When a battery label becomes a physics problem

A battery label gives capacity in mAh, but the equations in a physics or chemistry course use coulombs. Students who need the charge that flows through a circuit, engineers checking a coulomb-counting fuel gauge, and hobbyists doing electroplating all hit the same gap. This page converts the charge from the engineering unit to the SI unit. The coulomb is the SI unit of electric charge, equal to one ampere second, and the value you get can drop into formulas such as Q = I × t or Q = C × V. The page converts the unit and leaves the interpretation of the battery, including its voltage and usable fraction, to you.

Why the factor is 3.6

One milliampere is 0.001 A, and one ampere equals one coulomb per second. An hour has 3,600 seconds. Multiplying 0.001 C/s by 3,600 s gives 3.6 C, so C = mAh × 3.6. The default input of 10 mAh returns 36 C. The relation is exact, since the ampere, the second and the SI prefix are all defined quantities in the SI Brochure. Reverse the conversion by dividing by 3.6, so 36 C returns 10 mAh. If your calculator gives 3,600 for a mAh value, you applied the factor for ampere hours by mistake, which is off by exactly 1,000. The conversion is linear, so doubling the capacity doubles the charge, and two cells in parallel hold the sum of their coulombs. That makes the page useful for adding up a bank of cells whose labels are all in mAh before the total goes into a coulomb-based formula.

Charge in a typical phone battery

A 2,000 mAh battery holds 7,200 C. A 500 mAh wearable cell holds 1,800 C, and a tiny 0.5 mAh memory-backup cell holds 1.8 C. Numbers in the thousands of coulombs can feel large, but a coulomb is a small amount of charge compared with what a battery stores. The figure matters in textbook problems that ask how many electrons pass through a circuit, because the count is the charge divided by the elementary charge, which is 1.602176634 × 10⁻¹⁹ C exactly. One mAh therefore corresponds to about 2.247 × 10²² electrons moving past a point.

Electroplating and electrolysis arithmetic

Faraday constant, 96,485.33212 C per mole of electrons, links charge to chemical change. Dividing by 3.6 gives about 26,801 mAh per mole of electrons, or 26.8 Ah. A hobby plating bath run at 500 mA for two hours passes 1,000 mAh, which is 3,600 C, or about 0.0373 mole of electrons. That is the charge available for depositing metal, before accounting for efficiency losses at the electrode. Convert the cell current and time to coulombs first, then use the chemical equation for the metal in question. The page performs the unit step, and the stoichiometry stays in your own working.

Capacitor energy storage versus battery charge

Capacitors are specified in farads, and the charge they hold is Q = C × V. A 1 F supercapacitor charged to 5 V holds 5 C, which converts to 5 / 3.6 = 1.389 mAh. That is a small fraction of a smartphone battery, and the capacitor delivers it as its voltage falls rather than at a steady level. Comparing in coulombs, or in mAh, shows quickly how much charge a backup capacitor supplies relative to a coin cell. Use the reverse direction for this check, entering coulombs and choosing mAh as the target.

Reading coulombs from a current log

A data logger that records current in amperes at fixed time steps yields charge by summing current times seconds. If the log shows an average of 0.25 A over 1,800 seconds, the charge is 450 C, which is 125 mAh. Logs in milliamperes need the same care as labels: 250 mA × 1,800 s gives 450,000 mC, or 450 C. The converter lets you move from the coulomb total to a capacity figure and compare it with the nominal rating of the battery. If a test drew 125 mAh from a cell labeled 500 mAh, the test used a quarter of the label capacity.

Tracing a slip in the result

Since the factor is a clean 3.6, a result that is about three and a half times the input is the correct size. A result of 3,600 times the input means the hour was converted but the milli- prefix was ignored, and a result of 0.0036 times the input means the factor was inverted twice. Keep a quick anchor in your head: 1 mAh is 3.6 C, so 1,000 mAh is 3,600 C. For longer inputs the page shows up to 12 significant digits, enough for any label figure, and rounding differences are negligible against the tolerance of a real cell.

Labeled capacity versus delivered charge

The page restates a battery label in coulombs. The discharge curve in the cell's data sheet, not this page, shows whether a battery will actually deliver its labeled charge. Real cells deliver less at high currents and low temperatures, for example a power tool pack on a cold morning. Use the coulomb figure for the arithmetic of a lab report or a design estimate, and consult the datasheet and the safety guidance for the device when the work involves charging, protection or hardware that could fail. A converted number from a rounded label also carries the rounding of the label. A cell marked 2,000 mAh may really hold 1,950 or 2,100 mAh when new, which is 7,020 C or 7,560 C, and a result stated to six digits would imply a precision that the starting value never had.

Short current pulses in coulombs

Events that last a fraction of a second are naturally described by the charge they move. A motor start that draws 2 A for 100 ms moves 0.2 C, which is 0.2 / 3.6 = 0.0556 mAh. That is a tiny bite out of a 2,000 mAh battery, so thousands of such starts are needed before the pulses matter, though the peak current may still strain the cell and its wiring. A sensor that transmits for 50 ms at 120 mA moves 6 mC, and an hourly schedule of those bursts adds up to 144 mC in a day. Converting each burst to coulombs and summing them gives a daily charge that you can divide by 3.6 to see how many mAh it costs.