Bridging physics homework and battery labels
Coulombs belong to physics and electrochemistry, while milliampere hours belong to the batteries in phones, earbuds, flashlights and power banks. People who convert between them are usually students checking a charge calculation against a product label, or hobbyists comparing a measured charge, for example from a coulomb counter, with a rated capacity. The two units measure the same kind of quantity, electric charge, and differ only in the time base. One is built on the second and the other on the hour. This page does the translation in a single step so you can see directly how many milliampere hours a given number of coulombs represents, or the reverse by swapping the menus.
Where 3.6 comes from
One ampere flowing for one second is one coulomb. One milliampere is a thousandth of an ampere, and one hour is 3,600 seconds. Multiplying gives 0.001 A × 3,600 s = 3.6 C for each milliampere hour. The page therefore uses mAh = C / 3.6, written in the formula as C × 0.277777777778. The conversion is exact apart from the repeating decimal. Going back, C = mAh × 3.6. Because the hour is a non-SI unit accepted for use with the SI, as listed in the BIPM SI Brochure, the ampere hour carries a definition tied to the second, and there is no separate experimental factor to look up.
The default 10 C
Ten coulombs equals 10 / 3.6 = 2.7778 mAh. The engine returns 2.7777777777777777 before rounding, which is the repeating decimal 2.777... cut off by floating point. That is a small capacity, comparable with a very small button cell or a tiny fraction of a smartphone battery. One coulomb is 0.2778 mAh, 7.2 C is exactly 2 mAh, and 100 C is about 27.78 mAh. A useful memory aid is that 3.6 C equals 1 mAh, so a charge in coulombs is a little under four times its milliampere hour value. If you see a result larger than the coulomb input, you probably chose the wrong direction in the menus.
From a battery label to coulombs
Run the conversion backward for a real product. A 3,000 mAh phone battery equals 3,000 × 3.6 = 10,800 C. A 500 mAh coin-sized lithium cell holds 1,800 C. A small 2.5 mAh hearing-aid style cell holds 9 C. Those results come from the factor alone and say nothing about whether the cell can deliver that charge at a given current. Cells also lose capacity as they age, so a battery that started at 3,000 mAh may deliver 2,500 mAh after a few hundred cycles. Rated capacity usually applies to a specified discharge rate, cutoff voltage and temperature. A battery rated for 3,000 mAh at a gentle discharge may deliver less under a heavy load, so the coulomb value is a nominal total and not a promise of runtime.
Charge is not energy
People often try to compare a milliampere hour rating directly with watt hours, and the two quantities are different. Charge in coulombs or milliampere hours tells you how much electric charge a cell can move. Energy also depends on voltage. A 3,000 mAh cell at a nominal 3.7 V stores about 11.1 Wh, while a 3,000 mAh pack at 7.4 V stores about 22.2 Wh, even though both carry 10,800 C. This page ignores voltage entirely, so use it when you need charge. If you want energy, multiply the capacity in ampere hours by the nominal voltage in a separate step, and note that nominal voltage is only an average over the discharge.
Coulomb counters and test equipment
Battery testers and some power-monitoring chips integrate current over time and report charge in coulombs, milliampere hours or both. A gauge that logs 1,800 C over a discharge has seen 500 mAh pass through it. Comparing a logged value with a rated capacity gives a rough idea of how much of the rating you actually obtained, although efficiency, temperature and cutoff voltage all affect the result. When you compare, convert both to the same unit and keep the same number of significant figures. A rated 2,000 mAh against a measured 7,000 C, which is 1,944.4 mAh, differs by about 2.8 percent, a gap that is smaller than the typical measurement uncertainty of many hobby testers.
Power banks and logged charge
Physics courses sometimes ask how many coulombs a power bank holds. A 10,000 mAh bank rated at its cell level holds 36,000 C, while a 20,000 mAh bank holds 72,000 C. Dividing by 3.6 takes you back. The figures are nominal ratings, and the usable output of a bank is lower because of conversion losses and the voltage boost circuitry. If you want the charge that actually reaches a device, use measured values rather than the label. The conversion here remains exact for whichever charge number you supply, and the choice of rated or measured input is yours. Fuel-gauge chips and bench logging meters often accumulate charge in counts that map to coulombs or microampere hours. If a log shows 5,400 C for a discharge, dividing by 3.6 gives 1,500 mAh. Logs recorded separately for charge and discharge can be compared in the same unit by converting both with this page, which makes the round-trip efficiency easy to see as a ratio of two numbers in one unit.
Repeating decimals in capacity labels
The engine works in double precision,and many results are repeating decimals such as 2.7777777777777777 mAh for 10 C. For most uses, two decimal places are plenty. Capacity labels are generally given as whole milliampere hours, so rounding 27.7778 to 27.78 or even 28 is consistent with how manufacturers print them. In calculations that feed other steps, keep the unrounded value until the last stage so rounding does not accumulate. When you convert from milliampere hours to coulombs, results are exact multiples of 3.6, so they rarely need rounding at all.
What the page does not tell you
This conversion states the same charge in a different unit. It does not predict runtime, battery life, charging time, safe current, cell aging or compliance with a battery standard. Labeled capacity is a nominal figure measured under test conditions defined by the manufacturer or a standard, and real use differs. Pick the correct units in both menus and read both labels again before copying the output. Treat the output as a restatement of charge, and consult the battery datasheet for discharge limits and handling guidance.