Measurement basis
A converted capacitance value alone does not specify stored energy; voltage is also needed for that relationship.
Definition conventions
Prefixes use SI decimal powers, and conversions remain within capacitance.
Conversion method
Use the compatible farad-factor ratio for the known capacitance value.
Choose the conversion direction
Confirm F and its source prefix before selecting the target capacitance scale.
One farad as one coulomb per volt
Capacitance describes how much electric charge a component stores for each volt across it. The SI unit is the farad (F), defined as one coulomb per volt, and it is named after Michael Faraday. In base units one farad is s⁴·A²/(kg·m²), which nobody uses in practice. The farad turns out to be an enormous unit for ordinary electronics. Components on a circuit board are measured in picofarads, nanofarads and microfarads, with each prefix a factor of 1,000 apart: 1 µF is 1,000 nF and 1,000,000 pF. A value of 4.7 µF equals 4,700 nF, and 22 pF equals 0.022 nF. The unit tells you the charge per volt, so a 100 µF capacitor holds 100 microcoulombs at one volt and 1.2 millicoulombs at 12 V.
Reading three-digit capacitor codes
Small ceramic capacitors often carry a three-digit code in place of a printed value. The first two digits are significant figures and the third is a multiplier, and the result is in picofarads. A part marked 104 is 10 followed by four zeros, 100,000 pF, which is 100 nF or 0.1 µF. A part marked 473 is 47,000 pF, or 47 nF, and 222 is 2,200 pF, or 2.2 nF. A letter after the code gives the tolerance, for example J for 5 percent and K for 10 percent. The code is a frequent source of off-by-1,000 errors, since 104 is often misread as 10 pF. Converting to nanofarads first, where most hobby circuits are specified, makes a sanity check easy.
Typical ranges for real components
Different capacitor types cover different parts of the scale. Ceramic multilayer capacitors range from about 1 pF to around 100 µF, film capacitors from a few nanofarads to tens of microfarads, and aluminum electrolytics from about 1 µF to tens of millifarads. Supercapacitors, also called electric double-layer capacitors, reach hundreds or thousands of farads in a single cell but operate only at a few volts, typically 2.7 V. At the small end, the parasitic capacitance of a touchscreen sensing node or a transistor gate is measured in femtofarads. One femtofarad is 10⁻¹⁵ F, so 1 pF is 1,000 fF. Picking the right prefix keeps numbers short: 0.000000047 F is more readable as 47 nF.
Time constants and a worked RC example
Capacitance usually appears together with resistance. A resistor of 10 kΩ charging a 100 nF capacitor has a time constant of R × C = 10,000 Ω × 100 × 10⁻⁹ F = 1 ms. After one time constant the capacitor voltage reaches about 63 percent of the supply, and after five it is within about 1 percent. Converting 100 nF to 0.1 µF changes nothing about the physics, but the prefix mix must stay consistent: kΩ with µF gives milliseconds directly, because 10⁻⁶ times 10³ is 10⁻³. This is the reason many designers pair kilohm with microfarad or megohm with nanofarad in timing circuits. A unit mix that yields seconds or milliseconds without extra factors reduces slips.
Energy stored in a capacitor
The energy in a charged capacitor is ½ × C × V². A 1 F supercapacitor charged to 5 V holds 12.5 J, and a 470 µF electrolytic charged to 25 V stores about 0.147 J. Doubling the voltage quadruples the energy, which is why voltage rating matters more than capacitance alone. The stored energy of an ordinary capacitor is modest. One watt-hour is 3,600 J, so 12.5 J is about 3.5 mWh, far below what a battery of similar size holds. Capacitors excel at delivering energy quickly, as in camera flashes or power supply filtering, not at storing it for long periods. Rated voltage, tolerance, temperature coefficient and leakage current are separate specifications that no capacitance conversion can check.
Marking styles and common symbol confusion
The Greek letter mu is the standard prefix symbol, so microfarad is µF, but ASCII text often uses uF. HVAC capacitor labels frequently print MFD, an old abbreviation that means microfarads, not millifarads, and MF can look like megafarads when it is not. Strictly, M is mega and m is milli, which makes mF a thousandth of a farad and MF a million farads, a value no component has. Some older schematics use µµF for picofarad, since 1 µµF is 10⁻¹² F. When the case printing is ambiguous, check the datasheet or measure with a capacitance meter, and write the unit in full during conversions to prevent a misreading from creeping into a calculation.
Parallel, series and the effect on totals
Capacitors in parallel add: 10 µF plus 22 µF gives 32 µF. In series the reciprocals add, so 10 µF in series with 10 µF is 5 µF, and 1 µF in series with 100 nF is about 91 nF. This is the opposite of resistance. Converting all values to the same unit before combining avoids errors, for instance by expressing everything in nanofarads. Real capacitors also have equivalent series resistance and inductance that limit performance at high frequency, and electrolytics lose capacitance with age and heat. A converter can restate a nominal value in another unit. It does not account for tolerance, which can be as wide as minus 20 and plus 80 percent for some electrolytic types.
Where the definitions come from
The farad as coulomb per volt is stated in the BIPM SI Brochure as a derived unit with a special name, and NIST Special Publication 811 gives the same definition. Since the 2019 redefinition of SI the coulomb is tied to the exact value of the elementary charge, 1.602176634 × 10⁻¹⁹ C, so the farad inherits an exact link to fundamental constants, though practical capacitance standards are realized with calculable capacitors maintained by national metrology institutes. Component manufacturers follow IEC 60062 for marking codes, which is the standard behind the letter tolerance codes. For design work, rely on the manufacturer datasheet for tolerance, voltage rating and temperature behavior, and use unit conversion only to restate a known value in a more convenient prefix.
Decoupling and bulk capacitors on a supply rail
A typical microcontroller board places a 100 nF ceramic capacitor beside each supply pin and one or more larger capacitors, often 10 µF, near the regulator. The small part supplies fast current pulses with very little series inductance, and the large part covers slower changes. Their values differ by a factor of 100, so the datasheet usually lists them in different prefixes, nF for one and µF for the other. Treat 0.1 µF and 100 nF as the same part. A schematic that lists 0.1u, 100n and 104 for three capacitors is describing a single value three ways, and a parts list should settle on one notation to avoid ordering mistakes.
Precision and checking
- Keep the precision of the source capacitance.
- Retain the prefix on the farad symbol when saving the output.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Choose a unit definition
Farads (F)
Definition, reference values and linked conversions.
Millifarads (mF)
Definition, reference values and linked conversions.
Microfarads (µF)
Definition, reference values and linked conversions.
Nanofarads (nF)
Definition, reference values and linked conversions.
Picofarads (pF)
Definition, reference values and linked conversions.
Femtofarads (fF)
Definition, reference values and linked conversions.
Use a working converter
- Capacitance converter
- Microfarads to Farads converter
- Farads to Microfarads converter
- Microfarads to Millifarads converter
- Millifarads to Microfarads converter
- Microfarads to Nanofarads converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.