Where picofarads are the natural unit

Radio-frequency circuits, oscillators, oscilloscope probes, coaxial cables and touch sensors all work with capacitances of a few picofarads to a few hundred. A crystal load capacitor of 18 pF, a trimmer set near 30 pF, or the input capacitance of a scope probe near 10 pF are everyday values in electronics. The farad answers in these cases come out with eleven leading zeros, for example when an electrostatics formula returns 2.2 × 10^−11 F. This page turns that result into picofarads so it can be compared with the values in an RF data sheet. Radio amateurs, firmware engineers tuning an oscillator and students checking a lab report all meet the same step. Hobbyists building receivers from older books meet the same conversion when a table lists the tuning capacitor in farads.

Twelve places and the prefix pico

Pico stands for 10^−12, so 1 pF is 0.000000000001 F and 1 F is 1,000,000,000,000 pF. Going from farads to picofarads shifts the decimal point twelve places to the right. The relationship is fixed by the SI prefix definitions in the BIPM SI Brochure. Lowercase p marks pico, and the symbol should not be confused with uppercase P for peta, which is 10^15. Older documents sometimes write micro-microfarad, abbreviated µµF, for the picofarad. If you meet that notation, it means the same thing as pF. Also watch for lowercase p written as P in careless plain text, where only the context shows that pico was intended.

Reading the 10 F default

With 10 F entered, the page displays 10,000,000,000,000, ten trillion pF. As a physical statement, it is meaningless for a signal capacitor but it illustrates the size of the step. A better test value is 0.000000000022 F, which converts to 22 pF, a typical load capacitor for an 8 MHz crystal. Try 0.0000000001 F next, which gives 100 pF, a size often used in RF coupling and filters. Entering the zeros correctly takes care, so read the number back, or compare the result with an estimate before relying on it. A mistyped zero turns 22 pF into 220 pF or 2.2 pF, which is a different crystal load altogether.

Coaxial cable and probe capacitance

Cable capacitance is quoted per unit length. A common 50 Ω coaxial cable has a capacitance on the order of 100 pF per meter, so a 3 m run adds roughly 300 pF, which is 3 × 10^−10 F. For a high-impedance signal source, that extra capacitance can load the signal and reduce bandwidth. Oscilloscope probes use a 10:1 divider to cut their input capacitance to about 10 to 15 pF, and the compensation capacitor in the probe is adjusted to match the scope input. These are typical magnitudes, so use the datasheet for the exact cable or probe. Longer runs also raise the load on the driver, so the capacitance sets how fast a signal edge can travel along the cable. Foam and solid dielectrics also differ, which is why two cables of the same impedance can differ in picofarads per meter.

Crystal load capacitors

A quartz crystal specifies a load capacitance, often 12 pF, 18 pF or 20 pF, that the circuit must present for the crystal to oscillate on frequency. In a Pierce oscillator, two capacitors C1 and C2 on each side of the crystal combine in series, and stray capacitance on the board adds to the total. With C1 = C2 = 22 pF and about 4 pF of stray capacitance, the effective load is 22/2 + 4 = 15 pF. Many application notes suggest assuming a few picofarads of stray capacitance when the real value is unknown. If you compute the target in farads, 1.5 × 10^−11 F, this page gives you the picofarad figure to compare with the crystal datasheet.

Small fractions of a picofarad

Some capacitances fall below one picofarad, such as the stray capacitance between adjacent board traces or across the open contacts of a relay. A value of 0.47 pF is 4.7 × 10^−13 F, and the page returns 0.47 when you enter 0.00000000000047 F. At this size the units on the datasheet may switch to femtofarads, since 1 pF is 1,000 fF, and 0.47 pF is 470 fF. Parasitic capacitance is hard to measure and depends on layout, so expect uncertainty far larger than the digits of the converted number suggest.

A parallel-plate estimate in picofarads

The capacitance of two parallel plates is C = ε₀ × A / d in air, with ε₀ about 8.854 × 10^−12 F/m. Two plates of 1 cm² (10^−4 m²) separated by 1 mm (10^−3 m) give C = 8.854 × 10^−12 × 10^−4 / 10^−3 = 8.854 × 10^−13 F, which is 0.8854 pF. Halve the gap and the capacitance doubles to about 1.77 pF. This is the scale of a small touch electrode or a probe tip, and it explains why bringing a hand near a sensing pad changes the value by a fraction of a picofarad. Entering 0.0000000000008854 into the page confirms the figure. The estimate neglects fringing fields at the plate edges, which add a few percent for small plates.

Going back to farads

Select pF as the From unit and farads as the To unit to reverse the conversion. A value of 100 pF is 1 × 10^−10 F, and 12 pF is 1.2 × 10^−11 F. A formula that expects farads, such as the capacitive reactance 1/(2πfC), needs the long form. At 10 MHz, a 100 pF capacitor has a reactance of about 159 Ω, which you can check by entering C = 1 × 10^−10 F. An inductor of 1 µH with 100 pF resonates near 15.9 MHz, another formula that wants farads. Using 100 directly would produce a reactance of 1.6 × 10^−10 ohms, off by twelve orders of magnitude.

What the number does and does not settle

The converter changes the unit of a capacitance and nothing else. Small ceramic capacitors have tolerances such as ±5 percent, ±0.25 pF or ±0.5 pF, which matters more than any rounding at these values, and the voltage coefficient and temperature coefficient of the dielectric also shift the value. The page does not calculate installation limits, equipment ratings, protection, material response or compliance, and it does not choose parts for a design. A part marked 22 pF ±5 percent can fall anywhere from 20.9 to 23.1 pF.