, is the one to remember when a number in oersteds is small, since it gives kA/m directly. A reading of 1,000 Oe equals 79.5775 kA/m, and 12 kOe equals 955 kA/m. Data sheets from different regions rarely round in the same way, so a value of 12,000 Oe may come back as 954.9 kA/m, while a sheet may state 955. A magnet that a European vendor lists at 876 kA/m is about 11,008 Oe, and a U.S. vendor may round that to 11 kOe. Both are correct within the precision of the source. When you need to apply a tolerance, convert the limit and the measurement to the same unit before comparing, rather than comparing rounded values from two documents.

Writing a field requirement in both units

A test plan or purchase order that will be read in two regions should carry the requirement in both units, with a tolerance. A requirement of 100 Oe, plus or minus 5 percent, spans 95 to 105 Oe, which is 7.56 to 8.36 kA/m, since 100 Oe equals about 7.95775 kA/m. Computing the limits from the exact factor and rounding afterward keeps the two versions consistent. A supplier who sees only the oersted figure and a laboratory that measures in kA/m will then agree on pass and fail without a conversation, and the document stays correct if a rounded value is copied into a report.

Gauss, tesla and oersted are different quantities

The oersted is a unit of H, the magnetic field strength. The gauss and the tesla are units of B, the flux density. In air the numbers coincide in CGS, so people often swap the names, but a gaussmeter reads B, and a field written in oersteds describes the driving field that produces it. Converting kA/m to oersteds does not give you gauss unless the medium is air or vacuum. In a ferromagnetic part, the flux density is far larger. Keep each quantity in its own column to avoid combining values that cannot be compared directly.