Cans are marked in microfarads

Large aluminum electrolytic capacitors are labeled in microfarads, even when the value is in the thousands. A part marked 4700 µF is 4.7 mF, and a design note that gives the requirement in millifarads has to be translated before you can shop for the part. The formula on the page is µF = mF × 1,000, so 10 mF becomes 10,000 µF. The two units are neighbors on the prefix ladder, and the conversion is a three-place decimal shift. Having it on a page saves a moment of doubt at a parts counter or when reading a schematic that mixes styles, such as one that lists 2.2 mF next to 470 µF. The same need arises for a hobbyist rebuilding a guitar amplifier or a bench supply from a published design, where the original article gives a value in one unit and the supplier's catalog lists parts in another.

Reading the default of 10 mF

The default entry of 10 mF returns 10,000 µF. That is a big electrolytic, the kind found in a bench power supply or an amplifier. If you type 4.7, the page returns 4,700, matching the common 4700 µF value. A value of 2.2 mF returns 2,200 µF and 0.33 mF returns 330 µF. Because microfarads are smaller, the number gets bigger, and a result that is smaller than the input means the menus are reversed. The usual way to double-check is to move the decimal point three places to the right and compare it with the output. Entering a value with several decimals, such as 0.047, returns 47, and a whole number such as 22 returns 22,000. If a part's can is marked 22000 µF, that is 22 mF, a capacitor of the size used in large audio and welding-related supplies.

Sizing a smoothing capacitor

In a mains-frequency supply with a full-wave rectifier, the ripple voltage on the reservoir capacitor is roughly ΔV = I / (f × C), where f is the ripple frequency. For a 1 A load and a ripple frequency of 100 Hz, which is typical for a 50 Hz mains, a 4.7 mF capacitor gives about 1 / (100 × 0.0047) = 2.13 V of ripple. The formula needs C in farads, so a 4,700 µF part has to be written as 0.0047 F. The page helps with the step before that one by moving between mF and µF, so the value in the parts list agrees with the value in the calculation. The figures are an illustrative approximation, not a design recommendation. Doubling the capacitor to 9.4 mF halves the ripple to about 1.06 V at the same load, and the same arithmetic in microfarads would use 9,400 µF. The approximation ignores the conduction angle of the diodes and the resistance of the transformer, so a real supply deserves a proper simulation or a bench measurement.

Audio amplifiers and crossover parts

Audio equipment uses capacitors across the range. Power supply reservoirs in amplifiers might be several millifarads, while coupling and crossover parts are mostly in the microfarad range. A designer comparing a 6.8 mF reservoir with a 47 µF coupling capacitor sees at once that the first is 6,800 µF, which is about 145 times larger than the second. That ratio explains the very different roles: one stores energy for peaks in demand, the other blocks DC and passes signals. The converter makes the comparison direct by putting both values in the same unit.

Old markings such as MFD

Older equipment and some catalogs use MFD or mfd for microfarad. An MFD marking is not a millifarad, and the lowercase m in mfd also stands for micro in that convention. A part marked 2200 MFD is therefore 2,200 µF, which is 2.2 mF. If a service manual from the 1970s lists a capacitor as 5000 MFD, the modern equivalent is 5,000 µF, or 5 mF. Use the page to confirm that a replacement part's value matches the original, and check the voltage rating separately, since it is a property that this converter does not address.

Parallel and series combinations

Capacitors in parallel add their values, so 4,700 µF and 2,200 µF in parallel give 6,900 µF, or 6.9 mF. In series the reciprocals add, so two 10 mF capacitors in series give 5 mF, or 5,000 µF. Doing the arithmetic in microfarads and converting at the end keeps the numbers manageable, and the page confirms that 6,900 µF is 6.9 mF. Series connection also splits the voltage between the parts, and it only does so evenly if balancing resistors are used, which is a design question outside this converter.

Tolerance and aging

Electrolytic capacitors have wide tolerances, often 20 percent, and their capacitance drifts with temperature and age. A nominal 4,700 µF part may measure between about 3,760 and 5,640 µF new, which is 3.76 to 5.64 mF. Quoting more significant figures than the tolerance supports is misleading, so round the converted value accordingly. If a measured value is far outside the tolerance band, the part may be failing. A capacitance meter reading in µF can be entered here to see the same value in mF for a report or a log. Technicians who test old equipment compare the measured value with the nominal one and treat a drop of more than a fifth below the label as a sign of aging. For a 4,700 µF part, that limit is about 3,760 µF, or 3.76 mF.

Going from microfarads to millifarads

To convert the other way, swap the menus. The page divides by 1,000, so 4,700 µF returns 4.7 mF and 100 µF returns 0.1 mF. This direction is useful when a datasheet lists a large value in microfarads and you want it in the unit that your simulation or calculation uses. A result with trailing zeros after the decimal point can be written without them. As always, check that the number moves in the direction you expect, and compare it with the part's physical size, since larger values generally mean larger cans.

Ripple current and ESR for large capacitors

The page converts the unit of a capacitance value and does nothing else. It does not model equivalent series resistance, ripple current rating, leakage, temperature or aging, and it does not evaluate installation limits, equipment ratings, protection or compliance. Large capacitors can hold a dangerous charge after power is removed, so follow the manufacturer's instructions and the applicable safety rules when handling them.