Parasitics and sensor signals in femtofarads

Capacitive touch controllers, MEMS accelerometers and integrated circuit layouts work with capacitances so small that the picofarad is a coarse unit. A touch on a sensor pad may change a mutual capacitance by a few hundred femtofarads, and a metal line inside a chip adds tens of femtofarads to a node. Datasheets and extraction reports for those parts write fF, while board-level parts lists write pF. This page multiplies the picofarad value by 1,000 so that both fit one scale. The default of 10 pF gives 10,000 fF, a number that makes it easier to see how small a change a sensor must resolve compared with the total capacitance on the line.

A step of one thousand

Femto is 10^-15 and pico is 10^-12, so a picofarad holds 1,000 femtofarads. The formula is fF = pF × 1,000. The prefixes are given in the BIPM SI Brochure and in NIST SP 811, and the ratio is exact. The decimal point moves three places to the right: 0.5 pF becomes 500 fF, and 2.2 pF becomes 2,200 fF. In the opposite direction, 750 fF is 0.75 pF. Because the page works in binary floating point, the default may display as 9999.999999999998 instead of 10,000, which is the same number to any practical precision, so round it before you copy it into a report. Rounding to three or four figures is plenty, since few instruments resolve a capacitance better than that.

Reading the default and its neighbors

With 10 pF the page shows 9999.999999999998 fF, which means 10,000 fF. Other inputs behave the same way: 1 pF gives 1,000 fF, 0.3 pF gives 300 fF, and 47 pF gives 47,000 fF. A quick test is to count the commas: every step from pF to fF adds a thousands group. If you are converting a long list, convert two or three values with the page and compare them with your spreadsheet before trusting the rest. An error of 1,000 in either direction is the most frequent slip with these two units, and a visual check of the result against the input catches it quickly.

Capacitive touch and proximity sensing

A touch panel or a proximity sensor detects an object through a small change in capacitance. Controller chips often report raw counts that correspond to femtofarads, and an illustrative finger touch may change the sensor capacitance by 0.3 pF, which is 300 fF, on a pad whose baseline capacitance is a few picofarads. Firmware thresholds are written relative to that baseline, so a unit mix-up can make a button too sensitive or dead. Converting the baseline and the expected change to one unit puts them on the same scale. The figures depend on the electrode geometry, the overlay thickness and the controller, so the data sheet and a measurement on your own board decide the real values.

MEMS sensors and tiny differences

A MEMS accelerometer converts motion into a change in capacitance between a movable structure and fixed electrodes. The total capacitance is typically a few picofarads, and the change produced by an acceleration of 1 g is a small fraction of that, in the range of femtofarads. Reading a data sheet that quotes both numbers requires a consistent unit. If the sensing capacitance is 2.2 pF, that is 2,200 fF, and a change of 20 fF is under one percent of the total. This ratio is what the readout circuit must resolve, and expressing both numbers in fF makes it visible. The page only converts the unit and does not model the sensor. Datasheets for such parts may state the sensitivity as a change in femtofarads per g, so a quick conversion keeps the readout electronics specification and the sensor specification in the same unit.

Probe and pad capacitance during measurement

The act of measuring adds capacitance. A passive 10x oscilloscope probe has an input capacitance of roughly 10 pF to 15 pF, which is 10,000 fF to 15,000 fF, and a bare probe tip on a small node can disturb a circuit that has only a few picofarads. This is one reason that high-frequency measurements use active probes with much lower input capacitance, quoted around 1 pF or less, which is 1,000 fF. When you compare the capacitance of a node with that of the probe, put them in the same unit, then judge the share. The converter helps with the unit, and the probe manual gives the actual figure for your model. Keep the ground lead short as well, because its inductance adds ringing that can be mistaken for a capacitance effect.

Simulator suffixes: f is femto

In SPICE-style simulators, the suffix f stands for femto, which is 10^-15, and because the suffixes are not case sensitive, writing 10F does not mean ten farads, it means ten femto. That trap catches new users who type a capacitor value with the unit symbol. Writing 2.2p for picofarads and 300f for femtofarads is accepted. When you copy numbers from an extraction report that lists fF, check what the netlist prefix is, and compare with this page by converting one value. A mismatch of 1,000 means a pF and fF mix-up, and a mismatch of 10^12 means a bare F was interpreted as femto.

From femtofarads to picofarads

Set femtofarads as the From unit to move the other way. A node with 1,800 fF is 1.8 pF, 450 fF is 0.45 pF, and 25 fF is 0.025 pF. Parasitic extraction tools often list many small contributions in fF, and the total is easier to compare with a design budget in pF. For example, five contributions of 120 fF, 80 fF, 200 fF, 45 fF and 155 fF add up to 600 fF, which is 0.6 pF. Adding them in fF avoids long decimals, and one conversion at the end gives the figure to compare against the budget. Keep the individual contributions in the report so that a reviewer can see where the capacitance comes from.

Meter resolution decides how many femtofarad digits are real

The page restates a capacitance in a smaller unit. It does not extract parasitics, predict a sensor reading, calculate the settling time of a node or judge whether a layout is acceptable. Measurements at this scale depend on the instrument, the fixture and the frequency, and an LCR meter may specify a resolution of only tenths of a picofarad. A reading of 0.5 pF on such a meter is 500 fF, but the last digit may be noise. Use the manufacturer specifications to decide how many figures are meaningful, and report the converted number with the same precision as the measurement.