Measurement basis
A capacitance in farads already uses the group’s reference scale.
Definition conventions
Prefixes use SI decimal powers, and conversions remain within capacitance.
Conversion method
Keep F unchanged for the reference. Divide by a target capacitance factor for another prefix.
Reference equivalent of F
1 F = approximately 1 F.
Recorded scale factors: 1 for F; 1 for F.
Worked example
Known input: 10 F. Reference equivalent: 10 F. The return conversion gives approximately 10 F.
The calculation preserves the capacitance quantity.
Common reference values
| Input (F) | Reference equivalent (F) |
|---|---|
| 1 | 1 |
| 5 | 5 |
| 10 | 10 |
| 25 | 25 |
| 50 | 50 |
| 100 | 100 |
Compare one F with other units
| Target unit | Equivalent of 1 F | Definition guide |
|---|---|---|
| Millifarads (mF) | 1000 | Read definition |
| Microfarads (µF) | 1000000 | Read definition |
| Nanofarads (nF) | 1000000000 | Read definition |
| Picofarads (pF) | 1000000000000 | Read definition |
| Femtofarads (fF) | 1000000000000000 | Read definition |
One coulomb per volt
The farad (F) is the SI unit of capacitance, defined as the capacitance of a capacitor that stores one coulomb of charge when one volt is applied across it, so 1 F = 1 C/V. In base units that is 1 s⁴·A²·m⁻²·kg⁻¹. The unit honors Michael Faraday, and the SI Brochure lists it as a coherent derived unit with a special name. It was adopted as a practical electrical unit in the early 1880s at the International Electrical Congress in Paris, and it is a very large unit for most components. A capacitor of 1 F is a specialist part, a supercapacitor, while ordinary circuits use millionths to trillionths of a farad.
Prefixes that cover real components
Practical capacitors are labeled with prefixes. A microfarad (µF) is 10⁻⁶ F and a nanofarad (nF) is 10⁻⁹ F. A picofarad (pF) is 10⁻¹² F, and a femtofarad (fF) is 10⁻¹⁵ F. A decoupling capacitor next to a microchip is often 100 nF, written 0.1 µF. Radio tuning capacitors run from a few pF to hundreds of pF. Large aluminum electrolytic capacitors in power supplies go from 100 µF to several thousand µF, and supercapacitors reach from 1 F to thousands of farads. Because each step is 1,000 times the previous one, converting between neighbors means moving the decimal point three places, and between µF and pF it means six.
Reading capacitor markings
Small ceramic capacitors carry a three-digit code in picofarads, where the first two digits are the value and the third is the number of zeros. A part marked 104 is 10 followed by four zeros, which is 100,000 pF, equal to 100 nF or 0.1 µF. A part marked 473 is 47,000 pF, or 47 nF. Older parts may show µF as mfd or MFD, which means microfarad and not millifarad, since the old notation used M for thousand. Letters after the code give tolerance and voltage ratings that are separate from the capacitance. A converter changes only the unit of the stated value and does not decode these ratings.
Energy and charge stored
The energy stored in a capacitor is E = ½ C V², and the charge is Q = C V. A 1,000 µF capacitor charged to 12 V holds 0.5 × 0.001 × 144 = 0.072 J and a charge of 0.012 C. A 1 F supercapacitor at 5 V stores 12.5 J and 5 C, similar in energy to lifting a 1 kg mass by about 1.3 m. Because energy grows with the square of voltage, doubling the voltage rating quadruples the stored energy for the same capacitance. A capacitor holds much less energy per kilogram than a battery, but it can release it quickly, which is its role in flash circuits and power buffering.
Time constants and reactance
Capacitance sets timing and filtering behavior. In an RC circuit, the time constant is the resistance in ohms times the capacitance in farads, giving seconds: 10 kΩ with 100 µF gives 1 s, and the capacitor reaches about 63 percent of the supply in that time. For alternating current, the reactance is 1 / (2π f C). A 1 µF capacitor at 50 Hz has a reactance of about 3,183 Ω, and at 1 kHz about 159 Ω. These relations need the capacitance in farads, so a value read in µF or nF must be converted with the correct power of ten, and a slip of a factor of 1,000 changes the answer by that factor.
Series and parallel combinations
Capacitors in parallel add: 10 µF and 22 µF make 32 µF. In series, the reciprocals add, so two 10 µF capacitors in series give 5 µF, and 10 µF with 22 µF gives 6.875 µF. This is the opposite of resistors. Parallel combinations raise capacitance and keep the voltage rating of the weakest part, while series combinations lower capacitance and raise the usable voltage if the voltages share evenly, which in practice requires balancing resistors for electrolytics. The unit conversion step comes first: all values must be in the same unit, either µF or F, before the formulas apply. Mixing 4.7 µF with 220 nF, for instance, requires writing both as 4.7 µF and 0.22 µF, so the parallel total is 4.92 µF, and the series total is 4.7 × 0.22 / 4.92 = 0.210 µF.
Supercapacitors and very large values
Electric double-layer capacitors, often called supercapacitors, offer capacitance from fractions of a farad up to several thousand farads, usually at low voltage ratings of 2.5 to 3 V per cell. A 3,000 F cell at 2.7 V stores 0.5 × 3,000 × 2.7² = 10,935 J, about 3 Wh. They are used for energy recovery, backup power and short bursts. Their values appear in farads directly, which is why a converter has to cope with values spanning many orders of magnitude, from femtofarads to thousands of farads. Capacitance of real devices changes with voltage, temperature and age, so a rated value is a nominal figure that comes with a tolerance.
Working a filter and a hold-up example
Two short cases show the unit at work. A first-order low-pass filter with a 1.6 kΩ resistor and a 100 nF capacitor has a cutoff frequency of 1 / (2π × 1,600 × 10⁻⁷), about 995 Hz. Entering 100 nF as 0.1 µF or 10⁻⁷ F gives the same result, which is a quick check that the prefix was handled correctly. For hold-up energy, a 4,700 µF capacitor falling from 12 V to 9 V releases 0.5 × 0.0047 × (144 − 81) = 0.148 J. A load drawing 0.5 W would be supplied for about 0.3 s, before accounting for the circuit that is regulating the voltage.
Notation conventions and mix-ups
The symbol is F, in upper case because it comes from a person name, and prefixes attach directly, as in pF and µF. The symbol for micro is the Greek mu, though uF is common in plain text and on schematics. Capital M means mega, so mF is millifarad and MF would be a megafarad, which does not exist as a real component, and writing mF where µF is meant overstates a capacitor by a factor of 1,000. Do not confuse F with the Fahrenheit symbol °F or with force. Another notation trap is the unit named farad per meter (F/m), used for permittivity, where the vacuum value is about 8.854 × 10⁻¹² F/m. The same symbol appears with a different meaning, so read the full unit.
Precision and checking
- Keep source capacitance precision.
- Retain any tolerance stated by the source.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Capacitance converter
- Farads to Microfarads converter
- Farads to Nanofarads converter
- Farads to Millifarads converter
- Farads to Picofarads converter
- Farads to Femtofarads converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.