Adjacent prefixes in high-frequency work

In radio-frequency and high-speed digital design, capacitances live at the boundary between femtofarads and picofarads. An oscilloscope probe adds around a picofarad or a few of them at the tip, a connector pad adds a fraction of one, and the input of a fast amplifier lists its capacitance in pF while the layout tool reports the trace in fF. People converting between exactly these two units are matching a datasheet number in pF with an extraction number in fF so both can be added. The converter handles the factor of 1,000, which is small enough to do mentally but frequent enough that errors creep in during long summations.

The relation 1 pF = 1,000 fF

Pico is 1e-12 and femto is 1e-15, both exact decimal prefixes in the SI Brochure and NIST SP 811. Therefore 1 pF equals exactly 1,000 fF, and pF = fF × 0.001. The page prints the factor as 0.00100000000000. Since the farad is defined as one coulomb per volt, the relationship does not depend on how the capacitance arises, whether from a dielectric gap, a junction or a wire over a ground plane. Any digit beyond the leading ones in the answer is a rounding product of floating point storage. To verify by hand, shift the decimal three places to the left going from fF to pF.

Reading the default of 10 fF

Entering 10 fF produces 0.010000000000000002 pF. The intended value is 0.01 pF, a hundredth of a picofarad. That is about the capacitance between two small pads separated by a short air gap, or the contribution of a short via, so it is realistic for a layout extraction number. On a 50 Ω RF line, a shunt capacitance of 0.01 pF at 1 GHz has a reactance of 1 / (2π × 1e9 × 1e-14), about 15.9 kΩ, which is large compared with 50 Ω, so the pad matters little there. At 100 GHz the same capacitance has a reactance of about 159 Ω, which does start to matter.

Example with 330 fF

A capacitance of 330 fF equals 0.33 pF. Suppose an input pin lists 1.2 pF and the board adds a pad extracted at 330 fF. Converting the pad to 0.33 pF lets you add the two: 1.2 + 0.33 = 1.53 pF. Adding without conversion, 1.2 + 330, would give a nonsense total. Next, a probe with 0.5 pF is 500 fF, and a 12 pF load is 12,000 fF. The exchange between the two scales is typical of a bring-up session where a datasheet in pF, a simulator in fF and a bench instrument in pF all contribute to one budget.

Converting from pF back to fF

The reverse multiplies by 1,000: 0.5 pF becomes 500 fF, 2.2 pF becomes 2,200 fF, and 12 pF becomes 12,000 fF. This direction is common when you want to enter a part value into a tool that uses fF by default, such as some layout and parasitic extraction flows. It also helps you find which of a long list of contributions dominates, because integers are easier to compare than decimals with leading zeros. After the conversion, sort by size, and the largest few entries usually account for most of the total load on the node. For instance, a load list of 1,200 fF for the amplifier pin, 330 fF for the pad and 45 fF for a via totals 1,575 fF, which is 1.575 pF, and the pin alone supplies about three quarters of it.

Probe loading and bandwidth

A passive oscilloscope probe at 10:1 typically presents on the order of 10 to 15 pF at its tip, while an active probe may present well under 1 pF, which is under 1,000 fF. With a source resistance of 1 kΩ, a load of 1 pF produces a time constant of 1 ns and a 3 dB bandwidth near 159 MHz, while 100 fF gives 0.1 ns and 1.59 GHz. These numbers are illustrative of the RC relation and not of a specific instrument. The conversion between fF and pF is the step that lets you place a probe datasheet value next to an extracted trace value.

Three-digit codes and the pF label

Small ceramic capacitors are often marked in pF with a three-digit code, where the first two digits are significant and the third gives the number of zeros, so 331 means 330 pF and 101 means 100 pF. Values below 10 pF may be marked with a letter, such as 4R7 for 4.7 pF. Femtofarad values do not appear on discrete parts because their tolerance would be larger than the value, which is why fF belongs to chip design and measurement. If you see a number in fF and want to buy a part, convert to pF first and expect the nearest standard value to be a fraction of a pF at the smallest.

Rounding and stray digits

The 0.010000000000000002 shown for the default includes a stray digit. The cause is binary floating point, which cannot store 0.001 exactly, and the effect is a relative error near 2e-16, far below any physical relevance. Round the result to the number of figures in your input. An instrument that reads 330 fF with three figures supports 0.330 pF, and nothing more. A value quoted as about 0.3 pF in a datasheet has one figure, so adding it to a 330 fF number gives a sum good to one or two figures at best. For documentation, state the unit with the number and keep one consistent prefix within a table so readers can compare values directly. Mixed columns, such as 0.33 pF beside 500 fF, invite a misread by a factor of 1,000.

Stray capacitance impact lies outside the page

The converter only expresses a capacitance in a different prefix. It does not determine how a stray capacitance affects a circuit, which depends on source impedance, frequency and layout. It does not model parasitic inductance, temperature drift or voltage dependence. For RF design, use measured S-parameters or manufacturer models and treat this page as a way to keep units straight when combining numbers from different sources. A final quick test: any fF value above 1,000 should give a result of at least 1 pF, and a result below 1 for a number under 1,000 confirms the prefix direction.